html5-img
1 / 158

Biosensor

Biosensor. M. Fatih Abasıyanık. Biosensors are actively used in science Self- Monitoring of Blood Glucose with Glucose Sensor has a market (8.8 Billion Dollars in 2008) Biosensor : . Aim : . Understand the parts of biosensors How they work

amish
Télécharger la présentation

Biosensor

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Biosensor M. Fatih Abasıyanık

  2. Biosensorsareactivelyused in science • Self-Monitoring of BloodGlucosewithGlucose Sensor has a market (8.8 BillionDollars in 2008) • Biosensor :

  3. Aim: • Understandtheparts of biosensors • Howtheywork • To be abletodiscriminatebiosensorsaccordingtotheirquality • To be abletodesignnewbiosensors • To be abletodiscussthepapersaboutbiosensors • To be abletoimprovebiosensors • To be abletoclassifyresults of sensors.

  4. Contents • Introduction to Sensors • Transduction Elements • Sensing Elements • Performance Factors • Electrochemical Sensors and Biosensors • Photometric Applications • Mass-Sensitive and Thermal Sensors • Specific Applications

  5. Book • “CHEMICAL SENSORS AND BIOSENSORS”

  6. Sensor? • A device or organ • To detects certain external stimuli and responds in a distinctive manner

  7. Basic sensors • An acid turns blue litmus paper red and a base turns red litmus paper blue

  8. pH meter

  9. Types • Physical sensors: measure • Distance • Mas • Temperature • Pressure • Chemical sensors: measure • Chemical substrances by chemical or physical response • Biosensors: measure • Chemical substrances by using a biological sensing element. • All of them  connected to a transducer visible response occurs

  10. Chemical Sensors and biosensors detect chemicals called analyte. • If analyte is a biomolecule, the device can be called biosensor Recognation element

  11. Types of transducer • Electrochemical biosensor: mostly used • Potentiometric: measure potential • Voltammetric : an increasing (decreasing) potential is applied to the cell until Ox. (re.) of the substrance to be analysed occure and a sharp rise (fall) in the current to give a peak. • Conductometric • FET based • Optical • Piezo electric • Thermal

  12. İmmobilization

  13. Performance factors • Selectivity • Sensitivity • Accuracy • Response time • Recovery time • Lifetime

  14. Biosensor: BiorecognationUnit (Sensing Element; biologicdetectionunit)

  15. SensingElements • Itis concerned with various ways in which a sensor can recognizean analyte. • specific for that analyte alone, • Selective ;responding to the required analytemore than to other species. Types of SensingElements • İonic (chemicalsensors) • Molecular (chemical sensor andbiosensor) • Biological (biosensor)

  16. A- IonicRecognation: Ion-SelectiveElectrodes • Possibleto be used in biosensors. • Example: urea ammonia • Theyare based on the principle of the emf of a concentration cell. • A potentiometric device in which the change in emf is proportional to the logarithmof the analyte concentration. • The selectivity by the membraneseparatingthe analyte solution from the internal reference solution. 0.0 0.5

  17. Interferences • Sensorsrespondto one ion more than to others, although there is often a small response tounwanted ions. This is known as interference. • For example, • a fluoride ISEresponds to hydroxide at one tenth of the response level (to fluoride) for equalconcentrations of the ions. • The level of interference is measured by the selectivitycoefficient • kij=the selectivity coefficient. 0.0 0.5 0.1 ISAB (ionic-strengthadjustmentbuffer): [OH] declinedto 10-9M pOH:9 . it is lowerthandetection limit for OH

  18. A- IonicRecognation: ConductingDevices • ionsconductorforelectreicty • quantitymeasurement • resistance (1/conductivity) • conductancedepends on…..; • degree of ionization (storngorweak) • charge of ion • number of ions • mobility of ions (relatedto size, smallfastermoreconductive) • conductivity not usedalone • ionchromography (extensivily)

  19. A- IonicRecognation: Modifiedelectrodes • selectivityimportant • electrodes not selectivealone • togain a selectivitymodifythem • twoways • modifythemselves • modifyitssurfacecoatedwithpolymers • modifythemselves • bestexampleCPE(Carbonpasteelectrode) suitableelectrodegraphitepowderwithNugola stiffpaste   mixwith a modifiedcomponent (electroactive;such as ferrocene) or a complexingagentextractingelectroactiveanalyteintothesurface of thepaste

  20. A- IonicRecognation: Modifiedelectrodes • modifyelectrodesurfacebycoatingwithdifferenttypes of polymers • Mainly 3 types • conductingpolymers • ion-exchangepolymers • redoxpolymers • a) Conductingpolymers • moststudiedones: polyacetylene, polypyrrole, polyanilineandpolythiophene • easytopolymerize: electrochemicallyoxidizingthesubstrade on theelectrode. • solventsandcounterions effect on thepolymer

  21. B- MolecularRecognition: 1. ChemicalRecognitionAgents  Thermodynamiclyrxnto be controlled M= analyte L=RecognitionAgent • M-L complex, or M or L respondto a particulartransducer (optical, electrochemicaletc) • Opticalresponse: an absorptionorfluorescencechangetotheanalyte • PVC (polyvintylchloride) successfullyusedforsuchbiosensor (ion-selectiveelectrodesalso) • Potentiometic e. (used)

  22. SomeApplicationwithsuchrecognitinagents • Analyte: Iron (II) • RecognationAgent: 2,2’-bipyridyl in a poly (vinylpyridine) (PVP) membrane. • Method: iron(II) oxidizedbylinear-sweepvoltametry. • Complexationrxn (M-L) accumulation of iron • İndicators can be usedtoanalyzetheanalytes. • Optodes: Opticalbiosensors (colorimeterorspectrophotometer)…. Usedtodetectthecolourchange

