Advanced Coal Conveyor Fire Protection System | Agni Controls

Agni Controls specializes in cutting-edge fire safety systems for coal conveyors. Our Infra-Red Ember Detector technology is crucial for early detection and prevention of conveyor belt fires.

amarco
Télécharger la présentation

Advanced Coal Conveyor Fire Protection System | Agni Controls

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Committed to Fire Safety * * No.1, 6th Street, Dr. Subbarayan Nagar, Kodambakkam, Chennai - 600 024. India. Ph. No. : +91 – 044 – 24812420 Fax No.: +91 – 044 – 24812475

  2. TM f'ladet series…. • IH 153E – IR Ember Detector • for • Coal Conveyor Fire Protection

  3. About Ourselves • 1985 – M/s. Agni Controls Established as Custom Built Panel Manufacturer • 1987 – Started to Manufacture Conventional Fire Alarm Panel • 1988 – Started to provide Gas Based Extinguishing System as a specialized Fire Protection Engineering Company • 1991 – Developed Special Infra Red Technology Spark Detectors for protecting Ducts • 1993 – Developed Special Probe Type Heat Detector for Paint Booths, Kitchen Hood and Battery compartments

  4. TM f'ladet About Ourselves • 2003 – Developed Water Mist System • 2003 – Developed Gas Weight Monitoring Device suitable for Gas Based Systems • 2003 – Introduced the brand Name for the Gas Based Systems & Components • 2003 – Developed Ultra-Violet & Infra Red type Flame & Ember Detectors • 2005 – Introduced the brand Name SERIES… for all Special Application Products – Flame/Ember/Spark/Heat Detectors • 2007 – Introduced Fully Integrated & Tested Cylinder Bank Assembly

  5. The Systems We Offer • CO2 Fire Extinguishing System & Components • Continuous Gas Weight Monitoring System & Components • Inert Gas Clean Agent System & Components • Fire Alarm System & Components • Intrinsically Safe Fire Protection System & Components • Diversion / Spark Detection System & Components • Special Application Detectors

  6. COAL CONVEYOR PROTECTION

  7. INTRODUCTION • * If a smoldering coal or embers are introduced due to spontaneous combustion onto a conveyor during a loading and unloading operation, it is every possibility to be conveyed to a transfer point, crusher or silo or bunker. • * At such places hot coal may ignite combustible dust accumulations and may lead to large scale Fire incident. • * Critical Equipment losses, production loss, property loss, loss of human life are need not to be elaborated. • * Coal Conveyer Fire Protection is very much essential and important.

  8. WHAT IS EMBER

  9. PROTECTING COAL CONVEYOR PROTECTING COAL CARRIED IN CONVEYOR BELT LHS CABLE FOR PROTECTING CONVEYOR BELT CONVEYOR BELT

  10. DETECTION IN COAL CONVEYOR PROTECTION

  11. TM f'ladet IH 153E – Infra Red Ember Detector

  12. BASIC CONCEPT • Infra Red Ember Detector are used to detect hot moving spots on the conveyor before they reach processing machinery or storage hoppers and initiate alarm and Fire Extinguishing arrangement. PRINCIPLE OF DETECTION Hot Carbon Dioxide and Carbon Monoxide produced by the Coal Ember is emitting Infra Red radiation. IR Sensor in the Detector responds when the Ember enters the sensor filed of view.

  13. PRODUCT INTRODUCTION • Agni Controls is pioneer in IR Technology. • Our IR Spark & Ember are widely used in Machinery Protection • especially in Textile Industries for last 18 years. • More than 5000 Nos. of IR Spark/Ember Detectors are in operation. • fladet - IH153E Infra Red Ember Detectors are specially designed to detect moving ember with 90 Deg. Cone view. • Detector is designed with four independent Infra Red Sensors and special electronic logic analysis is used to give the best result. • IH 153E IR Detector with IP 67 protection is well suitable for dusty environments.

  14. IH – 153E • fladet IH 153E IR Detector with unique features makes the detector user friendly and least maintenance requirement. • Flashing Green LED indicates healthiness of the Detector 4 wire system 2 wire for Input Supply and 2 wire suitable to connect any Standard Fire Alarm Zone / PLC/ Annunciation. • No Separate Control Panel is required. Any Annunciation or PLC or fire Alarm Panel can be used. • Air Purging provision makes cleaning very simple. By connecting existing instrument air, the Glass surface can be cleaned either by simple manual method or by automatic arrangement as per site requirement. Dedicated separate air source also can be incorporated. • IH 323 Air Purging Unit is Stand Alone Provided with Air Blower operated on 230 V AC.

  15. IH – 153E • The Detector is cost effective because of the above referred flexibility. • Simple mounting bracket with tilting arrangement is used to easy field erection and maintenance • Spectral Filter is 3000-14000 nm. • Because of the critical spectral range it is ineffective to sunlight, other lights. • Cone of Vision is 90 Deg. which makes wider coverage. • Wider Range of operating Temperature (-40Deg.C to 60 Deg. C) and Input supply voltage 24 V DC+/-20% ensure proper detection performance. • Non ferrous Rugged enclosure suitable for dusty and windy environment with IP 67 protection.

  16. TM f'ladet

  17. TM f'ladet DETECTOR POSITION

  18. DETECTOR POSITION ๏ Detector should be mounted on the conveyor hood or gantry structure looking down at the coal being transparent. ๏ Detector will detect 100 Sq. cm glowing coal ember at the distance of 3 ft. ๏ Detector cone of angle is 90 Deg. across the belt. It is recommend to mount the Detector at a height equal to half width of the conveyor. ๏ For increased sensitivity two Detectors are recommended if the width is more than 2 meters. ๏ It is recommended to a minimum of two Infrared Ember Detector for each conveyor. ๏ In normal practice close to the tail pulley one set of Detectors and close to Head pulley, another set of Detectors may be located. ๏ These detectors shall be wired as separate zone in the control panel.

  19. TM f'ladet IH – 153E • IH153E SPECTRAL RESPONSE

  20. TM f'ladet DETECTOR TYPICAL WIRING SCHEME

  21. TM f'ladet DETECTOR TYPICAL WIRING SCHEME

  22. TM f'ladet DETECTOR TYPICAL WIRING SCHEME

  23. TM f'ladet AIR PURGING ₪ Air Purging provision makes cleaning very simple. ₪ By connecting existing instrument air, the Glass surface can be cleaned either by simple manual method or by automatic arrangement as per site requirement. ₪ Dedicated separate air source also can be incorporated.

  24. TM f'ladet AIR PURGING

  25. TM f'ladet IH 323 - AIR PURGING UNIT

  26. TM f'ladet STAND ALONEIH323 AIR PURGING UNIT 4

  27. For Special Detection Solution in Hazardous and Challenging areas Please contact our Special Application Product (SAP) Division at Phone:+91-044-2481 2420 Fax: +91-044-2481 2475 Email : marketing@agnicontrols.com balachandran@agnicontrols.com Visit us at : www.balafire.com

More Related