Linac4 BPMs: issues after 3MeV tests

Linac4 BPMs: issues after 3MeV tests. Beam observables: p osition H&V, intensity, phase variation, TOF, energy Contents: Results and issues already solved Issues in progress MD list for open issues. CERN, Beam Coordination Committee. BPMs for Linac4: issues. 27 june 2013

zion
Télécharger la présentation

Linac4 BPMs: issues after 3MeV tests

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Linac4 BPMs: issues after 3MeV tests • Beam observables: • position H&V, intensity, phase variation, TOF, energy • Contents: • Results and issues already solved • Issues in progress • MD list for open issues CERN, Beam Coordination Committee. BPMs for Linac4: issues. 27 june 2013 Michael Ludwig for the BPML4 team slide1

  2. Results and Issues already solved • position precision is very good, results from SVD analysis with Linac2 beam: <10um at 50mA p+Linac2 • Run theoretical calibration with good confidence • Electronics noise bashed successfully (now: ~10uA beam): grounding improved • Measurements contributing to 3MeV understanding: • Found 2MHz oscillation of the beam, coming from the source (plasma generation frequency). • Losses on 3rd pickup: beam touching the pipe/PUelectrodes due to beam size and steering • Slit postitonmeasurement intensity<1% => out of specs • Chopping amplitude gives V position deflection: A=50%=>beam touches lower V electrode CERN, Beam Coordination Committee. BPMs for Linac4: issues. 27 june 2013 Michael Ludwig for the BPML4 team slide2

  3. Results and Issues already solved (2) • Centering beam on SEM (using spectrometer bending) reveals off-center beam: line issue • TOF configuration issue found and solved for 3rd pickup: realistic results with ~1% variation. TOF looks good, encouraging. • FEC Software stable production mode, ergonomic GUIs in progress. Mathematica interface (1), MD scripting interface • (1): see https://edms.cern.ch/file/1289924/1/rdaMathApplication_v3.pdf CERN, Beam Coordination Committee. BPMs for Linac4: issues. 27 june 2013 Michael Ludwig for the BPML4 team slide3

  4. BPML4: Issues in progress • Short cables force short calibration pulses, calibration precision was ~10% shot-by-shot. Will improve with longer cables and calibration precision-averaging • Attenuator settings for the BPMs: not tested yet with beam • Timing jitter phase between RF gun start and ADC start sampling is not fully stable. Similar symptom observed with BCT. No show stopper, but should be understood & fixed for serious TOF. • Don’t fully understand transfer impedance Zt : simulation and measurement disagree by ~x2 • Zt depends on dp/p and on the beam size for beta <<1: need to quantify relatively • Electronics saturation above 2.5Vpp CERN, Beam Coordination Committee. BPMs for Linac4: issues. 27 june 2013 Michael Ludwig for the BPML4 team slide4

  5. BPML4: MD lists for open issues • We need to do: • Classical steering exercise with beam: fine scanning • Some energy scanning to qualify TOF fully: error estimates • Some intensity scanning (source?) to detect normalization errors and quantify them • Better definition of beam “head” and “tail” from OP: ROI settings just estimated until now, but can do much better. • We need a dipole at entry of test bench & pencil beam • Should do a full optics scan: “permutations of quads, dipoles”, record all currents and BCT, BPM. Need just 3 shots per setting, should be powerful, should confirm optics model, get ready for ABS later. CERN, Beam Coordination Committee. BPMs for Linac4: issues. 27 june 2013 Michael Ludwig for the BPML4 team slide5

  6. BPML4: Proposals &Conclusions • Proposals & Conclusions • Should have one full crate with 8 BPMs installed soon: had no chance until now. We’ll split some signals and get close to this in L4. • BPM crates must be inside faraday cage (OK with 352.2MHz): interventions, final setup, grounding • we didn’t have enough beam time for the BPM system in the 3MeV test stand: very little systematic data taking • BPML4 progressed a lot nevertheless CERN, Beam Coordination Committee. BPMs for Linac4: issues. 27 june 2013 Michael Ludwig for the BPML4 team slide6