Blanco Instruments 2004-2008

Blanco Instruments 2004-2008. Instrument 2004 2005 2006 2007 Replacement Mosaic 8K CCD Imager yes yes yes yes ISPI 2K IR Imager yes yes -- -- NEWFIRM NEWFIRM 8K IR Imager share share HYDRA MOS (Fiber) yes yes yes: yes: RC Spectrograph yes (SOAR)

belle
Télécharger la présentation

Blanco Instruments 2004-2008

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Blanco Instruments 2004-2008 Instrument 2004 2005 2006 2007 Replacement Mosaic 8K CCD Imager yes yes yes yes ISPI 2K IR Imager yes yes -- -- NEWFIRM NEWFIRM 8K IR Imager share share HYDRA MOS (Fiber) yes yes yes: yes: RC Spectrograph yes (SOAR) Echelle Spectrograph yes ? ? (SOAR)

  2. Southern Hemisphere US facilities 2004-2008 • SOAR 4.2-m -> 6 x 6 arcmin field, Adaptive optics • Gemini 8m -> narrow-field MOS spectroscopy + OIR instruments, MCAO. Second generation instruments (2008-2009) still to be defined; may include KAOS. • Magellan 6.5-m (x 2) -> One telescope will have F/5 (like MMT), share Megaprime (24x24 arcmin) • SALT 11-m -> spectroscopy, specialized, no public time anticipated

  3. Mosaic II Plusses • Good site, good telescope, good photometry • Reliable - (except we have a failed CCD) • Rapid filter change (< 10 seconds), lots of filters, fast shutter (10 ms uniformity) Minuses • Image quality issues - telescope, corrector, environment? • Slow readout (1.5 minutes in 16-channel mode) • Capable, but complex data acquisition system - both hardware and software SPIE 3355: CCDs - 487, Software - 497, Hardware -577 (1998)

  4. Mosaic II - Improvements? • Replace the failed CCD (March 2004) • Improve the telescope imaging performance • Telescope primary mirror radial supports • Telescope active optics system • Dome environment • Evaluate corrector performance • Pipelines for data reduction • Data into NOAO archive

  5. Performance metrics “LSST” metrics: (a) Faint Time window: A   / (psf)  1/2 (b) Faint stellar: A   / (psf) 1/2 (c) Faint resolved galaxies: A   / 1/2 Where sky noise limited exposures are assumed in all cases, and A = Telescope primary area  = Detector area  = efficiency (everything from clouds to readout time) (psf) = area of stellar point spread function  = cycle time  = background sky brightness

  6. Performance Comparison Faint Galaxy Performance: (A / 1/2) LSST: 79 PanSTARS: 15 CFHT Megacam: 2.7 Subaru: 2.2 SDSS: 1.7 VST: 1.4 VISTA (IR): 0.93 CTIO 4m + Mosaic: 0.9 CTIO 4m + DEC (2deg2) 11