1 / 40

Albert Einstein College of Medicine of Yeshiva University

Goals. Knowledge of the specific and general requirements for working with radioactive materialA renewed understanding of hazards associated with the different forms of radiationThe information to choose the best instrument for detecting radiation in your labThe ability to provide a safe working environment for staff, students, and faculty.

Faraday
Télécharger la présentation

Albert Einstein College of Medicine of Yeshiva University

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


    1. Albert Einstein College of Medicine of Yeshiva University Department of Environmental Health and Safety Radiation Safety Refresher Training

    2. Goals Knowledge of the specific and general requirements for working with radioactive material A renewed understanding of hazards associated with the different forms of radiation The information to choose the best instrument for detecting radiation in your lab The ability to provide a safe working environment for staff, students, and faculty

    3. Lesson 1 Forms of Radiation

    4. Forms of Ionizing Radiation

    5. ALPHA RADIATION Consists of two protons and two neutrons (helium nucleus) Massive size, moving at 80% the speed of light Internal Hazard Particulate Radiation

    6. Examples of Beta Emitters H-3: Energy max = 19 Kev: Internal Hazard C-14: Energy max = 160 Kev: Internal Hazard S-35: Energy max = 170 Kev: Internal Hazard P-32: Energy max = 1700 Kev: Internal and external hazard

    7. Photon Radiation

    8. Examples of Gamma Emitters I-125: Energy max = 35 Kev: Internal/External Hazard Cs-137: Energy max= 662 Kev: Internal/External Hazard

    9. Bremsstrahlung Radiation Literally: breaking radiation Electromagnetic radiation produced when an electrically charged particle is slowed down by the electric field of an atomic nucleus Example: The beta particle emitted by a P-32 atom will interact with lead to give off an x-ray Bremsstrahlung production must be considered when planning the shielding of high energy beta emitters

    10. Lesson 2 Units of Radioactivity

    11. Units of Radioactivity The Curie (Ci) Commonly used in the United States 1 Ci = 3.7E10 disintegrations per second 1 Ci = 2.2E12 disintegrations per minute 1 Ci = 1000 millicurie (mCi) = 1,000,000 microcurie (uCi)

    12. RAD The RAD is the unit commonly used in the United States for Absorbed Dose (D) It is determined by the Energy that is actually deposited in matter 1 Rad = 100 ergs of deposited energy per gram of absorber Gray International Unit for Absorbed Dose 1 Gray = 100 Rads

    13. REM The REM is the unit commonly used in the United States for the Dose Equivalent Determined by Multiplying the absorbed dose (D) times a quality factor (Q) Q equals 1 for beta, gamma and x-rays, 5-20 for neutrons, and 20 for alpha Sievert International Unit for absorbed dose 1 Sievert = 100 REM

    14. It is anticipated that only beta, gamma and x-ray emitters will be used in research at Einstein The Quality factor for these forms of radiation is equal to 1 Therefore the Rad is equal to the Rem Exposure reports are documented in mREM 1 REM = 1,000 mREM

    15. Lesson 3 Half Life

    16. Half Life The half life of a materials is the time required for 1/2 of the radioactive atoms to decay The half life is a distinct value for each radioisotope

    17. Half Life of Selected Radioisotopes Flourine-18: 109.8 minutes Phosphorus-32: 14.3 days Tritium: 12.3 years Carbon-14: 5,730 years Uranium: 4,500,000,000 years

    19. Lesson 4 Background Radiation

    20. Background Radiation Natural and man-made sources of radiation everybody is exposed to in their daily lives Typically 20 to 30 mRem per month

    21. How Might I Be Exposed?

    22. Average Annual Exposure to the General Public Cosmic Terrestrial Radon Medical Total 30 mRem 40 mRem 230 mRem 90 mRem 390 mRem

    23. Lesson 5 Biological Effects & Risk

    24. Biological Effects Data is largely based on high exposures to individuals within the first half of the 20th century Biological effects occur when exposure to radiation exceeds 50 rads over a short period of time All occupational exposures are limited by city, state, or federal regulations

    25. Radiation Damage Mechanical: Direct hit to the DNA by the radiation - Damages cells by breaking the DNA bonds Chemical: Generates peroxides which can attack the DNA Damage can be repaired for small amounts of exposure