  23. Molecular Size: • Iftheanalyte is smallerthantheothers in thesample, size is selectiveandmolecularsievesareused as recognitionagent. Examples: • Theantibiotic, valinomycin is a neutralionophore • Makingcomplexwithpotassiumionsselectively • K fitsintoitscavity • Valionmycinused as a recognitionreagenttodetect K

  24. B- MolecularRecognition: 2. BiologicalRecognitionAgents • Biologicalsystemsthemajorselectiveelements • Theymustattachthemselvestooneparticularsubstrate, but not toothers. • Enzymes • Antibodies • Nucleicacids • Receptors Affinitybiosensors: Sensorswithantibodies of receptors as RecognitionElements

  25. 1. Enzymes • Free (purified) Enzmyes • TissueMaterials • Micro-organisms • Organelles (Mitochondria)

  26. Enzymes A. PurifiedEnzyme Manyenzymesoxidation-reduction (electrochemically) S:substrate ; E: Enzyme; ES:enzyme-substratecomplex; P:product

  27. enzymes Michaelis-MentenEquation

  28. enzymes

  29. enzymes Double-reciprocal plot

  30. AdvantagesandDisadvantages of usingEnzymes in sensors ADVANTAGES DISADVANTAGES • Highlyselective • Catalyticallyactiveimprovesensitivity • Fairlyfast-acting • One of themostknownbiologicalcomponents • Expensive • A lossactivitywhenimmobilized on a transducer • Tendingtoloseactivityafter a relativelyshortperiod time

  31. enzymes B. TissueMaterials: • Tissuemultiplicity of enzymes • Thus, not selective as purifiedenzymes • But, longer life protected (in itsenviron.) • Responseslow (diffusion) • Cheaper • Example: Banana tissue sensor: • [Eggins (1997)] Banana biosensor

  32. enzymes • Fordopamine, a catcholaminefound in braincontaining a complex of polyphenolaseswhichcatalysetheoxidation of polyphenoliccompounds • İtsderivatives: flavanolsfound in beersandwine • Polyphenoloxidasecatalysetherxn. • İt is found in banana

  33. enzymes • Advantages: • Enzyme in naturalenvironment • Activitystable • Lessexpensive • Theysometimesworkwhenpurifiedenzymes fail • Disadvantages: • Lossselectivity • Diffusionproblems

  34. enzymes C. Microorganisms: • Theyplayimportant role in • Brewing • Pharmaceuticalsynthesis • Foodmanufacture • Waste-watertreatment • Energyproduction • MO immobilizedtotransducerdirectly • MO can ….. • Assimilateorganiccompounds • Produceelectroactivemetabolites

  35. enzymes • Advantages: • Cheaper • Lesssensitivetoinhibitonbysolutes, moretoleranttopH & temperature • Longerlifetimes • Disadvantages: • Longerresponse time • Longerrecoveryactivitytimes • Manyenzymesandlessselectivity

  36. enzymes D. Mitochondria (organelles) • Sub-cellularmulti-enzymeparticelscatalyze an analyte

  37. antibodies 2. Antibodies: • Versitile (largespectrum) • Possibletodevelopeforanyantigen • İtsfunction: tobind an invadingantigenandremove it fromharm

  38. Heavy chain hinges Fab: antigen-binding fragment light chain Fc: crystalizable F Gerald edelman & Rondey porter

  39. antibodies • Labelling Ab • Radioisotopes • Enzymes • Redcells (RBC) • Fluorescentprobes • Chemiluminescentprobes • Metal tags • Masschangeetcalso can be seen

  40. antibodies • Advantages: • Highselectivity • Ultra sensitive • Bindverypowerfull • TNT also can be detectedbyantibodies R.D. Shankaran, K.V. Gobi, K. Matsumoto, T. Imato, K. Tokoand N. Miura, Highlysensitivesurfaceplasmonresonanceimmunosensorforparts-per-trillionleveldetection of 2,4,6-trinitrophenol, Sens. Actuators B: Chem.100 (2004), pp. 425–430. • Disadvantages. • No catalytical

  41. nucleic acids 3. Nucleic Acids: • likeantibodies • DNA probesusedtodetectgeneticdiseases, cancersandviralinfections • DNA assays can involvetheaddition of labelled DNAtothesystem • Radioactive • Photometric • Enzymic • Electroactive

  42. nucleic acids • Examplesto NA biosensor

  43. 4. Receptors: • A receptor is a structure in a cell, which can trigger an amplified physiological response when it is bound to a particular ligand (an agonist). • An agonist a chemical binding to a receptor and triggers a response by the cell. An agonist often mimics the action of a naturally occurring substance.An agonist produces an action. An antagonist blocks an action of an agonist. The response may be either … • ion-channel opening, • production of second messenger systems, or • activation of enzymes.

  44. Receporstendtohave an affinityfor a range of structuralrelatedcompounds. • Likeothers, alsotheyarelabelled • Examples: • BiosensorforAnaestherics

  45. Transducers

  46. Types of transducers • ElectrochemicalTransducers • Potentiometric • VoltammetryandAmperometric • Conductivity • FieldEffectiveTransistors • PhotometricSensors • Others

  47. ElectrochemicalTransducers

  48. metal (such as silver) is placed in a solution containing ions (such as silver ions), there is a charge separation across the boundary betweenthe metal and the solution. an electronpressure, usuallytermed a porential. It cannot be measured directly, and requires two such electrode-electrolyte combinations. Each of these is called a half-cell.Such a combination is called an electrochemical cell

More Related