冰水主機 : 壓縮機 冷凝器 冰水器
DESCRIPTION
冰水主機 : 壓縮機 冷凝器 冰水器. 高壓手控閥 : 控制高壓高溫氣態冷媒流入冷凝器. 油過濾器 : 負責壓縮機潤滑油之過濾. 卸載電磁閥 : 1. 啟動運轉 150 秒內卸載 2. 溫度到達設定值後卸載. 角閥 ( 出液閥 ): 1. 位於冷凝器出口 控制液態冷媒 2. 壓縮機做泵集時須關閉此閥. 過濾乾燥器 : 過濾液體管中冷媒之水份及雜質. 液體管手控閥 : 1. 控制液體管中之冷媒 2. 更換過濾乾燥器時須關閉此閥. 感溫式膨脹閥 : 控制液態冷媒流入冰水器中 , 其感溫棒位於冰水器出口處.
1 / 36
Télécharger la présentation
冰水主機 : 壓縮機 冷凝器 冰水器
An Image/Link below is provided (as is) to download presentation
Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.
Content is provided to you AS IS for your information and personal use only.
Download presentation by click this link.
While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.
During download, if you can't get a presentation, the file might be deleted by the publisher.
E N D
Presentation Transcript
高壓手控閥: 控制高壓高溫氣態冷媒流入冷凝器
油過濾器: 負責壓縮機潤滑油之過濾
卸載電磁閥:1.啟動運轉150秒內卸載2.溫度到達設定值後卸載卸載電磁閥:1.啟動運轉150秒內卸載2.溫度到達設定值後卸載
角閥(出液閥):1.位於冷凝器出口 控制液態冷媒2.壓縮機做泵集時須關閉此閥
液體管手控閥:1.控制液體管中之冷媒2.更換過濾乾燥器時須關閉此閥液體管手控閥:1.控制液體管中之冷媒2.更換過濾乾燥器時須關閉此閥
感溫式膨脹閥:控制液態冷媒流入冰水器中,其感溫棒位於冰水器出口處感溫式膨脹閥:控制液態冷媒流入冰水器中,其感溫棒位於冰水器出口處
高低壓開關:高壓開關:設定值19 Kg/cm2 (270 Psig)低壓開關:設定值3.2 Kg/cm2 ( 45 Psig)
水流穩定保護計時器 延後啟動計時器 Y 啟動計時器 卸載啟動及運轉計時器
冰水器 冷凝器
冰水器 冷凝器
週邊設備開關箱: 冷卻水泵 冰水泵 空調箱 冷卻水塔