1 / 25

ME280 Fractional Order Mechanics

ME280 Fractional Order Mechanics. Fractional Analysis of Time Voltage Area of an EKG. Presenter : Marwin Ko. Motivation. Left ventricular hypertrophy (LVH ) is when the cardiac muscle in your left ventricle (LV) thickens causing your heart to work harder

anais
Télécharger la présentation

ME280 Fractional Order Mechanics

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ME280 Fractional Order Mechanics

  2. Fractional Analysis of Time Voltage Area of an EKG Presenter: MarwinKo

  3. Motivation • Left ventricular hypertrophy (LVH) is when the cardiac muscle in your left ventricle (LV) thickens causing your heart to work harder • Time-voltage area was calculated detect (LVH) • Important because the LV is responsible for oxygenated blood being pumped throughout the whole body

  4. Background Information Heart Rate (HR) – beats per minute Heart Rate Variability (HRV)– variation in the time interval between heartbeats

  5. SA AV B-His

  6. How can we get HRV data?

  7. PhysioNet PhysioBank: “Archive of digital recordings of physiologic signals…and other biomedical data.” • Obtained 3 sets of data • MIT-BIH Normal Sinus Rhythm Database • MIT-BIH Arrhythmia Database • MIT-BIH Sudden Cardiac Death Database PhysioToolkit: “Library of software for physiologic signal processing and analysis…” • Multiple errors occurred in MATLAB when running PhysioToolKit for MATLAB. • Used “rddata.m” to convert data files into readable data for MATLAB also includes an embedded QRS detector

  8. Code Outline • Run EKG data • Run for one minute per data set • Show area of interest • Using -0.8mV as a baseline (resting electric potential) • Calculate area per interval • Manually find peaks (data sets of about 100 data points) • Run Hurst Estimators • Aggregated Variance Method • R/S Method

  9. Code Outline • Run EKG data • Run for one minute per data set

  10. Code Outline • Show area of interest • Using -0.8mV as a baseline (resting electric potential)

  11. Code Outline • Calculate area per interval • Manually find peaks (each data set approximately 100 data points) R R R R Time Series!

  12. Code Outline • Run Hurst Estimators (the other Methods did not work well with the small data set) • R/S Method • Aggregated Variance Method

  13. Hurst Estimator • Heart rate variability is a long range dependent time series! • Do not have that much data to work with… • Using the R-R areas as a time series data set, thus avoiding periodic data set which the Hurst estimator is sensitive to • H<0.5  Volatile process (non-persistent) • H=0.5  Non-correlated process (randomness) • H>0.5  Corresponds to a trending (persistent) process

  14. Data Utilized • One minute long portions were used • Three EKG readings were used: • Arrhythmia (92 beats/min, 91 R-R interval) • Sudden Cardiac Death (97 beats/min, 91 R-R interval) • Normal Sinus Rhythm (89 beats/min, 91 R-R interval) • Normal Sinus Rhythm data would not compile via MATLAB code provided by PhysioNet • As a result, I used a patient from the arrhythmia data set who exhibited normal sinus rhythm episodes.

  15. Data Utilized Normal Arrhythmia Sudden Cardiac Death

  16. Normal Sinus Rhythm H=0.7393 H=0.4746

  17. Arrhythmia H=0.8873 H=0.8726

  18. Sudden Cardiac Death H=0.6878 H=0.6194

  19. Hurst Estimator:Aggregated Variance Method Normal Arrhythmia Sudden Death H=0.8726 H=0.4746 H=0.6194 H<0.5  Volatile process (non-persistent) H=0.5  Non-correlated process (randomness) H>0.5  Corresponds to a trending (persistent) process H>0.5  Corresponds to a trending (persistent) process

  20. Hurst Estimator:R/S Normal Arrhythmia Sudden Death H=0.8873 H=0.7393 H=0.6878 H>0.5  Corresponds to a trending (persistent) process H>0.5  Corresponds to a trending (persistent) process H>0.5  Corresponds to a trending (persistent) process

  21. Conclusion • Normal Sinus Rhythm • Inconclusive results, need to run real “Normal Sinus Rhythm” EKG data. • Arrhythmia • Both results have H>0.5 • Trending towards the tachycardia (high heart rate) • Sudden Cardiac Death • Both results have H>0.5 • Trending towards the erratic EKG signal • Need more data for more conclusive results!

  22. Future Plans • Find a better way to obtain the data sets • “R” peaks were all manually found using MATLAB figures • Trouble shoot PhysioNet data converter code • Test out other Hurst Estimators, once bigger data sets are available

  23. Thanks & Appreciation • Dr. Chen • Zhou Li • Taizhi Lyu

  24. Questions?

  25. References • Goldberger AL, AmaralLAN, Glass L, Hausdorff JM, Ivanov PCh, Mark RG, Mietus JE, Moody GB, Peng C-K, Stanley HE. PhysioBank, PhysioToolkit, and PhysioNet: Components of a New Research Resource for Complex Physiologic Signals.Circulation101(23):e215-e220 [Circulation Electronic Pages; http://circ.ahajournals.org/cgi/content/full/101/23/e215]; 2000 (June 13). • Goldberger AL, Amaral LAN, Glass L, Hausdorff JM, Ivanov PCh, Mark RG, Mietus JE, Moody GB, Peng C-K, Stanley HE. PhysioBank, PhysioToolkit, and PhysioNet: Components of a New Research Resource for Complex Physiologic Signals.Circulation101(23):e215-e220 [Circulation Electronic Pages; http://circ.ahajournals.org/cgi/content/full/101/23/e215]; 2000 (June 13). • Goldberger AL, Amaral LAN, Glass L, Hausdorff JM, Ivanov PCh, Mark RG, Mietus JE, Moody GB, Peng C-K, Stanley HE. PhysioBank, PhysioToolkit, and PhysioNet: Components of a New Research Resource for Complex Physiologic Signals.Circulation101(23):e215-e220 [Circulation Electronic Pages; http://circ.ahajournals.org/cgi/content/full/101/23/e215]; 2000 (June 13). • Boron, Walter F., and Emile L. Boulpaep. Medical Physiology. 2nd ed. Philadelphia, PA: Saunders, 2012. Print. • Rose, 0. "Estimation of the Hurst Parameter of Long-Range Dependent Time Series."University of Wurzburg Institute of Computer Science Research (1996): 1-15. Web. 22 Nov. 2013. • Markovic, D., and M. Koch. "Sensitivity of Hurst Parameter Estimation to Periodic Signals in Time Series and Filtering Approaches." Geophysical Research Letters (2005): 1-10. Web. 15 Nov. 2013. • Leite, A., AP Silva, S. Gouveia, J. Carvalho, and O. Costa. "Long-Range Dependence inHeart Rate Variability Data: ARFIMA Modelling vsDetrended Fluctuation Analysis."IEEEXploreDigital Library (2007): 1-4. Print. • http://www.mathworks.com/matlabcentral/fileexchange/19148-hurst-parameter-estimate • http://www.mathworks.com/matlabcentral/fileexchange/13188-shade-area-between-two-curves • http://www.myschoolhouse.com/courses/O/1/94.asp

More Related