1 / 21

Virus discovery-454 sequencing

Virus discovery-454 sequencing. Michel de Vries. Laboratory of Experimental Virology. Introduction. In 5-40 % of hospitalized patients with suspected respiratory viral infection no agent is identified. Possible problem: New or unusual subtype.

zubeda
Télécharger la présentation

Virus discovery-454 sequencing

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Virus discovery-454 sequencing Michel de Vries Laboratory of Experimental Virology

  2. Introduction • In 5-40 % of hospitalized patients with suspected respiratory viral infection no agent is identified. • Possible problem: • New or unusual subtype. • Virus Discovery cDNA-AFLP (VIDISCA) was developed in 2004. * • VIDISCA can amplify both RNA and DNA viruses without prior knowledge of the target • sequence. • Based on restriction enzyme cleavage sites + ligation of adaptors + PCR. * van der Hoek et al, Nature medicine 2004

  3. Selective PCR (16 primer combin.) Fragment separation and isolation Cloning in TA vector Colony-PCR Sequencing of colony-PCR products VIDISCA

  4. Problems • VIDISCA amplifies background ribosomal RNA (rRNA) and chromosomal DNA together with viral sequences. • This background amplification interferes with VIDISCA by acting as competitors. • VIDISCA can only amplify high viral load samples and/or low background samples. • Clinical samples such as nose washing are full with background rRNA and chromosomal DNA.

  5. Clinical samples • 12 clinical samples (nose washings) supplied by clinical virology. • Virus in the samples were identified via multiplex PCR but given double blind. • Samples containing high/medium/low viral load of known viruses. • For 1 out of 12 samples a viral sequences was obtained (HCoV-229E). • In most samples only background rRNA and DNA was identified

  6. Solution If a high number of fragments are randomly sequenced, a minority population can be identified.

  7. Primer A MID DNA fragment Primer B Next Generation Sequencing • One of NGS is the 454 sequencer of Roche, which is present in the AMC. • Per run a maximum of 1.5 E6 beads can be used resulting in about 400.000 quality sequences. • Multiplex identifiers (MID) are 10 nucleotides long barcodes that are recognized by our software. • The MID can be incorporated into samples allowing multiple samples to be pooled.

  8. Selective PCR (16 primer combin.) Fragment separation and isolation Cloning in TA vector Colony-PCR Sequencing of colony-PCR products VIDISCA- 454 454 sequencing

  9. VIDISCA-454 • Can we sequence viruses with VIDISCA-454 ? • Can we use 12 MIDs in one run ?

  10. Test with human coxsackievirus B4 • 12 times coxsackievirus B4 supernatant (2.0 E8 copies/ml) as input. • Each with a specific MID-primer A anchor. • Sequences were separated per MID, aligned and compared to GenBank database.

  11. Result

  12. Result 2

  13. Conclusion • VIDSICA-454 works!! • 12 MIDs can be used, so 12 samples can be pooled in a sequence run.

  14. Conclusion • VIDSICA-454 works!! • 12 MIDs can be used, so 12 samples can be pooled in a sequence run Are we ready for clinical samples??

  15. Result 3 • Again the12 clinical samples tested with VIDSICA-454 1 2 3 4 5 6 7 8 9 10 11 12

  16. Result 4 In 6 out of 12 samples a virus could be identified.

  17. Conclusion • With VIDISCA-454 6 out of 12 clinical samples could be identified compared to 1 out of 12 with normal VIDISCA. • An increase of sequence data by 454 sequencing results in a high chance of viral detection in clinical samples. • We are ready for clinical samples!!

  18. Advantage VIDISCA-454 • Cheaper per sample. • More samples per time unit. • More sequence information per sample. • Less interference by background amplification. • More sensitive.

  19. Problems • One of the critical steps is measuring/calculating the amount of DNA. • DNA is measured in ng/µl via fluormeter and DNA size is estimated via agarose gel. • Analyses takes 1 month. • Codoncode (aligning program) can not handle > 2000 sequences. Therefore you have to align in batches. • For analyses via Blast sequences have to be exported in batches of 100 and then submitted.

  20. Acknowledgements • Laboratory of experimental virology Nuno Faria Marta Canuti Martin Deijs Maarten F. Jebbink Lia van der Hoek • Department of Neurogenetics Marja jakobs Frank Baas • Deparment of clinical virology Richard Molenkamp • Klinische Epidemiologie, Biostatistiek en Bioinformatica Barbera van Schaik Angela Luijf micheldevries@high-throughput-sequencing.com