Ambient Air Monitoring for the Revised Lead NAAQS Daniel Garver US EPA Region 4
Overview • On October 15, 2008, EPA strengthened the national ambient air quality standards (NAAQS) for lead (Pb). • Since 1978, lead standards have been set at 1.5 μg/m3 • Now,EPA is strengthening the lead standards by 90 percent to a level of 0.15 μg/m3. • The level is based on the concentration of lead in total suspended particles (TSP) • EPA is also making changes to the lead monitoring network to ensure monitors are assessing air quality in areas that might violate the new standard.
NAAQS Averaging Time and Form: Old vs. New NAAQS • Both specified as “not be exceeded” maximum 3-month average • Both require 1 in 6 day sampling frequency • Old NAAQS based on calendar quarters; new NAAQS based on “rolling” 3-month averages • Also, the 3-month averages (for Old versus New) are calculated slightly different • Data handling details in 40 CFR 50 Appendix R • NAAQS evaluation period handled differently • Old NAAQS had 1-year “look” for designations and 2-year evaluation period for redesignations • New NAAQS will use 3-year look for original designations and also redesignations
Lead Monitoring Requirements • Lead monitoring required: • At sources emitting 1.0 tpy or more of Pb based on NEI or other justifiable data. • In core-based statistical areas (CBSAs) with population over 500,000. • Approx. 48 total required monitors in Region 4 • Approx. 22 source-oriented monitors must be identified in Network Plans and installed by 1/1/2010 • Monitors must be sited for max concentration, taking into account logistics and the potential for population exposure.
Source-Oriented Monitoring Waivers[40 C.F.R 58 Appendix D 4.5(a)(ii)] • EPA can grant waivers of required source-oriented monitors if State or Local can demonstrate that: • Maximum Pb concentration will not exceed of 50% of the NAAQS (based on historical monitoring data, modeling, or other means). • Modeling info at EPA’s Support Center for Regulatory Atmospheric Modeling (SCRAM) website at epa.gov/scram001 • AERMOD is the preferred model for near-field dispersion • EPA is creating a post-processing program that reads model output and calculates rolling 3-month averages. • Model must demonstrate max concentration < 0.075μg/m3 • Ambient air means outside facility fence line provided that all of facility property is secured from public access
Source-Oriented Monitoring Waivers (cont.)[40 C.F.R 58 Appendix D 4.5(a)(ii)] • Waiver request letters must be submitted with Network Plans due July 1st. • All required sources must have either: • Signed monitoring waiver, or • Pb monitor operating by January 1, 2010.
Ambient Monitoring Methods • Primary indicator is lead in total suspended particles (Pb-TSP), due to evidence that lead particles of all sizes pose health risks. • Pb-PM10 can be used instead of Pb-TSP monitoring if: • Lead is not expected to occur as large particles; and • Lead concentrations are not expected to have three-month averages greater than or equal to 0.1 μg/m3 • If a Pb-PM10 monitor measures to 0.1 μg/m3 or above, then Pb-TSP monitor must be installed within six months • Pb- PM10 measurements greater than the NAAQS violate the standard. • Anticipate that Pb-PM10 can be used at most or all of the population-oriented sites. • Note that Pb-PM10 data is considered surrogate data for Pb-TSP, and cannot be used to demonstrate attainment with the NAAQS.
Pb-TSP Sampling • High-volume TSP (total suspended particulate matter) sampling • 40 CFR Part 50, Appendix B • Federal reference method (FRM) approved in 1983 for collecting TSP • Collects particles up to 25-50 μm • Flow rate of 1600 liters per minute (LPM) resulting in total 24-hour sample volume of ~2400 cubic meters • Typically samples on 8x10-inch glass fiber or quartz filters
Sampling Methods: Pb-PM10 • Low-volume PM10 sampling • Analysis: 40 CFR Part 50, Appendix Q • PM10c Sampler FRM: 40 CFR Part 50, Appendix O • Collects particles less than or equal to 10 micrometers • Low-volume sampling at flow rates of 16.7 LPM resulting in total 24-hour sample volume of ~24 m3 • Any approved FRM/FEM PM10c sampler can be used when coupled with the FRM Pb-PM10 analysis.
Additional Resources • Lead monitoring information and NAAQS Q&A documents: http://www.epa.gov/ttn/amtic/pb-monitoring.html • Regulatory actions related to the Lead NAAQS including text of the final rule: http://epa.gov/air/lead/actions.html • 2005 National Emissions Inventory (NEI) data for lead sources: ftp://ftp.epa.gov/EmisInventory/2005_nei/lead_summaries/