1 / 16

An NLTL based Integrated Circuit for a 70-200 GHz VNA System

An NLTL based Integrated Circuit for a 70-200 GHz VNA System. O. Wohlgemuth, B.Agarwal*, R. Pullela*, D. Mensa*, Q. Lee*, J. Guthrie*, M. J. W. Rodwell*, R. Reuter, J. Braunstein, M. Schlechtweg, T. Krems, K. Köhler

Melvin
Télécharger la présentation

An NLTL based Integrated Circuit for a 70-200 GHz VNA System

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. An NLTL based Integrated Circuit for a 70-200 GHz VNA System O. Wohlgemuth, B.Agarwal*, R. Pullela*, D. Mensa*, Q. Lee*, J. Guthrie*, M. J. W. Rodwell*, R. Reuter, J. Braunstein, M. Schlechtweg, T. Krems, K. Köhler Fraunhofer Institute for Applied Solid State Physics (IAF),Tullastr. 72, D-79108 Freiburg - Germany *Department of Electrical and Computer Engineering, University of California, Santa Barbara, CA 93106 Archivierungsangabe

  2. Outline • Motivation • Conventional S-parameter measurement set-up and integration on a chip • Design and fabrication • Performance of the • integrated components • full chip • Summary Archivierungsangabe

  3. Advancement in III-V technology especially in InP based devices HEMTs and HBTs with fmax > 500 GHz ICs, operating above 120 GHz Presently no commercial broadband on-wafer S-parameter measurement system above 120 GHz available Motivation Archivierungsangabe

  4. Measurement System Archivierungsangabe

  5. Block Diagram of the Chip Archivierungsangabe

  6. NLTL • Limiting faktors: • Bragg Frequency • Skin-effect loss and diode loss MD, 26th EuMC 1996

  7. Technology • Planar Schottky diode process • N- layer exponential doped • Further process steps: • Interconnect metal, • Si3N4 • Air bridges MD, 26th EuMC 1996

  8. Problems with High Drive Frequency • High skin-effect losses • DC walk of because of the high loss • Doides are driven through a minor capacitance variation • Only low power available • Long lines neccassary, to reach enough compression MD, 26th EuMC 1996

  9. Design of the Multiplier NLTL • Bragg frequency increases exponential • Air bridge line combines wide center conductor with high Bragg frequency Line length: 4.2 mm MD, 26th EuMC 1996

  10. Waveform at the Output of the Multiplier NLTL • Input: • 36 GHz sine wave with 12 dBm power • Measured output: • ~4.1 ps fall time Archivierungsangabe

  11. Coupler designed for 10 dB coupling Zeven, Zodd, geven and godd are calculated with a 3D simulator (HFSS) Measured directivity of the coupler using on-wafer sampling circuits Directional Coupler Designed for 180 GHz MD, 26th EuMC 1996

  12. Low Pass Filter Low pass filter neccassary with low reflection over the entire bandwidth ZL=75W C choosen for Zeff=50W MD, 26th EuMC 1996

  13. Nonlinearity of the Sampling Circuits • Sampling circuit was driven with a input frequency of 36 GHz • Harmonic generation is negligible for input powers below 0 dBm MD, 26th EuMC 1996

  14. Not in the simulation included are: Attenuation of the sampling circuit Skin-effect losses of the coupler -35 dBm @ 200 GHz is sufficient for measuring Power at the DUT Archivierungsangabe

  15. Measurement of 2 Chips 50 W (44 +/-1.5 W) chip resistor open test port Measured Directivity of the Full Chip MD, 26th EuMC 1996

  16. Summary • The first IC, which can be used as a S-parameter test set within 70-200 GHz • Design and fabrication • Performance of the single components and the full chip • Packaging these chips into active probes will permit convenient on-wafer S-parameter measurements This work was supported by the German Ministry BMBF in the frame work of 01BM620 (555339) Archivierungsangabe

More Related