Aggregation of primary meters as a single Supply Point

Aggregation of primary meters as a single Supply Point. Examples. A single premises may constitute a single Supply Point.

whitby
Télécharger la présentation

Aggregation of primary meters as a single Supply Point

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Aggregation of primary meters as a single Supply Point

  2. Examples • A single premises may constitute a single Supply Point. • A single premises MUST meet the criteria of owned or occupied by one person and in close geographical proximity and within a common curtilage and serve each other in a useful way. Ownership & Occupation Geographical Proximity ü ü Public House and Landlord residing in upstairs flat , different service Buildings within the same site split only by a footpath û û Supermarket with a subsidiary operating on the same site but a different service Buildings within the same overall site but physically split by a main road.

  3. Examples Common Curtilage Serve Each Other ü ü School and caretakers cottage within the boundary of the school Swimming pool and Gym/Leisure centre, separate buildings but deemed to serve each other. û û University with a number of adjacent houses which it owns. The houses do not have common curtilage with each other. Swimming pool and Library cannot be deemed to serve each other – operate independently and provide different services

  4. Summary • A sample of 84 sites analysed ranging from 2 aggregated meter points to 25 across all AQ bands • For the purposes of this analysis DM’s have been treated as per NDM’s • Average annual saving 10.8% • Majority of savings as a result of WAR being higher than default load factor (not lower unit rate)

  5. Examples Disaggregation would actually lead to cheaper charges than currently. The MPAQ being significantly higher than the Peak Day SOQ which has been calculated using load factors Aggregating the Meter Points has significantly reduced the annual charge. This is due to the WAR of circa 70% leading to a much reduced Peak Day SOQ. The same reduced charge would be attainable if regular (monthly) reads were submitted.