1 / 2

Open questions & Working plan 1. C6D6 (Claudia, Cristian , Giusepe and Kevin)

Open questions & Working plan 1. C6D6 (Claudia, Cristian , Giusepe and Kevin) 1.1. Reported differences between normalization to gold at thermal and 4.9 eV (maybe related to beam interception factor AND/OR neutron flux of 2011 vs. 2010) obtain normalization from gold @ 200 keV

amena
Télécharger la présentation

Open questions & Working plan 1. C6D6 (Claudia, Cristian , Giusepe and Kevin)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Open questions & Working plan 1. C6D6 (Claudia, Cristian, Giusepeand Kevin) 1.1. Reported differences between normalization to gold at thermal and 4.9 eV (maybe related to beam interception factor AND/OR neutron flux of 2011 vs. 2010) obtain normalization from gold @ 200 keV 1.2 Reported difference thermal vs. 5 eV when using TOF or EAST -> check room backg. PLAN: agree on a set of root files to share and compare 1.3 Determination of prompt and delayed neutron background (Neut. Sensitivity) 1.4. Cristian reported on different TOF/EAST ratio for SILI (1.0) and MGAS (0.94)\ 1.5. Agreement (<3%) of B.I.F. from Claudia and Giusepe (52. vs. 53.6) 2. Huge oscillations above ~300 keV (also in FIMG): work on improved analysis routine? (compensation technique!!) 3. DIAM (10B) Is it possible that g-ray and neutron profiles have different centroids? Problem with activation measurement for B.I.F. Threshold? Efficiency?

  2. Open questions & Working plan 4. 241Am with C6D6 Check dead-time correction with lower threshold Conclude on findings fro delayed neutron background 5. 236U with TAC Need to check shape of beam-off background with conditions on mcr and Esum 6. Beam profile B.I.F. changes 10% between thermal and 10 keV. Is this realistic? (simulations…) Trend of B.I.F. surprising. (check something?) BIF(2011)= 1.15xBIF(2010) [Z position has changed? If not, problem!] Extrapolate results from XY-MGAS position to C6D^ and TAC samples positions 6. Res. Function Investigate the possibility to study the C resonance at MeVs (from DIAM) 7. Neutron sensitivity Work ongoing, ut walls and conclusions need to be reached before Christmas

More Related