1 / 13

Overview of EPA-recognized Total Mercury (Hg) Test Methods

Overview of EPA-recognized Total Mercury (Hg) Test Methods. Bill Grimley OAQPS grimley.william@epa.gov (919) 541-1065 Robin Segall OAQPS segall.robin@epa.gov (919) 541-0893 Jeff Ryan ORD ryan.jeff@epa.gov

vartan
Télécharger la présentation

Overview of EPA-recognized Total Mercury (Hg) Test Methods

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Overview of EPA-recognized Total Mercury (Hg) Test Methods BillGrimley OAQPS grimley.william@epa.gov (919) 541-1065 Robin Segall OAQPS segall.robin@epa.gov (919) 541-0893 Jeff Ryan ORD ryan.jeff@epa.gov (919) 541-1437

  2. Topics • EPA total Hg test methods • Method 101A • http://www.epa.gov/ttn/emc/promgate/m-101a.pdf • Method 29 • http://www.epa.gov/ttn/emc/promgate/m-29.pdf • Other recognized total Hg method(s) • ASTM D 6784-02 Also known as Ontario Hydro Method • http://www.astm.org/Standards/D6784.htm • Potentially useable method • Method 30B • http://www.epa.gov/ttn/emc/promgate/Meth30B.pdf • Measurement considerations • Traversing • Paired trains

  3. What is Total Hg ? Sum of speciation fractions, defined as follows: • HgP : Particulate-bound Hg • Hg+2 : Oxidized forms of gaseous Hg(HgCl2, HgO, Hg(NO3)2?, HgSO4?) Hg0 : Elemental gaseous Hg • HgT (Total) = HgP + Hg+2 + Hg0 • Generally, what is measured by Methods 101A, 29, and ASTM D6784-02 • HgTG (Total Gaseous) = Hg+2 + Hg0 • Generally ,what is measured by Hg CEMS and PS-12B (sorbent trap)

  4. Why We Want to Measure Total Hg … • Determine compliance with total Hg emission limits • Also: • Characterize a source’s emissions • Evaluate control technology performance • Process control

  5. Manual Total Hg Methods … • Normally used for periodic determinations of source category emission compliance • Typically 1-2 hour long “snap shots” • Must be traversed • Expensive, labor intensive, delayed results

  6. EPA Method 101A (Hg Part.) (Total Gaseous Hg)

  7. EPA Method 29 (Hg Part.) (Total Gaseous Hg) (Total Gaseous Hg)

  8. ASTM D6784-02 (Total and SpeciatedHg) (Hg Part.) (Oxidized Hg) (Elemental Hg) (Elemental Hg)

  9. ASTM D6784-02 Total Hg Speciation Method • Has been used in previous EPA efforts (ICR) to characterize Hg emissions from US coal-fired electric utilities • Optimum characterization requires speciated Hg measurements at Pollution Control Device (PCD) inlet and outlet locations

  10. QA/QC DifferencesEPA Method 29 ASTM D6784-02 • Replacements needed: • Sections 7.5.33 and 11.1.3 (Prep of stds; sample analysis) • Section 9.2.3 (QA/QC procedures) _________________________ • Optional replacements: • 8.2.8 & 8.2.9.1 • 8.2.9.2 & 8.2.9.3 • 8.3.4 • 8.3.5 • Use instead: • Sections 13.4.1.1 thru 13.4.1.3 • Section 13.4.2 ___________________ may replace with • 13.2.9.1 thru 13.2.9.3 • 13.2.10.1 thru 13.2.10.4 • either 13.3.4 or 13.3.6 • either 13.3.5 or 13.3.6

  11. Other Sampling Techniques • EPA Method 30B: The “Sorbent Trap Reference Method” : Hg (TG) +? Potential for non-isokinetic biases, but method might be included as regulatory option, with conditions/modifications Capable of both speciated and total gaseous Hg measurements

  12. Sorbent Trap Sampling Train Sample Console

  13. Summary • All Mercury methods: • Added detail (vs. Method 5) • Added effort ( ditto ) • Produce results of demonstrated accuracy and precision

More Related