1 / 10

IHE Cardiology Implantable Cardiac Device Interrogation (ICDI) Profile

IHE Cardiology Implantable Cardiac Device Interrogation (ICDI) Profile. Nicholas Steblay 2/3/2006. ICDI Profile – Abstract.

york
Télécharger la présentation

IHE Cardiology Implantable Cardiac Device Interrogation (ICDI) Profile

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. IHE CardiologyImplantable Cardiac Device Interrogation (ICDI) Profile Nicholas Steblay 2/3/2006

  2. ICDI Profile – Abstract • Cardiac electro-physiologists follow patients with implantable cardiac devices from multiple vendors. As part of patient follow-up an interrogation of a cardiac device is performed (either in-clinic or remotely from a patient’s residence). Information is collected about the device such as device identification, therapy settings, device diagnostics, and device testing. These interrogations are performed by vendor proprietary equipment. • To improve workflow efficiencies Cardiology and Electro-physiology practices require the management of “key” summary implantable rhythm control device interrogation information from a central system such as an EHR or a device clinic management system. • To address this requirement, the Implantable Cardiac Device Integration (ICDI) Profile defines a standard based translation and transfer of summary device interrogation information from the interrogation system to the information management system. IHE Cardiology

  3. ICDI Profile – In Scope / Out of Scope • Scheduling is not within scope of the profile for year one. Transactions related to placing, querying, and filling orders have been omitted. These will be incorporated in future versions of this profile. IHE Cardiology

  4. ICDI Profile – Recommended Phased Approach • Year I (2007) • Current Scope • Year II (2008) • Scheduling / Orders • Waveforms (Standards work required) • Year III (2009) • CDA IHE Cardiology

  5. ICDI Profile – Status of Standards Development • HL7 Implantable Device Domain – Cardiac Device • Negative ballots reviewed during HL7 meeting in Phoenix • Negatives deemed Non-Persuasive or Non-Substantive • Reconciliations in process • Normative in next ballot cycle • IEEE 1073 ICD Terms • Met with IEEE committee during HL7 meeting in Phoenix • Have agreed upon, peer reviewed set of terms • Clean up and structuring of content needed, final peer review, target completion date is March • April – form Ballot Group and submit ballot for vote – 45 day process • Subsequent ballot cycles are only 2 weeks • Anticipate normative terms by July IHE Cardiology

  6. ICDI Profile – ActorDiagram IHE Cardiology

  7. ICDI Profile Actors • Observation Creator • A system that creates and transmits diagnostic or therapeutic observational data. • HL7 Message Router • A system that receives HL7 messages, routes them to one or more configured actors, and handles transport level acknowledgements. • Observation Processor • A system that receives clinical observations and further processes them for inclusion within derivative products, such as clinical reports, databases, or trans-coded / reformatted results • Observation Repository • A system that receives clinical observations and stores them for subsequent retrieval and display. IHE Cardiology

  8. ICDI Profile – Actor Groupings • Observation Creator / ATNA - Secure Node • HL7 Message Router / ATNA - Secure Node • This grouping defines the approach that is required to secure transactions during a remote interrogation that transfers information across an unsecured network. • Observation Processor / PDQ - Patient Demographics Consumer • This grouping defines the approach that is required to cross reference patient identifiers. IHE Cardiology

  9. ICDI Profile – Transactions • CARD-14 Send Observation • The CARD-14 transaction is an unsolicited HL7 V2.5 ORU message containing discrete data elements and PDF document attachments associated with the device interrogation. • Standards: • HL7 Therapeutic Device Domain : Implantable Cardiac Device Topic • IEEE 1073 Implantable Cardiac Device Terms • In lieu of HL7 v3 adoption a HL7 v2.x conformance specification will be included as part of profile • HL7 v3 message may be encapsulated within OBX of HL7 v2.x message pending public comment cycle • Standard network protocols: TCP/IP, HTTPS, FTP, etc. IHE Cardiology

  10. ICDI Profile – SequenceDiagram IHE Cardiology