180 likes | 311 Vues
This documentation presents the initial conditions and commissioning data from the COM1 project, focusing on spectral calibration challenges and bad pixel maps. The analysis covers two datasets of 31ms and 107ms utilizing Amdlib v0.106 and Fourier software from MPIfR, with a spectral range of 2100-2230nm. Significant focus is given to the calibration of visibilities, assessing signal accuracy, and SNR selection. The effects of calibration methods on the derived scientific values are also explored, providing essential insights for astrophysical interpretations.
E N D
MWC 297 Data Reduction M. Benisty, F. Malbet (LAOG) S. Kraus (MPIfR)
Initial conditions • Commissioning Data from COM1: • No spectral calibration • Initial bad pixel maps • 2T data only • 31ms and 107ms data set • Amdlib v0.106 and Fourier software at MPIfR • Spectral range: 2100-2230nm • Two calibrators: HD152880 and HD177756
Published values • Vcont = 0.50+0.08 • Vline = 0.33±0.06 -0.05