过氧化氢含量的测定

过氧化氢含量的测定. 一、 主要试剂 二、 实验步骤 三、 结果表示 四、 有关常数 五、注意事项. 一、 主要试剂. 1. 0.02 mol·L -1 KMnO 4 溶液:称取 0.9 g KMnO 4 于 100 mL 烧杯中,加入大约 50 mL H 2 O ,搅拌使其溶解。静置几分钟后,将上层清液转入棕色试剂瓶中。如此重复几次,直至 KMnO 4 固体完全溶解 ( 若仍有不溶残渣,可弃去 ) ,共配成 300 mL 溶液。充分摇匀。 2. H 2 O 2 样品溶液:量取 10.00 mL H 2 O 2 样品于 250 mL 容量瓶中,用水定容。.

xaria
Télécharger la présentation

过氧化氢含量的测定

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 过氧化氢含量的测定

  2. 一、主要试剂 • 二、实验步骤 • 三、结果表示 • 四、有关常数 • 五、注意事项

  3. 一、主要试剂 • 1. 0.02 mol·L-1 KMnO4溶液:称取0.9 g KMnO4于100 mL 烧杯中,加入大约50 mL H2O,搅拌使其溶解。静置几分钟后,将上层清液转入棕色试剂瓶中。如此重复几次,直至KMnO4固体完全溶解 (若仍有不溶残渣,可弃去),共配成300 mL溶液。充分摇匀。 • 2. H2O2样品溶液:量取10.00 mL H2O2样品于250 mL容量瓶中,用水定容。

  4. 二、实验步骤 • 1. KMnO4溶液的标定:减量法准确称取Na2C2O4 0.15~0.20 g 于锥形瓶中,用 20~30 mL H2O溶解,加入20 mL (1+5) H2SO4,电炉上加热至75~85℃,用KMnO4滴定至微红色30秒不褪即为终点。(平行三份) • 2. H2O2含量的测定:取样品溶液25.00 mL于锥形瓶中,加入20~30 mL H2O、20~25 mL (1+5) H2SO4,用KMnO4滴定至微红色30秒不褪即为终点。(平行三份)

  5. 三、结果表示 以H2O2含量(g ·L-1)表示,保留四位有效数字。 计算公式:

  6. 四、有关常数 = 134.00 g·mol-1 = 34.015 g·mol-1

  7. 五、注意事项 • 1. KMnO4溶液的配制:将KMnO4溶解完全,溶液摇匀。 • 2. 标定反应条件: (1) 温度:加热至75~85℃,不能煮开,否则 C2O42-会分解。 (2) 酸度:必须控制一定的酸度。 (3) 速度:滴定速度要慢。 • 3. KMnO4溶液颜色很深,滴定管读数读液面上沿。 • 4. 溶液中的微红色30秒不褪即为终点。