1 / 18

Objectives

Objectives. Efficacy Safety Adverse effects Copper intrauterine device(IUD) LNG-releasing intrauterine devices(LONG-IUS). Methods. Retrospective manner of 8410 women who had received a IUD in FPC from January 1983 to December 2005.

vonda
Télécharger la présentation

Objectives

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Objectives • Efficacy • Safety • Adverse effects Copper intrauterine device(IUD) LNG-releasing intrauterine devices(LONG-IUS)

  2. Methods • Retrospective manner of 8410 women who had received a IUD in FPC from January 1983 to December 2005. • 410 women were excluded: 2.02% (emergency contraception method) and 2.9% (were lost). Therefore, total study population is 8.000 patients. • Patients was selected according to World Health Organization elegibility criteria. • Different types of copper IUD were prescribed according to the length of uterine cavity (measured by transabdominal ultrasound); one type of LNG-IUD was prescribed. 34 years: 2 chilbirth, 16º cicle day Longitudinal diameter Transverse diameter

  3. Model and number of IUDs Insert/ women First IUD 2th IUD 3th IUD Model N % N % N % Copper IUD MLcu250 st. 72 1.5 28 1.2 5 0.8 MLcu250sho 55 1.1 21 0.9 4 0.6 MLcu250min 34 0.7 13 0.5 3 0.4 MLcu373st 93 1.9 36 1.5 7 1.1 MLcu373sho 58 1.2 22 0.9 5 0.8 MLcu373min 17 0.3 7 0.3 2 0.3 Tplata200st 152 3.1 71 2.9 27 4.1 Tplata200min 68 1.4 26 1.0 6 0.9 Tplata373st 353 7.2 182 7.5 45 6.8 Tplata373min 125 2.5 56 2.3 2 0.3 NovaT 558 11.3 274 11.3 48 7.3 Tcu340st 929 18.9 444 18.3 127 19.3 Tcu340min 440 8.9 221 9.1 44 6.7 GyneT380 360 7.3 183 7.6 57 8.7 FlexiT300st 370 7.5 185 7.6 75 11.4 FlexiT300+ 127 2.6 74 3.1 19 2.9 EffiT380st 397 8.1 209 8.6 74 11.2 EffiT380cor 79 1.6 34 1.4 17 2.6 Gynefix 375 7.6 194 8.0 91 13.8 Mirena 260 5.3 140 5.8 0 0 Total 4922 100 2420 100 658 100 61.5% 30.3% 8.2%

  4. All IUDs were inserted during menstruation, prophylactic antibiotics were not used and, innulliparous women vaginal prostaglandins (misoprostol 100 mg) were administered 6- 8 hours before the insertion. • Monitoring visits before 1, 6 and 12 months during the first year, and then annually until the removal of the IUD. • IUDs contraception was mantained up to five years. In women older than 45 years was removed at menopause (at least one year of amenorrhea).

  5. Studied variables: - age - parity - previous contraception method - type of IUD - number of IUD inserted per patient - complications during the insertion - duration of use - causes of removal - adverse effects (dysmenorrhea, bleeding disorders, expulsion, pelvic inflamatory disease, uterine perforation) and efficacy.

  6. Results • Mean age: 30.5 years (18-44) • Parity: Nulliparous 1404 17,6% At least one vaginal delivery 6040 75,5% Caesarean 556 6,9% Total 8000 100%

  7. Number of IUD for women • 1 IUD 4920 61.5% • 2 IUD 2416 30.3% • 3 IUD 664 8.2% Total 8000 100%

  8. Mean Duration of Use of the IUD • First IUD 52 months • Second IUD 36 months • Third IUD 23 months

  9. Previous Contraception Method Method Number % OC 3200 40.0 IUD 1600 20.0 Barrier method 1352 16.9 Natural 952 11.9 None 544 6.8 Others 352 4.4 Total 8000 100

  10. Insertion Complications Number % Without difficulty 7498 93.8 Difficult Insertion 70 0.9 Cervical dilatation 496 6.2 Light to moderate pain 392 4.9 Severe pain 30 0.4 Uterine perforation 0 0.0 Total 8000 100

  11. Complications of IUD use in the first year of follow-up Expulsion 74 (1.04%) P.I.D. 93 (1.3%) Bleeding disorders 357 (5%) Severe dysmenorrhea 35 (0.5%) Good tolerance 6598 (91.9%) Total 7157 (100%) 559 (7.8%)

  12. Complications that forced IUD removal. First and fifth years of follow-up data First year Fifth year (N= 7157) (N = 4225) P.I.D. 78 (1.1%) 63 (1.5%) Severe dysmenorrhea 32 (0.45%) 21 (0.5%) Bleeding disorders 178 (2.5%) 211 (5%) Migrations 0 (0.0%) 3 (0.01%) Total 288 (4%) 298 (7.1%)

  13. Return to fertility after IUD removal in the first year Pregnancy 5353 (74.9%) No Pregnancy 1769 (24.1%) Total 7122 (100%)

  14. Method Efficacy • Five pregnancies accumulated in 5 years: Pearl index/5 years =0.26 • 24 pregnancies accumulated in 22 years: Pearl index/22 years = 0.3

  15. LNG-Releasing IUD, 400 women • Most common adverse effects, were mastodynia • and weight gain both with a rate lower than 1.5%. • - No cases of uterine perforation or pregnancy • occurred. • - Pearl index at five years of follow up was zero.

  16. - Changes of menses. LNG-Releasing IUD, 400 women

  17. Conclusions: * IUD is a safe and effective contraception method in appropriately selected patients. * The rate of return to fertility is high, as is its efficacy (Pearl index equal to 0.3 during the 22 years period of the study). * Adverse effects are rare. Globally, main complications are PID and abnormal bleeding. In contrast, use of LNG-IUD is associated with oligomenorrhea in a percentage of patients, which it could be considerated a favourable effect for women with hypermenorrhea, either secondary to copper intrauterine device use or spontaneous

More Related