Some Common Backflow Preventer Installation Mistakes

When it comes to the installation of a backflow preventer, you cannot rely on just any backflow prevention services provider because an improper backflow preventer installation can create several problems. So, take your time, and hire an expert backflow prevention services provider for your needs.

Télécharger la présentation

Some Common Backflow Preventer Installation Mistakes

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. SOME COMMON BACKFLOW PREVENTER INSTALLATION MISTAKES

  2. At More than Five Feet Height from the Ground A backflow preventer must be installed lower than five feet from the ground. If its height is more than 5 feet, it will create issues in testing, maintenance, and repair. Also, it will create the risk of injuries to the tester. When a backflow preventer is installed at a lower height, the inspector can easily examine the backflow preventer and fix any issues. Green Thumbs Garden Cafe | Gardening for Food

  3. Installing a Reduce Pressure Backflow A reduce pressure backflow preventer must be installed close to a floor drain. Otherwise, the relief valve may leak. If you want to avoid any damage due to water, you should make sure the relief port is connected to a drain pipe of adequate size and terminated with an indirect connection above the floor drain. Besides, an air-break should be installed above the floor drain. Green Thumbs Garden Cafe | Gardening for Food

  4. No Y- Strainer Upstream A Y-strainer upstream is mandatory to be installed with a backflow preventer. It will remove solid wastes from the water system and reduce contamination risk. Besides, it does not allow the waste to reduce the efficiency of your backflow preventer. Green Thumbs Garden Cafe | Gardening for Food

  5. Clearances must be respected; otherwise, the test cock can be out of Clearances reach. There must be sufficient space for your hands to use the tools, separate different parts to inspect them and replace them if required. Green Thumbs Garden Cafe | Gardening for Food

  6. CONNECT WITH US Apna Fire & Electrical Service LTD. 8114 123 STREET SURREY, BC V3W 8P8 info@apnafireelectrical.ca 778 903 7195 https://apnafireelectrical.ca/ Green Thumbs Garden Cafe | Gardening for Food