An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. St. Elizabeth Fire Protection System 100% Fire Sprinkler Coverage 100% Heat/Smoke Detector Coverage

  2. Course Objectives • Familiarization of system • Locations of: Hydrants FDC Knox Box FACP Sprinkler Riser Room Liquid Oxygen • Unique Fire Protection Element Smoke Curtain Kitchen Hood System Standpipe Pre Action & VESDA Systems

  3. Hospital Grounds NORTH Ambulance Entrance Main Entrance Fire Dept. Connection Knox Box Enunciator Panel Sprinkler Riser Room Standpipe Roof Acess

  4. Fire Department Connection Located on Jensen St. Side Of Hospital You will need the knox key to remove the caps on the FDC

  5. Knox Box To access Key use door code followed by #

  6. Fire Alarm Control Panels FACP located on floor one in boiler room. Annunciator panels located on all floors. Printer located near FACP prints all activity associated with fire systems

  7. BRAIN(Fire Pump Control Panel) HEART(FIRE PUMP) Blood Vessels(Piping) CPR Nervous System

  8. Sprinkler Riser Room Floor 1 Riser/Standpipe Double Check Valve Water In Test Header Always Closed Pump Bypass Always Open Floor 2,3 & Roof Riser/Standpipe Back To Riser Fire Pump Jockey Pump

  9. Standpipe Flow Switch Floor 2 Isolation Valve Isolates 2nd floor Sprinklers 2 ½ Inch Connection Isolation Valve Will Turn off water to floors 2 & 3

  10. StandpipeNorth Stairwell 2 ½ “ Connection Both Are Supplied From Sprinkler System

  11. Roof Top Ceiling of south Stairwell Roof Standpipe PIV Roof Access South Stairwell Dry Beyond Valve Roof Standpipe PIV

  12. Kitchen Hood System Kitchen Hood Flow Switch Is Tied Into The Fire Alarm System

  13. Fire Curtain Separation Located outside every elevator door. Curtains are activated with fire alarm or sprinkler water flow

  14. Located near stairway/ atrium on floor one. Activated with fire alarm or water flow. In place to prevent smoke migration between floors.

  15. Generator Generator Located Here

  16. Underground Fuel Storage Underground tank contains approximately 3,000 gallons of diesel fuel.

  17. Liquid Oxygen Tank

  18. Pre-Action System & VESDA System Pre Action Located In ClosetFloor 2VESDA Located On Floor 1 in MRI Area SolenoidHolds Water Back VESDA Similar To Pre Action. Goes Into Pre Alarm Notifying Staff Well In Advance Of Actual Fire. Air Compressor Loss Of Air Pressure Plus Activation Of Smoke Detector Required For Water To Enter The Sprinkler Piping

  19. This Has Been A C-SHIFT Production