    26. Radiosensitivity Muscle Radioresistant Stomach Radiosensitive Bone Marrow Radiosensitive Human Gonads Very Radiosensitive

    27. Radiation Effects Acute Effects: Nausea, Vomiting, Reddening of Skin, Hair Loss, Blood Changes Latent Effects: Cataracts, Genetic effects, Cancer

    28. Dose Required for Acute Effects If an individual receives a dose in excess of 50 Rem (50,000 mRem) in a short period of time, he/she will experience acute effects

    29. Risk of Cancer The level of exposure is related to the risk of illness While the risk for high levels of exposure is apparent, the risk for low levels is unclear It is estimated that 1 rem TEDE of exposure increase likelihood of cancer by 1 in 1000 The likelihood of cancer in ones life time is 1 in 3 from all other factors

    30. Factors Affecting Risk The amount of time over which the dose was received The type of radiation The general health of the individual The age of the individual The area of the body exposed

    31. Lesson 6 Occupational Exposure

    32. What are the Occupational Exposure Limits ? Whole Body Extremities Skin of Whole Body Lens of Eye Thyroid 5,000 mRem/year 50,000 mRem/year 50,000 mRem/year 15,000 mRem/year 15,000 mRem/year

    33. ALARA - As Low As Reasonably Achievable. This is our policy AND the NRCs: Dont expose yourself to radiation any more than absolutely necessary.

    34. Exposure to the General Public Annual limit of 100 mRem to individuals This includes anybody in the laboratory who does not work for EINSTEIN Examples: salesmen, vendors, family members, etc.

    35. Prenatal Radiation Exposure In the embryo stage, cells are dividing very rapidly and are undifferentiated in their structure and are more sensitive to radiation exposure Especially sensitive during the first 2 to 3 months after conception This sensitivity increases the risk of cancer and retardation

    36. Declaring Pregnancy Additional dose restrictions are available for the pregnant worker Receive a monthly Luxel dosimeter Limited to 500 mRem during the term of the pregnancy Also, limited to 50 mRem per month

    37. Exposure to Minors Individuals under the age of 18 Must not receive an exposure greater than 10% of occupational exposure for adults Wholebody Exposure Limit: 500 mRem Minors will wear dosimeters in laboratories licensed for radioactive material use Minors should not work with radioactive material

    38. Lesson 7 Minimizing Exposure

    43. Internal Exposure

    44. Minimizing Internal Exposure Wear personal protective equipment If required, use a fume hood No eating, drinking or applying cosmetics Clean up spills promptly Routinely monitor work area Secure radioactive material

    45. Minimum Protective Equipment Laboratory coat Gloves Safety Glasses Dosimeters

    46. Bioassay Requirements Thyroid scan when working with volatile forms of I-125 in an amount greater than 1 mCi Urinalysis when working with tritiated water in an amount greater than 100 mCi Urinalysis when working with P-32, S-35 or Cr-51 in amounts greater than 100 mCi

    47. Lesson 8 Regulatory Requirements

    48. EINSTEINs License Broadscope license issued by The New York City Department of Health Permits the use of radioactive material in medical research Specifies limitations and requirements for using radioactive material Must be renewed every 5 years

    49. Radiation Safety Requirements Radiation Safety Officer Radiation Safety Committee Licensed Principal Investigators Radioisotope Users

    50. Records to be Kept on File ?In the Laboratory - Receipt of material - Utilization of material - Waste disposal - Monthly Wipe tests - Sink disposal - Training certificates

    51. Records (Continued)

    52. Radiation Safety Inspections Inspections are conducted quarterly Review isotope use records and wipe test records Confirm appropriate postings and labels Personal protective equipment and dosimetry Shielding and survey instrument available Contamination and radiation dose rate survey

    53. Where Will Isotopes be Found? In labs labeled with Caution Radioactive Material signs at the entrance Usually stored in freezers, refrigerators, or fume hoods Waste stored in labeled containers Radioactive waste storage rooms

    54. Postings and Labels Entrance to laboratory Refrigerator/freezer Equipment/instruments Radioactive waste containers Laboratory benches Fume hoods for use Sinks for disposal

