Magnetic Field and Magnetic Shielding R&D

Magnetic Field and Magnetic Shielding R&D. The next 15 months. Goals Develop coil structures from non-conducting materials. Test active B-field shielding for dressing coils with 1/7 scale prototype

asasia
Télécharger la présentation

Magnetic Field and Magnetic Shielding R&D

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Magnetic Field and Magnetic Shielding R&D The next 15 months • Goals • Develop coil structures from non-conducting materials. • Test active B-field shielding for dressing coils with 1/7 scale prototype • Test superconducting shield in 1/7 scale prototype (@ 4K including B0 coil and ferromagnetic shield) • Construct ½ scale B0 coil and demonstrate scaled uniformity and gradient specs • Upgrade Tosca for eddy-current calculations • Construct test dewar for 4K vertical and horizontal measurements for ½ scale B0, and 3He holding coils • Build high-field holding coil for injection tests B. Filippone 10/7/06

  2. New Coil Structures • Jan B. has been working on composite structures for coil fabrication • Use these to construct ½ scale B0coil and ferromagnetic shield part of previous R&D – 17k$ submitted 4/11/06 – “approved” 9/25/06 • Measure coil field uniformity shoot for

  3. Active shielding for Dressing Coil • Construct dual active shielding @ 1/7 scale • New capital • Fabricate coil • Additional fluxgate magnetometer • Additional power supply and readout

  4. Superconducting Shield • 1/7 scale prototype SC shield to be used with existing cosq coil and ferromag. Shield • Initial tests with fluxgate magnetometer • Test with SQUIDs if possible (Collaborate with LANL or purchase ~ 12 k$ • Requires upgrade to existing dewar, temp. readout, LHe

  5. Cosq coil for 3He R&D project • Construct 1 m long, 30 cm diameter coil • 20 gauss max. field • Average gradients < 5 mg/cm • Requires • Support structure • SC wire • Vaper-cooled power leads • Power supply Dima’s Idea Try 1kG magnet Gives much larger NMR signal

  6. Other Items • TOSCA upgrade for ASU (Electra and extra license) • Magnetic Mapper upgrade

  7. Cost Summary • 20 gauss R&D coil (hi –B??): 26k$ • SC shield prototype: 20k$ • Active shield prototype: 18k$ • TOSCA upgrade: 8k$ • ½ scale test Dewar: 30k$ • Mag. Mapper upgrade: 3k$ 105k$ Try to beg/borrow or steal HTS or LTS SQUIDS Buy ~ 15k$ Above includes ~ 20k$ machinist, 85k$ equipment

More Related