1 / 3

Clinical-centrifuge-LB-32LCC

<br>Introducing Clinical Centrifuge: the pinnacle of lab efficiency. <br>Designed for precision, it swiftly separates samples with ease. <br>User-friendly interface, compact formu2014refine your clinical <br>workflows with this centrifuge.

Mary238
Télécharger la présentation

Clinical-centrifuge-LB-32LCC

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Clinical centrifuge LB- 32LCC info@labotronics.com www.labotronics.com

  2. Overview Clinical centrifuge is an automated low speed centrifuge with speed range of 300 rpm ~ 4500 rpm to achieve accurate and excellent performance. Dynamic balancing mechanism ensures stability during cycles. Run-time can be adjusted between 30 s to 99 mins or continuous running. Automated door interlock design signals on completion inhibiting overheating of samples. Specifications : Speed range 300 rpm ~ 4500 rpm Maximum RCF 2490 ×g Speed accuracy ± 20 rpm Time range 30 s ~ 99 mins / Continuous operation Speed increment 100 rpm Maximum RCF increment 100 ×g Power (single phase) AC 110 V ~ 240 V, 50 Hz/60 Hz, 3A Acceleration / Braking time 20s↑20s↓ Dimensions 225 x 245 x 140 mm Weight 10.8 kg Features : Plastic rotor- High strength, flame-retardant, impact resistant, chemical resistant LED display – to view running process, error warning Control knobs –adjusting speed and time

  3. Run parameters can be adjusted after the set speed is reached Self-diagnostic check: indicates accumulative running time and last running parameters PULSE key- short spin function Applications : Used for separation of platelet rich plasma, urea, serum and in hospitals for routine tests, also in research institutes. Rotor Selections : Rotor type Max. RCF Capacity ( ml ) 10 × 12 tubes Angle rotor 2490 ×g 7 × 12 tubes 5 × 12 tubes 15 × 8 tubes Labotronics Ltd. Union House, 111 New Union Street, Coventry CV1 2NT, UK info@labotronics.com| www.labotronics.com

More Related