    55. Labeling Containers All containers used for storing radioactive material or radioactive waste must be stored in labeled containers The label displays the radiation symbol with the words Caution Radioactive Material The isotope, activity in uCi or mCi and the start date should be included on label

    56. Lesson 9 Radiation Detection

    57. Detecting Radiation and Contamination Personal dosimeters are used to detect the occupational exposure to employees from external sources of radiation A survey meter may be used to detect large quantities of high energy beta and gamma emitters on a surface For smaller quantities of contamination on surfaces and low energy beta emitters, use the wipe test method

    58. Luxel Dosimeter Required when there is a possibility of receiving greater than 10% of exposure limit Monitors for gamma, x-ray and high energy beta Worn for 3 months These are individual specific - Do not loan out Return promptly after receiving a new one

    59. Ring Dosimeter Monitors exposure to the hands Used for high energy beta, gamma and x-ray radiation Worn when handling > 500 Ci of P-32 or I-125, or x-ray machines

    60. Survey Instruments Geiger Mueller (G-M) - Detects alpha, beta, and gamma radiation - Best option for detecting beta contamination Sodium Iodide Detector - Gamma and x-ray only

    61. Operational Check Check calibration date Confirm calibration date within past year Check batteries Check response to radioactive source to confirm that the meter is operational

    62. Survey Instruments Geiger-Mueller Detector Used for beta, gamma and x-ray emitters Best for P-32, S-35 and C-14 Will detect I-125 and Cr-51

    63. Wipe Test Method The Wipe Test Method is a means of monitoring for small amounts of contamination It is the only method in the lab for detecting H-3 Wipe test surveys should include both areas where contamination is expected to be found and areas where it is not expected

    64. Wipe Test Choose equipment and surfaces to wipe Use a filter paper or Q-tip to wipe approximately 100 cm2. Place filter paper or Q-tip in scintillation vial and add scintillation fluid (use enough fluid to fill at least of vial) Place sample in scintillation counter Set scintillation counter to detect radioisotopes used in laboratory Include a standard or sample containing a known amount of radioactive material Include a background or control sample

    65. Determining Activity of Wipes If the scintillation counter only provides results in counts per minute (cpm) it will be necessary to convert those results to disintegrations per minute (dpm). This can be done by including a control sample with your wipes that contains the isotope of interest.

    66. Lesson 10 Contamination Control

    67. Contamination Definition: Radioactive material in an undesired location Undesired locations: Surfaces, skin, internal, airborne Types: Removable Decontamination is possible Fixed Unable to decontaminate

    68. Contamination Limits <200 dpm/100cm2 b/g in unrestricted areas (hallways, offices, and labs not licensed for radioactive material) <1,000 dpm/100cm2 b/g in restricted areas (radioisotope laboratories) >1,000 dpm/100cm2 b/g immediately clean up to below 1,000 dpm/100cm2

    69. Frequently Contaminated Items in Laboratories Radioactive containers (stock, flasks, beakers) Laboratory benches Laboratory apparatus and equipment (Centrifuge, Freezer, Waterbath) Radioactive waste containers Refrigerator door handles Laboratory door handles Gloves and laboratory coats

    70. Contamination Control Work in areas designated for radioactive material Use absorbent pads Wear appropriate protective clothing Change gloves frequently Perform a dry run of the procedure without radioactive materials

    71. Spill Response Notify people working in the laboratory Control access to the affected area Wear gloves, lab coat, and safety glasses Clean spill from the outer perimeter inward Avoid spattering and generating aerosols After initial clean up, monitor for contamination Repeat process if contamination remains Call the RSO (x2243) if you need help or if the spill is greater than 100 Ci

    72. Decontamination of Skin If the radioactive material is a high energy beta, gamma, or x-ray emitter, monitor with a survey meter and record reading Gently wash the affected area for 15 minutes with lukewarm water and a mild soap If you continue to find contamination, repeat washing and monitoring for up to 3 times Record final survey meter readings Contact Radiation Safety at x2243

