1 / 39

Polarization at HERA Fabio Metlica ( Penn State University) ZEUS Students Seminar 06/06/03

Polarization at HERA Fabio Metlica ( Penn State University) ZEUS Students Seminar 06/06/03. Polarization at HERA. Physics with Polarized Lepton Beams The HERA Upgrade => HERA II Polarization at HERA HERA Polarimeters: TPOL and LPOL Summary.

barto
Télécharger la présentation

Polarization at HERA Fabio Metlica ( Penn State University) ZEUS Students Seminar 06/06/03

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Polarization at HERA • Fabio Metlica • (Penn State University) • ZEUS Students Seminar • 06/06/03 Polarization at HERA , F. Metlica

  2. Polarization at HERA • Physics with Polarized Lepton Beams • The HERA Upgrade => HERA II • Polarization at HERA • HERA Polarimeters: TPOL and LPOL • Summary Polarization at HERA , F. Metlica

  3. HERA II: Physics with Polarized Lepton Beams The study of polarized lepton (e+/e-) proton deep inelastic scattering at high will be one of the main physics topics at HERAII. Accurate polarization (P0.7) measurement together with high luminosity opens a new field for HERA physics at high . Possibility to study the chiral structure of the SM: -Charged currents: only LH particles interact -Neutral currents: LH, RH particles interact with Z unequally • Electroweak physics: study EW interactions using the 4 possible combinations: e-, e+ with P<0 and P>0. (Future Physics at HERA workshop). -Polarized NC,CC cross section measurements; -Light quark couplings to the Z-boson; -Precise measurements of EW parameters. • QCD: G2 structure function • Search for new physics: physics beyond SM -Right handed charged currents -Leptoquarks Polarization at HERA , F. Metlica

  4. Polarized NC, CC Cross Sections Investigate EW physics: NC and CC cross section measurements at high with P>0, P<0. Cross sections for NC and CC }X(p`) }X(p`) Polarization at HERA , F. Metlica

  5. Light Quark Couplings to the Z Boson • Polarization effect is large on cross sections for . • Different behavior at high due to Z exchange. • Split up to factor 2, at . • Exploit difference to extract the light quark(u,d) couplings to the Z-boson. Neutral Current x=0.2 Polarization at HERA , F. Metlica

  6. Light Quark Couplings to the Z Boson • Measurement of polarized NC,CC disentangle the light quark(u,d) couplings to Z. Done by using all four charge/polarization combinations. • Unpolarized DIS with e-/e+ beams axialcouplings. • Polarized DIS with the 4 charge/ polarization combinations vector couplings. 1 Contours for NC Couplings for Different Polarizations u coupling fixed d coupling fixed Polarization at HERA , F. Metlica

  7. Light Quark Couplings to the Z Boson • With of data equally divided between e+/e- and P=±0.7: • Based on full MC simulation; detector improvements would improve precision. • Complementary to LEP measurements with heavy quarks and similar to LEP precision for heavy quarks. u,d couplings to Z-boson Polarization at HERA , F. Metlica

  8. Measurements of EW Parameters: • Free parameters in SM • Measure constrain  • data from NC/CC cross sections with • beam polarization  • Test of EW universality. • LH gives highest precision: cross section largest. • High Pol. is worth a factor 4 in Lumi for NC. Polarization at HERA , F. Metlica

  9. Measure G2 Structure Function • structure function arising from Z interference. • G2 can be measured from the neutral current parity violating asymmetry  = degree of polarization (P)= axial charge of electron • Simulation for P=50% with for each polarization setting: G2 can be well measured at high x (M. Klein DIS2001 Bologna). x1 Polarization at HERA , F. Metlica

  10. Search for Right Handed CC • Standard model: only LH CC exists • Cross section vanishes for purely • RH electron (for P=+1): LHCC RHCC For e+ reverse sign Polarization at HERA , F. Metlica

  11. Search for Right Handed CC • Set a limit on the mass of the hypothetical boson (model dependent) • (~250 data). • Direct search. • Need high polarization 50%, and • precise polarization measurement. e-p SM MC e+p SM MC Polarization at HERA , F. Metlica

  12. New Physics: Beyond SM • Polarization is a useful tool for searching new physics signals. • SM backgrounds can be reduced (turned off) by varying the degree of polarization. If new physics have different couplings, the S/B will be increased. • Helps determine properties of newly discovered particles. • Study chirality of new particles e.g. leptoquarks. Polarization at HERA , F. Metlica

  13. HERA II • HERA UPGRADE: increase luminosity and provide longitudinal lepton beampolarization to the colliding experiments. Long shutdown 2000-2001, to modify IP and install spin rotators. LUMINOSITY UPGRADE • Strong focusing at IP:major changes of machine lattice near IP. Sets of superconducting quadrupoles installed close to the H1/ZEUS IP, inside the detectors. • Design luminosity HERA I (achieved): • Delivered by HERA I: (during 1992-2000) • Design luminosity HERA II : • To be delivered by HERA II by end 2006: (original plan, now?) Likely startup value for lumi: IP AREA Polarization at HERA , F. Metlica

