Computer Power Management for Enterprises Mike Walker, Beacon Consultants

Computer Power Management for Enterprises Mike Walker, Beacon Consultants. A Practical Guide for Saving up to $100 per PC Annually. Outline. History: Estimated Energy Use of Computers and Monitors (1998 – 2006) ENERGY STAR: Your Solution for Minimizing Computer Electricity Use

Jimmy
Télécharger la présentation

Computer Power Management for Enterprises Mike Walker, Beacon Consultants

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Computer Power Management for EnterprisesMike Walker, Beacon Consultants A Practical Guide for Saving up to $100 per PC Annually

  2. Outline • History: Estimated Energy Use of Computers and Monitors (1998 – 2006) • ENERGY STAR: Your Solution for Minimizing Computer Electricity Use • Computer Power Management • VISTA May Make CPM Easier to Implement • How to Move Forward in Your Organization

  3. Estimated Energy Use of Computers and Monitors (1998 – 2006)

  4. Computer Wattage Now Exceeds Monitor Power

  5. …And the Stock is Large

  6. PM Utilization: High for Monitors, Low for Computers

  7. Energy Use of Monitors

  8. Energy Use of Computers

  9. What Would 50% CPM Accomplish? • Electricity to light 8 million homes • Reduce 6 million tons of CO2 • Remove 1 million cars from the road

  10. ENERGY STAR: Your Solution for Minimizing Computer Electricity Use

  11. ENERGY STAR is Your Tool for Reducing Computer Power Use zzzzzzzz…

  12. Computer Power Management

  13. What is Power Management? • Monitor power management (MPM) places active monitors into a low power sleep mode after a period of inactivity • System standby and hibernate features place the computer itself (CPU, hard drive, etc.) into a low power sleep mode

  14. What is Power Management? • Built into Windows 95,98, ME, 2000, XP and now Vista • Settings simply need to be activated

  15. Why Power Management? • Use less electricity • Half of energy used to power PCs is wasted • Reduce peak load demand charges • Some utilities charge up to $200 per kW per year, many charge $150/year • Roughly every 180 PCs or monitors power managed saves 1 kW of peak demand • Reducing cooling loads • Typical office bldg with internal heat load and moderately efficient system saves an additional 15% • In southern climates savings can be 30% or more

  16. Computer Power Management (CPM) • Flavors of CPM • Sleep(System Standby S3) • saves 40-80W • wakes up in seconds • Hard disk spin down • saves very little • Hibernate (S4) • same energy savings as S3 • wakes up in 20+ seconds • saves work in the event of power loss • Shutoff (S5) • same energy savings as S3 • wakes up in 20+ seconds • saves work in the event of power loss • Original goal of CPM: maximize laptop battery life • Increasingly deployed to save electricity on desktops (on AC power) -- can save up to $50 per computer annually • Modern CPM shuts down critical system components -- CPU, PCI bus, fans, et al; • Most PCs currently use S3/S4 for sleep, and S5 is sometimes used to save power

  17. CPM’s ROI • CPM activation in networked environments is not as straightforward as MPM • Care must be taken to ensure that sleeping computers do not interfere with the distribution of administrative software updates • Older software applications and some peripheral devices may not conform to the latest ACPI standards, and should be tested for compatibility with CPM • Still, given the savings potential, CPM offers a tremendous ROI • An org with 6000 PCs can expect to reap 3 year savings in excess of $1 million, with costs typically in the low thousands

  18. CPM: Where it works best • Pentium IV (or newer) processors • Windows 2000 or XP • Regular administrative software updates are “pulled” by clients from the network, or Wake on LAN features are available to wake up client machines to receive administrative updates • Energy savings (up to $50 per PC annually) are compelling enough that organizations are adopting CPM

  19. Various Approaches to CPM are Working

  20. Software Tools • PolicyMaker • Centrally control MPM and CPM on PCs using group policies • www.desktopstandard.com • Surveyor Network Energy Manager • Measures energy consumed by network • Manages power settings of PCs and monitors • www.verdiem.com • NightWatchmanTM • Shuts down computers and monitors when not in use • www.1e.com/SoftwareProducts/NightWatchman/Index.aspx • EZ GPO • Group policy object solution for MPM and CPM • Download for free at www.energystar.gov/powermanagement • Apple’s Mac OS X 10.4 (Tiger) Server • Centrally control MPM and CPM on Macs using built in policy manager • www.apple.com/server/macosx • Apple’s Remote Desktop 2 • Centrally control MPM and CPM on Macs • www.apple.com/pr/library/2004/jun/21ard.html

  21. VISTA May Make CPM Easier to Implement and Use

  22. Windows Vista • Microsoft is extending Windows power management features in Vista. Anticipated improvements include… • Smarter “hybrid sleep” will be the default when the power button is turned off • Vista includes tools called Group Policy Objects that IT administrators can use to easily control CPM. These did not exist in XP. EPA’s GPO tool was a way to get around this limitation. • Vista will be shipped with MPM and CPM defaulted • Software applications will no longer be allowed to veto sleep

  23. How to Move Forward in Your Organization

  24. Suggested Tasks • Review behaviors • Shut off at night • Sleep enabled for monitors and computers • Calculate savings • Energy managers • Senior staff • Contact EPA for help if needed • Engage your IT department • Central management of CPM • Need to access computers at night

  25. How to Centrally Manage CPM • Use in house solutions • 3rd party software • EPA’s EZ GPO tool activates system standby (S3/S4) • Vista supports central management of CPM related settings • Desktop Standard’s PolicyMaker (also MS) activates S3/S4 • Verdiem’s PC Surveyor manages PM features and implements time-based power profiles • 1E’s NightWatchman remotely turns off computers (S5); requires enabled WOL

  26. Access to Sleeping Computers • OBSTACLE: Many IT managers perceive need for continuous availability • SOLUTION: • Sites can wait for maintenance events (patching, backup, etc) to occur on wake up (GE does this) • Wake-on-LAN (WOL) can be implemented • Scheduled wake ups can provide needed availability

  27. Wake-on-LAN: What is it? • WOL is a means to wake networked machines • Originally designed to allow for remote administration of client PCs • NIC signals a PME to wake the machine when it receives network traffic • The NIC can be configured to look for specific types of network traffic (ie “The Magic Packet”) • Various configuration and network topology is required to make this work

  28. Technical Assistance • We help develop energy savings estimates • We help IT administrators quickly identify the easiest, lowest risk paths to power management • A brief conference call with your IT administrator(s) is usually all it takes to get started

  29. Summary • Implementing MPM and CPM can save $50 per PC annually • Many organizations are already saving • IT managers are overcoming obstacles to CPM • Growing number of large-scale implementations • We can help you develop your implementation options

  30. Contact Information • Additional information at: www.energystar.gov/powermanagement • Contacts: • Mike Walker, Beacon Consultants (EPA Technical Support Contractor): 617-921-8445, mwalker@beaconconsultants.com • Steve Ryan, US EPA Energy Star Program Manager: 202-564-1254, Ryan.Steven@epamail.epa.gov