    73. Lesson 11 Obtaining Radioactive Materials

    74. Ordering Radioactive Material Orders are placed electronically through the Jacada Ordering System All orders must be approved by the Radiation Safety Officer When purchasing radioactive material from a vendor provide the following: The Radioisotope Amount of material Name and phone number of P.I. All packaged must be addressed to the Environmental Health and Safety Office in Forchheimer 800

    75. Ordering Typically, orders arrive the following day Ensure that somebody is available to pick up the Package Wear lab coat and dosimeter to pick up package Sign receipt log prior to leaving Safety

    77. Lesson 12 Radioactive Waste

    78. Radioactive Waste Disposal Minimize generation of waste Identify and segregate waste - long term (H-3 and C-14) - intermediate (S-35 and I-125) - short lived (P-32) Adhere to sink disposal limits Complete a waste ticket for pickup Keep disposal records

    79. Do Not Mix Waste Types Do not place scintillation vials into dry solid waste containers Do not place dry solid waste into liquid scintillation vial waste Do not place liquid waste container into dry solid waste containers

    80. Holding Radioactive Waste for Decay Provide appropriate shielding for the waste Seal the container to prevent individuals from adding to the waste Label the waste container with the isotope, amount of radioactive material, and date the container was sealed Hold for 10 half-lives (see table)

    81. Minimum Decay Time

    82. Discarding Decayed Waste After 10 half-lives survey the waste with a Geiger counter If no residual radiation, complete a Radioactive Waste Ticket and send white copy to Safety Place yellow copy of waste ticket on the waste to discarded Safety will pick up the decayed waste

    83. Radioactive Waste Containers DO NOT dispose of radioactive waste in: - medical waste containers - general waste containers Use only approved radioactive waste containers supplied by Radiation Safety which contains a warning label Caution Radioactive Material

    84. Scintillation Vials Place in a separate container from the dry solid radioactive waste Separate scintillation vials containing long lived isotopes (H-3 and C-14) from those containing shorter lived isotopes (P-32, I-125) Ensure the lids are secured tightly on the bottles Do not overfill the container Complete a Radioactive Waste Ticket and send to Safety when container is full

    85. Contaminated Sharps Syringes Pasteur Pipettes Scalpel Needles

    86. Collecting Liquid Use a durable plastic bottle Attach a radiation warning label to the bottle Document the isotope, activity and date on the container Secure the lid on the container at all times Place bottle in a secondary container

    87. Sink Disposal Permitted for small amount of radioactive material in aqueous solution Discard only in a radioactive materials labeled sink Disposed activity is limited to specific monthly and daily averages May need to hold short lived isotopes for decay prior to discarding down the sink

    88. Sink Disposal Limits Isotope Monthly (uCi) Daily (uCi) P-32 360 12 S-35 300 10 I-125 360 12 Cr-51 1500 50 H-3 360 12 C-14 900 30

    90. Lesson 13 Clearing Equipment

    91. Clearing Equipment For repair by Engineering or Vendor: Ensure equipment is empty of all samples, containers, and radioactive material Conduct wipe test and present results to RSO Monitor with survey meter Decontaminate equipment if required

    92. Lesson 14 Review

    93. When Working with Low Energy Beta Emitters Examples: H-3, C-14, S-35, P-33 Follow General Safety Requirements Use a GM survey meter for large quantities of C-14, S-35 and P-33 Isolate, label, and dispose of waste Secure material in refrigerator/freezer

    94. When Working with High Energy Beta Emitters (P-32) Use Plexiglas shielding for storage Wear Luxel dosimeter and extremity dosimeters if required Handle material behind a Plexiglas shield Regularly monitor work area and gloves for contamination Use a GM detector or liquid scintillation counter

    95. Working with Gamma or X-ray Emitters (I-125) Store in leaded containers Pre-experiment thyroid scan for work with large quantities or volatile forms of I-125 Wear Luxel dosimeter and extremity dosimeters if required Use leaded glass/Plexiglas shield Regularly monitor surfaces gloves Use NaI detector or liquid scintillation counter Post experiment thyroid scan for work with large quantities or volatile forms of I-125

    96. Telephone Numbers Radiation Safety: x2243 General Safety: x4150 Fax: x8740 Environmental Health & Safety website: www.aecom.yu.edu/ehs

More Related