  14. POL2000 Group: Polarization Upgrade • ZEUS: TPOL position sensitive detector(silicon microstrip + fiber detector)IC-London and Tokyo Metropolitan University • H1: LPOL cavity and fast DAQ for TPOL • HERMES: LPOL operation • HERA: polarized lepton beam studies and operation Polarization at HERA , F. Metlica

  15. HERA II: Polarization • In HERA leptons become transversely polarized through the emission of synchrotron radiation (spin flips): Sokolov-Ternov effect. • The transverse polarization is converted into longitudinal polarization near the interaction points by Spin Rotators (HERA I: HERMES; HERA II also H1/ZEUS) . • The lepton beam transverse polarization is measured by the TPOL polarimeter, and the longitudinal polarization is measured at the LPOL polarimeter, independently. Polarization at HERA , F. Metlica

  16. Polarization • Polarizationis defined as: • Polarization has to be known at the same level of precision as Total Luminosity, because it enters linearly in the cross section for many processes e.g.: • Polarization precision goal for HERA II: 0.01 ( 0.02-0.04 for HERA I), needed for polarization physics. • The absolute value of the degree of lepton polarization is the same along the whole ring. The actual location of the polarization measurement is not confined to the experiment IP. • Precise measurement from the TPOL/LPOL polarimeters together with machine lattice simulations, will provide confidence of having an accurate P measurement at IP. Polarization at HERA , F. Metlica

  17. Polarization • Polarization builds up and settles asymptotically to an equilibrium value. HERA I • Theoretical max polarization 92%, but reduced by counteracting depolarizing effects (dependence on ring parameters), • each spin rotator pair reduces polariz ~3%. • HERA I: 55%-65% polarization • HERA II : startup 50% polarization (aim for more 60%). Spin rotators and different lattice setups reduces polarization. HERA I Polarization at HERA , F. Metlica

  18. Polarization Measurement • The polarimeters make use of the spin-dependent cross section for Compton scattering of polarized photons on polarized leptons(e+/-) : • Alternatively L/R (~100Hz) circularly polarized laser light is scatteredoff leptons . The produced Compton photons are backscattered (in lab frame) into a narrow cone centered around the initial lepton direction and are detected by the polarimeter (LPOL or TPOL). • The Compton beam size at the TPOL is: Polarization at HERA , F. Metlica

  19. Polarization Measurement The polarization at HERA is determined by measuring asymmetries. LPOL TPOL Polarization at HERA , F. Metlica

  20. Polarization Measurement • The polarization of lepton colliding and non-colliding bunches differs (measured by LPOL at HERA I). Depends on the machine polarization tuning and varies in time (beam-beam effects). • Need accurate per bunch per minute polarization measurement  LPOL and TPOL upgrade for HERA2. HERA I LPOL Polarization at HERA , F. Metlica

  21. Polarization: TPOL TPOL upgrade completed • Fast DAQ to measure the polarization of individual bunches per minute. • Radhard silicon position sensitive detector to allow in-situ eta-y calibration. • TPOL ready for polarization measurement. Laser room 9th floor HERA B TPOL Setup (similar setup for LPOL) HERA Tunnel HERA B TPOL Lepton direction Polarization at HERA , F. Metlica

  22. TPOL-Spatial Asymmetry • Spatial asymmetry: • The typical total average vertical shift is about 0.15 mm. • In practice is obtained by measuring the up-down calorimeter energy asymmetry of the Compton photons: • determined by the calibration MC + test beam data. • transformation is of primary importance (main source of systematic error). test beam data Polarization at HERA , F. Metlica

  23. TPOL: HERA I • TPOL: Tungsten scintillator sampling calorimeter, 10W CW laser alternating LCP, RCP at 90Hz . • Operated in Single -photon mode: 1 photon per 200 bunch crossings; Compton energy spectrum of TPOL (HERA1) Compton spatial distribution at TPOL (HERA1) Polarization at HERA , F. Metlica

  24. Upgraded TPOL • TPOL calo measures: total energy . ,vertical position Yof the Compton  by the transformation. • Silicon detector: improve position resolution from ~1 mm (calo) to better than 50 m (silicon); intrinsic silicon resol. is 24m. • Transformation: determine accurately in-situ in real time, do not have to rely on test beam data. • Silicon position sensitive detector: prototype (1cm*1cm), final setup (6.3cm*6.3cm) (IC-London). • A single scintillating fiber detector for position calibration (5m) and monitoring of the Si-detector (Tokyo Metro. Uni). TPOL calo: Tungsten scintillator sampling calorimeter. Laser: 10W CW laser alternating LCP,RCP 90Hz . Polarization at HERA , F. Metlica

  25. Prototype Silicon Detector for TPOL • Prototype silicon detector:1cm*1cm, APV25 readout chip. • Tested with DESY T22 test beam (6 GeV electrons). Landau distr. • Results in ZEUS Note: ZEUS-01-019 • Strips S/N  20, Efficiency  97% • Position resolution < 50 m (beam telescope). • Good Eta-Y measurement Polarization at HERA , F. Metlica

