An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Reactor Accidents Noteworthy LOCA Events

  2. Light Water SL-1 Millstone 1 Browns Ferry 1 and 2 Three Mile Island 2 ** Ginna Mihama 2 Chernobyl ** Heavy Water NRX Lucens Gas Cooled Windscale St. Laurent Hunterston B Hinckley Point B Liquid Metal EBR-1 Enrico Fermi ** Will be Covered in Upcoming Lectures Loss of Cooling Accidents

  3. Stationary Low-Power Plant No. 1 (SL-1) Accident • January 3, 1961 • 3 MW • National Reactor Testing Station, Idaho • Control Rods Manually Removed • Reached 20,000 MW in 0.01 s • Destroyed Core, Melted Fuel, Steam/Pressure Explosion • Killed the 3 Military Personnel • Need Control Rod Interlocks • Uncontrolled Reactors are Very Dangerous

  4. Millstone 1 Accident • September 1, 1972 • 660 MWe BWR • Malfunction if Water Purification Systems • Seawater Corrosion to Primary Coolant Loop • Repaired and Resumed Operation • No Injuries or Radiation Release • Need Alternative Cooling Methods

  5. Browns Ferry 1 and 2 Fire • March 22, 1975 • Three 1095 MWe BWRs, Alabama • Worker Performing Leak Tests with a Candle Started a Fire in the Walls • 7 Hours, $10M & 1 year Repair • Burned ~2000 Cables • Alternative Cooling Methods Needed for Core • No Serious Injury or Radiation Release • Segregation of Components and Wiring for Safety and Control

  6. Ginna Incident • January 25, 1982 • 490 MWe PWR, New York State • Loose Metal Object Vibrated and Damaged Steam Generator Tubes • Delayed Coolant Response • Release of Some Radiation (Noble Gases) • No Injuries

  7. Mihama-2 Incident • February 9, 1991 • 500 MWe PWR, Japan • Steam Generator Tube Rupture • Fatigue Failure • Corrosion Debris • Improper Installation of Antivibration Support • Small Release of Radioactive Gas • No Injuries

  8. NRX Incident • December 12, 1952 • 40 MWt CANDU, Chalk River, Canada • Operator Removed Too Many Control Rods • Supervisor Had Them Returned but They Didn’t Complete Enter the Core • Power Rose to 60 – 90 MWt • Low Coolant Flow for Testing • Core Melted and Ruptured • 10,000 Ci Fission Products Dumped in 1M Gallons Water • Need Proper Control Rod Operations

  9. Lucens Incident • January 21, 1969 • 30 MWt, Lucens, Switzerland • Combined Magnox and Heavy Water Reactor • Corrosion of Fuel Rod = Rupture • Molten Cladding Blocked Coolant • Pressure Burst • Need Better Understanding of Chemical Interactions, Reactor Characteristics, and Monitoring

  10. Windscale Fire • October 7-10, 1957 • Plutonium Production • Heating to Anneal Graphite Moderator Defects • Fuel Overheated • Released 20,000 Ci I-131 and Noble Gases • Milk Production Stopped for 6 weeks • Estimated Increase of 30 Cancer Deaths for Every 1M Cancer Deaths • Filter Trapped Some of the Release

  11. St. Laurent Fuel Meltdown • October 17, 1969 • 500 MWt, MagnoxSt. Laurent, France • Improper FuelLoading, Charging Machine Override • Blocked Coolant Channel • Molten Fuel • No Radiation Release Beyond Core • No Injuries • 1 year to Cleanup and Modify the Reactor • Heat Removal is Critical

  12. Hunterston B Seawater Problem • October 11, 1977 • AGR, Hunterston, Scotland • Temporary Testing with Pure Water • CO2 Acidified Water to Cause Corrosion • 8000 L Seawater Entered Reactor Vessel • Repairs Cost £13M and 28 months • Temporary Modifications Should be Properly Analyzed

  13. Hinkley Point B Fuel Damage • November 19, 1978 • AGR • Fuel Loading During Reactor Operation • Vibrations and Pressure Increased Cladding Cracks • Fuel and Heat Removal Failure During Operation • On-Load Refueling Performed at Low Power

  14. Experimental Breeder Reactor I (EBR-1) Meltdown Accident • Novemeber 29, 1955 • First Reactor to Generate Electricity • High Temperature Effects Caused Fuel Pins to Bow Closer Together and Increase Reactivity • Melted 40% of the Core • Fast Reactors Built to Expand Rather than Contract

  15. Enrico Fermi Fuel Melting Incident • October 5, 1966 • 200 MWt LMFBR, Lagoona Beach, Michigan • Guide Plate became Loose and Blocked 2 Fuel Channels • Fuel Melted • No Injury or Outside Release of Radiation • 10,000 Ci Fission Products Released to Sodium Coolant • Need Careful Analysis of Parts in a Reactor

  16. Examples and Problems 5.1 • Decay Heat Removal using PORVs • How Many PORVs are Needed to Release Decay Energy from a 4000 MWt PWR in 100 seconds after Shutdown? • Valve Area = 0.002 m2 • Decay Heat Fraction is 3.2% of Power (Table 2.2) • Maximum Release Rate is 17,000 MW/m2 (Section 4.3.2) • Decay Heat Rate is 128 MW • Flow Area Required = 0.0075 m2 • Therefore, 4 PORVs Would be Required

  17. Examples and Problems 5.1 • Other Problems using Same Equations • Evaluate the Problem for Different Lengths of Time, Operational Power Levels, Flow Areas, or Number of PORVs • Additional Analysis • If 1 PORV Valve Remained Closed, How Long Would it Take to Remove the Decay Heat? • Re-evaluate the Problem if the Efficiency of Energy Release for Each PORV is Reduced

  18. Examples and Problems 5.2 • Evaporation of Coolant • A 3800 MWt PWR is half uncovered due to a small LOCA event; what is the rate of becoming uncovered at 1 h after shutdown? • Void fraction = 0.5 • Fuel occupies 40% of core • Core diameter, d = 3.6 m • Core length, l = 5 m • Pressure, P = 85 bars • Assume uniform heat flux across core

  19. Examples and Problems 5.2 • (V/l)core = (pr2)*(1-0.5)*(1-0.4) = 3.054 m2 • Using Table 2.2 (Heat from core = 1.4%) • 3800 MW * 1.4% * ½ core = 2.66 x 107 W • Latent heat of evaporation at 85 bars • 1.4 x 106 J/kg • Evaporation rate = 26.6/1.4 = 19 kg/s • Density of water at 85 bars • 713 kg/m3

  20. Examples and Problems 5.2 • Volume evaporation rate = 0.0266 m3/s • Uncovery rate • Volume evap rate / volume of core per length • U = 31.4 m/h

  21. Examples and Problems 5.2 • Other Problems using Same Equations • What if heat generation isn’t uniform across the core? • How and why would the evaporation rate change with fluid level in the core? • Additional Analysis • What if the heat generation changed across the cross-sectional area of the core as well?