1 / 13

GS3055-I Installation Process

GS3055-I Installation Process. GS3055-I Overview. The GS3055-I is : A universal wireless alarm communicator that can be used as a backup or primary communicator

alia
Télécharger la présentation

GS3055-I Installation Process

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. GS3055-I InstallationProcess

  2. GS3055-I Overview • The GS3055-I is: • A universal wireless alarm communicator that can be used as a backup or primary communicator • A device which connects the alarm control panel to the GSM network and reports alarm signals directly to a monitoring central station receiver (Sur-Gard System III with a DRL3-IP line card or System II) • A digital transmitter which provides full reporting from any control panel that communicates using Contact ID format

  3. GS3055-I Service Provider • Who is CONNECT 24? • CONNECT 24 is the GS3055-I service provider • CONNECT 24 provides the automated telephone activation system for the activation of GS3055-I units (GVRU, Voice Response Unit) • CONNECT 24 provides the web-user interface support for the programming of GS3055-I units(future use) • CONNECT 24 provides account administration, billing and rate plans to GS3055-I customers

  4. GS3055-I Enrolment Steps In order to properly enrol a GS3055-I unit you must follow these steps: Important Note: Prior to installing a GS3055-I you must first become an authorized dealer. Please consult your central monitoring station for master reseller programs or visit www.connect24.comand complete the authorization form STEP 1 – Activate your SIM card with Connect 24* STEP 2 – Initialize the GS3055-I with Connect 24* STEP 3 – Determine best signal strength location STEP 4 - Connect the GS3055-I to the control panel STEP 5 - Program the control panel to use the GS3055-I STEP 6 – Test the GS3055-I * Note: GS3055-I unit must be powered down for STEPS 1 and 2

  5. GS3055-I SIM Card Activation (GVRU) • Prior to installation, each SIM Card must be activated via the Connect 24 GVRU (1-866-910-3865, option [6]). Activations must be performed at least 24 hours before to installation (initialization) • The following information is required when activating a SIM Card: • Installer’s ID Number: Identifies each installer listed on the Dealer Enrolment Form • Installer’s PIN Number: Identifies each installer with a 4 digit PIN number • The SIM Card Number:(Subscriber Identity Module), 19-20 digits located on SIM Card Note:Only authorized dealers can activate a SIM Card with CONNECT 24

  6. GS3055-I Initialization (GVRU) • GS3055-I initializations can be performed via the Connect 24 GVRU (1-866-910-3865, option [4]) • Enter the following information and options when initializing a unit: • Profile Number: Represents the Central Station Receiver IP address and Rate Plan • Installer’s ID Number: Identifies the installer listed on the Dealer Enrolment Form • Installer’s PIN Number: Identifies the installer • The Central Station Account Number: Represents the account number that will be transmitted to the Central Station Receiver • The SIM Card Number: (Subscriber Identity Module), 19-20 digits located on SIM Card • The DNIS Number: (Dialled Number Information Service), Check with your Central Station • 7. Test transmission selection: select the required test schedule (no test, daily, weekly or monthly) • Determine if GS3055-I unit is the primary or backup communicator: enable/disable TLM (telephone line monitor) option Note:Only authorized dealers can activate a SIM Card with CONNECT 24

  7. GS3055-I Signal Strength Test • To test the signal strength of a GS3055-I: • Connect the antenna to the GS3055-I • Ensure that the SIM card is installed into the GS3055-I • Connect the battery to the GS3055-I • Signal strength levels: • LED#3 and LED#4 ON = Excellent Signal Strength • LED#4 ON = Good Strength • LED#4 Flashing = Poor Signal Strength • Both OFF = No signal Strength • Note: For proper installation, a GS3055-I must have Good or Excellent Signal Strength. If a poor strength is detected, the unit should be relocated or an antenna extension should be used LED# 3 LED #4

  8. GS3055-I – Telephone Wiring (Back-up Mode) To Power Supply From RJ-31X Demarcation To Premise Telephones

  9. GS3055-I Control Panel Programming The following control panel programming is required : • Telephone number * • Account number • Communications format – Contact ID • Reporting codes or select automatic reporting** • Communications enabled *If communicating only using the GS3055-I (no land-line), program any telephone number **If supported by the control panel

  10. GS3055-I Testing • To test the GS3055-I, perform the following: • Disconnect the telephone line from the TIP and RING terminals on the GS3055-I • Wait for LED 2 (YELLOW) to turn ON (indicates that the unit is in GSM mode) • Force the control panel to transmit a signal (i.e. zone alarm, keypad alarm etc.) • Connect a handset to RING and TIP on the control panel to verify that the control panel is communicating

  11. GS3055-I – Testing Diagram To Power Supply Connect the 12V/1.2AH Battery to the GS3055-I To Premise Telephones

  12. GS3055-I Assistance Directory Connect 24 Phone Number: 1-888-955-5583 (Canada) 1-888-251-7458 (US) Fax: 1-877-224-3676 Website: www.connect24.com E-mail: customerservice@connect24.com GVRU Activation and Initialization: 1-866-910-3865 DSC Technical Support Phone Number: 1-800-387-3630 E-mail: tech@dsc.com Website: www.dsc.com

  13. GS3055-I Questions?