An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Update on GMSB Conversion Efficiency Studies Informal Non-Pointing Photon Group April 22 2009 Bruce Schumm, UCSC/SCIPP

  2. Data Samples Need to find adequate release for studying conversions Thomas Koffas: 14.2.25.X, for X > 6, should be fine Use photon list only; converted photons are flagged GMSB1 GMSB2 14.2.20.3 (~10K events) 14.2.25.6 (~ 8K events) 14.5.0 (~ 1K events) 14.2.25.8 (~10K events) (All of these available as AOD except 14.5.0, which I reconstructed from RDOs.) NOTE: Relative to GMSB1, GMSB2 reconstructed in different release(s), and has non-pointing photons (two things change at once)

  3. Efficiency Calculation • Efficiency denominator: • True conversions for which the photon • Descended from the decay of a SUSY particle • has p > 10 GeV/c • has a radius of origin less than 500mm • has || < 1.37 • Is not a brehmstrahlung photon • Also, can add a “grav” requirement: • converted photon directly from   Gravitino +  •  Always true for GMSB1

  4. Efficiency Calculation • Efficiency numerator: • Strict truth-matched reconstructed photon conversions: • 1-Track Conversions: Track must truth-match to an electron from a conversion • 2-Track: Tracks must truth-match to one electron and one positron that arise from a single conversion. • No other requirements, except that conversion must be on official photon list.

  5. Efficiency for All GMSB Photons Deficit? Deficit? Deficit?

  6. Restrict GMSB2 to  Gravitino Decays Deficit? Deficit?

  7. Parting Thoughts • Indirect evidence for: • Degraded efficiency at high Rorg if you don’t use 14.2.25.X; X>6 • Degraded performance for non-isolated phonts (non-”grav” photons may not be isolated) • Degraded performance for non-pointing photons • BUT: Too many things changing at once to be sure. Need to consult/get control of reconstruction version. • (ALSO: Have signed up with egamma group that is re-optimizing conversion selection…)