Performance Studies & Production of the LHCb Silicon Tracker

-. GFK. CFK. Production:. Electrical Tests: internal calibration pulses reliable to detect common defects ( broken, short, pinhole ) in final modules simulated defects (artificial bonds) show similar behaviour than real ones. peakheight remainder. broken bond.

wren
Télécharger la présentation

Performance Studies & Production of the LHCb Silicon Tracker

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. - GFK CFK Production: • Electrical Tests: • internal calibration pulses reliable to detect common defects (broken, short, pinhole) in final modules • simulated defects (artificial bonds) show similar behaviour than real ones peakheight remainder broken bond short 3σ • high leakage (irradiation) affects dc-coupled readout • easy test for pinholes (bias voltage @ -0.5V & 0V) -0.5 Volts No bias voltage Stefan Koestner (University Zurich) on behalf of the Silicon Tracker Collaboration The LHCb Silicon Tracker: • TT- modules: • modules are connected to 14 sensor long ladders (4-3-3-4 and 4-2-1-1-2-4) • To reduce material inside sensitive area readout hybrids are located at the edges of detector boxes • inner sensors connected via Kapton interconnect cable (up to 55cm long) • supported by carbon/glass fibre rail • high load capacitance: 3 sensor + flex  55 pF • inter-strip capacitance 0.17 pF/cm • The LHCb experiment: • Single-arm forward spectrometer dedicated to B-physics • acceptance: 15-300(250)mrad • pp@14 TeV, luminosity=2·1032 cm-2s-1 • 1012 bb/year, full B spectrum Performance Studies & Productionof the LHCb Silicon Tracker - • The Silicon Tracker: • consists of the Trigger Tracker (TT) in front of the magnet and the Inner Tracker (IT) behind the magnet. • spatial resolution requirements ~60µm  pitch ~200µm • IT - modules: • p-n silicon micro-strip sensors (Hamamatsu) • 384 AC coupled readout strips, 108 mm long • 197µm pitch, w/p=0.25, 320(410) µm thickness • readout hybrid with 3 Beetle chips • cooling “balcony” for mounting and positioning of the ladder on the supporting cooling rod which is connected to the liquid cooling system • Carbon Fibre (CF) support produced out of high thermal conductive fibre used to cool the sensors and the detector box • Sensors • Kapton • Carbon Fibre • AIREX faom • Carbon Fibre • TT-station: • Measures transverse momentum of large impact parameter tracks in L1 • active area: 8.2m2, readout channels: ~180k, cooled to ~5°C • modules: 1,2,3-sensor-sectors (11cm, 22cm,33cm ) • 4 layers in 2 half stations, 2 layers with ±5º stereo angle • The Inner Tracker: • Provides granularity in the high multiplicity region around the beam pipe - 1.3% of sensitive area  20% of tracks • active area: 4.3m2, readout channels: ~130k • modules: 1, 2sensor-ladders (11 and 22cm) • 3 stations with 4 boxes, 4 layers per box (2 stereo):  336modules Performance: Radiation Damage (TT): • 1.6·1015 primary pp-collisions (after 10 years) • average flux up to ~4·1013 1MeV neutron equivalent/cm2 • for 1 sensor sector - (safety factor 2) minimize R/O channels & radiation length:  large pitch O(200mm)(charge collection)  long strips 33cm (noise)  “thin” sensors (little charge) 40MHz, fast readout  (noise) • Testbeam Results: • 120 GeV pions  ~MIP (minimum ionizing particle) • 3 sensor ladders with CMS, GLAST, LHCb sensors (~30cm) • 2, 1 sensor ladders with LHCb multigeometry sensors • S/N interpolation of on-strip data: • ENC = 542 + 49.83·Ctot • total capacitance linear with w/p (independent of thickness) • parameterization for 320 µm thick sensor S/N • Leakage current: • I = α·Φ·V @ 20°C • ENC2=11.56·τ·I • Pulse-Shaping • fast readout in O(charge collection time) • variable shaper feedback setting in Beetle (Vfs)  adapt to different detector capacitances • S/N interpolation of inter-strip data: • charge loss in inter-strip region (trapped on surface) • linear as a function of (pitch-width)/thickness (in the range of interest) • dominates for pitch wider than ~200 µm • Other losses in S/N (pessimistic scenario): • charge traps • increase of total capacitance S/N signal remainder 25ns after peak  specification: remainder < 0.5 (TT) < 0.3 (IT) • Module Production: • Readout hybrid and sensors are glued using custom made positioning jigs • parallel module production in several jigs Radiation Damage (IT): • up to 1·1013 1MeV neutrons/cm2 close to beam pipe • Burn-in and Final Readout Test: • temperature cycling and readout for module testing • IV measurements, Test-pulses, etc • Expected depletion voltage according to the “Hamburg Model”: • 410µm thick sensors • bulk resistivity 4-9 kΩ/cm Signal • Low material budget for cooling inside sensitive area: • liquid (C6F14) cooling for hybrids and module support • natural convection on sensor surface to prevent thermal runaway (~5 Wm-2K-1) Production tested on 4 IT and 7 TT modules so far, almost ready for full production ! Noise

More Related