  26. Silicon Detector for TPOL • CERN test beam: 6-50 GeV • Si detector(6.3cm*6.3cm),readout by 6 APV25, 80m pitch • Spare TPOL calo. (tungsten-scintillator sampling) • Scintillating fiber Detector: (7cm,1mm) • precision stage motor (reso. ~1 m). CERN test beam results and upgraded TPOL setup in ZEUS Note: ZEUS-02-019 Polarization at HERA , F. Metlica

  27. CERN Test Beam Results Good eta-y Non-Linearity:<1% Fiber calib. Precis:~50m Resolution:~ 25%/sqrt(E) Polarization at HERA , F. Metlica

  28. TPOL: HERAII Data Silicon event Silicon Raw data signal Polarization at HERA , F. Metlica

  29. Silicon Detector for TPOL Silicon 80m Pitch Adaptor 44m->80m Silicon APV25 44m Polarization at HERA , F. Metlica

  30. TPOL in HERA Tunnel Open TPOL( Calo+Silicon+Fiber) TPOL BOX Polarization at HERA , F. Metlica

  31. LPOL No major change: Original LPOL operational • Two calorimeters (Crystal and Sampling ) which may be used alternatively (movable support tables). Change to sampling: better energy linearity. • Pulsed laser: operates in Multi-photon mode: approx. 600 to1000 Compton photons produced per laser pulse (~100 Hz) shot on a lepton bunch. • Measure shifts of energy spectra for the two light polarizations. • Large difference in the spectra close to the Compton edge. • LPOL ready for polarization measurements. RCP LCP Polarization at HERA , F. Metlica

  32. LPOL Cavity Upgrade in Progress LPOL upgrade: New more powerful laser system ( Fabry-Perot cavity + new laser) to operate in single photon mode (~1-2 photons per bunch crossing). Large laser photon flux: increase probability of Compton scattering. • 1) direct calibration with Compton edge (define energy scale of calo) • 2) improve statistical error by having a high average laser power ~10kW (not commercially available). LPOL Cavity IP HERMES Lepton direction LPOL IP CW laser Original LPOL IP Circular polarized laser light Linear polarized laser light Polarization at HERA , F. Metlica

  33. LPOL Cavity (Orsay) • The cavity has been successfully installed during shutdown in HERA tunnel (near HERMES). • Cavity is locked and stable (gain factor ), should be ready by end of shutdown. • Startup plan: start with original LPOL setup, then move to laser cavity setup. Polarization at HERA , F. Metlica

  34. LPOL Cavity Installation in HERA Tunnel, 2003 Polarization at HERA , F. Metlica

  35. HERA Polarization Tuning 2003 • High polarization, P~50%, with all 3 • spin rotators on and colliding beams. • Both LPOL and TPOL working, and in reasonable agreement. TPOL minor technical problems: low TPOL luminosity. Polarization at HERA , F. Metlica

  36. Polarimeter Online Java Display Displays various polarization info Polarization at HERA , F. Metlica

  37. Polarization Data for ZEUS • Allpolarimeter info is stored into the ORACLE database. Accessible to all HERA experiments. • Software developed (Arafat Gabareen) to read polarization data from ORACLE and integrate it with the rest of the ZEUS data. • Polarization data integration: during ZEUS event reconstruction, typically a few days or a week after the data is taken. • Two ADAMO tables: 1)TPOL and LPOL values P,P for all 220 bunches. 2)TPOL and LPOL values P,P average for colliding and non-colliding bunches. Polarization at HERA , F. Metlica

  38. Extra Info • e+e- 4-6 weeks. Orbits differ, magnets need to be moved by ~6mm. • Longitudinal Polarization flip: ~1-2 days. HERA1 (LPOL) done once a month during access day (mechanical movement of magnets) plus time for beam polarization tuning. • Longitudinal Polarization direction (P<0 or P>0): each experiment can choose independently. • Polarimeters: no background problem seen. No lattice modification carried out at polarimeter locations, backgrounds similar to HERA1. • Lepton transverse polarization did not affect the measurements at HERAI (H1/ZEUS). suppressed to order compared to . (Does Transverse Electron Polarization Affect Measurements at HERA? M. Kraemer et. al.) Polarization at HERA , F. Metlica

  39. Summary • HERA has been upgradedHERAII: - luminosity increase - lepton beam polarization P50% with P/P ~1% (upgraded polarimeters). • New field of HERA physics is opened with polarized lepton beams. • Two polarimeters LPOL(cavity upgrade to be completed) and TPOL to provide accurate polarization measurements to the HERAII experiments. • Polarimeters will operate independently and cross check one another; together with HERAII machine lattice simulations will provide confidence in the IP polarization value. • TPOL/LPOL working, measured 50% polarization before start of shutdown. • Discussion between experiments and DESY to organize running and maintenance of the polarimeters. Polarization at HERA , F. Metlica

More Related