Technical Support – Standards & Programs R. Lee Lippincott Ph.D. Research Scientist 1 A-280 Research Project Manager

Technical Support – Standards & Programs R. Lee Lippincott Ph.D. Research Scientist 1 A-280 Research Project Manager Bureau of Environmental Assessment Chair, NJAWWA Research and Technology Transfer Committee. Analytical Program Support Water Quality Standards.

adamdaniel
Télécharger la présentation

Technical Support – Standards & Programs R. Lee Lippincott Ph.D. Research Scientist 1 A-280 Research Project Manager

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Technical Support – Standards & Programs R. Lee Lippincott Ph.D. Research Scientist 1 A-280 Research Project Manager Bureau of Environmental Assessment Chair, NJAWWA Research and Technology Transfer Committee

  2. Analytical Program SupportWater Quality Standards • Surface Water Quality Standards • N.J.A.C. 7:9B • Ground Water Quality Standards • N.J.A.C. 7:9-6 • New Jersey Safe Drinking Water Act (A-280) • P.L. 1983, c.443 • NJMCLs • N.J.A.C. 7:10-16

  3. Technical Support:Standards Development • NJDEP: Bureau of Ground Water Pollution Abatement • NJDEP: Bureau of Safe Drinking Water • NJDEP: Division of Water Quality Planning and Standards

  4. Technical Support Request

  5. PQL Objectives • To Quantify Chemical Contaminants at the Human or Aquatic Criterion Levels • To Determine Laboratory Capability • Theoretical • Current New Jersey Certified

  6. Method Performance SourcesTheoretical Laboratory Data • EPA • ORD Methods (500 series) • EAD Methods (1600 series) • SW846 Methods • APHA Standard Methods • USGS Scheduled Methods • Literature Research Methods

  7. Internet ResourcesTheoretical Precision and Accuracy Data • EPA • (100-900 series) • (1600 series) • USGS Scheduled Methods • ASTM Methods • http://infotrek.er.usgs.gov/servlet/page?_pageid=202,204,1160&_dad=portal30&_schema=PORTAL30

  8. Internet ResourcesTheoretical Precision and Accuracy Data • SW846 Methods • http://www.epa.gov/epaoswer/hazwaste/test/3_series.htm

  9. Method Performance SourcesTheoretical Laboratory Data • APHA Standard Methods • CDROM Methods • Literature Research Methods • Dialogue Search by NJDEP Information Resource Center (IRC)

  10. Method Performance SourcesTheoretical Laboratory Data • Determine a consistent Method Detection Limit (MDL) using published methods • Apply a multiplier to determine theoretical PQL • Multiplier range (3 to 5 times MDL)

  11. PQL Overall DesignCurrent New Jersey Certified Laboratory Data • New Jersey is a NELAP Recognized Accrediting Authority • NJ Certified Laboratories will submit method performance data as part of an annual demonstration • Office of Quality Assurance will maintain a database of this information

  12. Method Performance SourcesCurrent New Jersey Certified Laboratory Data • NJDHSS Laboratory • State Primacy Lab • Site Remediation “Equis” Database • BSDW Compliance Database • Private Well Testing Act Database

  13. Detection Limit Issues • Many regulatory standards near detection limit • Lab credibility often associated with detection limits • Maze of tests and matrices make it difficult to find a universally applicable technique • Calculating detection limits can be expensive

  14. Two Main Approaches to Calculating Detection Limit • Single Point • based on variability of analyte response at a single concentration • Multiple Point • Calibration Design

  15. Single Point Approach to Calculating Detection Limit • Method • 40CFR Part 136 Appendix B • Seven (7) replicates at ~ [5 times] the background noise • Multiply by (z) distribution factor • 3.14 time the S.D. = MDL

  16. Multiple Point Approach to Calculating Detection Limit • Calculate the detection limit from variability in analyte response from a series of standards spiked over a range of concentrations

  17. Multiple Point ApproachLinear Least Squares Regression YD Instrument Response YC 0 LC LD Concentration

  18. Multiple Point Approach Weighted Least Squares Regression Instrument Response YC LC LD

  19. Summary • Outlined program structure • Defined Inputs and Outputs for Technical Support • Presented the methodology for determining parameter specific Standards

  20. How Results Can Be Used ? • By DEP • To understand evolving improvements in Analytical Methods • To monitor sensitivity improvements to eventually quantify chemicals at the criteria level • To have a central source of information that defines the Data Quality Objectives for programs