1 / 24

Orionplus: Compact, Durable, Ingenious Gas Detector with Extra Bright LEDs

The Orionplus gas detector is a compact and durable device designed for easy, one-hand operation. With its extra bright LEDs and high contrast gas measurement display, it offers clear visibility in any environment. It is available in a 5-gas configuration based on ORION sensors, with options for CO2, Combustible, CO, O2, and H2S measurements. The Orionplus is also available with a pump and data logging capabilities. Its user-friendly features include a graphical display, easy calibration, and password-protected setup. With its robust construction and innovative design, the Orionplus is the ideal gas detector for various industries.

bernad
Télécharger la présentation

Orionplus: Compact, Durable, Ingenious Gas Detector with Extra Bright LEDs

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. [Compact. Durable. Ingenious.]

  2. [ Why Orionplus? ] Extra bright, highly visible LEDs Extremely robustconstruction Separate Info display High contrast, large gas measurementdisplay Fits comfortablyin the hand Simple “real” one hand operation

  3. [ What is it? ] 5 gas detector based on ORION ►IR CO2/Comb/CO/O2/H2S ►Or any combination Available only with pump Available only with data logging

  4. Pumped version only IR-Sensor Graphical Display Data logging standard Permacheck™ Improved Horn 3 Button Operation Easy singlechannel calibration Password Protected Setup [ What’s different? ]

  5. [ Where to sell ] Aboard Ship • CO/CO2/O2/Comb Tunneling • CO/CO2/O2/Comb Municipal • CO/CO2/O2/Comb/H2S Breweries/ Soft drinks/Food processing Anywhere CO2 is generated • CO2 is toxic!!

  6. [Effects of CO2 ] Effects of CO2 40.000-60.000 ppm 60.000-80.000 ppm 80.000-100.000 ppm 200.000 ppm 5000 ppm Headaches, dizziness, blood pressure change inveins and brain Paralyzing as if curare has been used Extinguishing of a burning candle, spasm, fast unconsciousness, death Deadly within a few seconds TWA Value 4-6% Vol% 6-8 Vol% 8-10 Vol% 20 Vol% 0.5 Vol%

  7. CO2 is heavier than Oxygen TWA value = 5000 ppm (0.5% Vol) 0.5% CO2 = 0.1% O2 displacement O2 Alarm = 19.5% 19.5% O2 > 8% CO2 (80,000 ppm) Answer is: NO!! [ Measuring CO2 by O2 displacement? ]

  8. 20,83 20,53 19,33 20,93 0,5 2,0 8,0 0,03 [CO2 in Relation to O2? ] 25 - 20 - 15 - 10 - 5 - 0 - 19.5% Vol% O2 Vol% Carbon Dioxide

  9. [ Features - User ] Big display – great contrast User friendly software and firmware Robust design Well balanced in the hand

  10. Autocal – all 5 Sensors in about 3 minutes• 1 bottle, all 5 gases Modular design – easy to maintain Low “Cost of Ownership” Economical price performance ratio [ Features - Financial ]

  11. [ Features – Ease of Use] Easy and user friendly3 button operation Setup mode passwordprotected All settings in clear text andicons with “online - help”

  12. [ Pump ] Only pumped version available►Proven reliability PulseCheck replaced by ‘PermaCheck™’ ►Permanent pump control Existing Orion accessories will fit ►Probe, filters, etc.

  13. 100 % Compatible with ORION [ Accessories ] Leather and rubber boot Sampling line and probes Charger Calibration gas ►5 gas mix

  14. [ How Does IR Detection Work ] Absorption of IR Light by the C-H bonds (‘hydro carbons’) of molecules Mirror doubles path length but can get condensed with temp. changes Condensation will absorb some of the light and will cause ‘false readings’ MSA IR sensor Does Not Use a mirror The lamp and detector are placed in one line IR Lamp Typical portable IR sensor Mirror Detector

  15. [ IR-Sensor ] No mirror IR lamp and detector in line No mirror = no more lost signal Fail Safe!

  16. [ Display ] All information at a glance Clearly structured Homogeneous back light

  17. [ Display-start ] Serial Number Firmware version Company –user changeable Unit Number – user changeable Department Name – user changeable

  18. [ Display ] Time/Date Battery power Confidence dotcircle around as longas everything works well Calibrationstandard options Measured values

  19. [ Display – Setup mode ] Password needed to enter Setup mode Pass Code:info – on/off – reset– on/off – info button Password forgotten?Set your own with the ORIONplus Link Software

  20. [ Display – Calibration ] Choose Calibration Info display always shows where you are – in text and pictogram Main display shows what you are going to do And if necessary, what you need

  21. [ Display – Calibration ] Info display always shows you where you are – in text and pictogram Preset 5 in one gas values Abort brings you back to calibration selection Next will startthe calibration

  22. [ Display – Calibration FAS ] The Zero calibration – Fresh Air – will run automatically (90 s) Main display shows calibration values Displays calibration or current value Abort brings you back to calibration selection Value will display current value

  23. [ Display – Calibration Span ] The Span calibration will run automatically (90 s) Main display shows calibration values Displays calibration or current value Abort brings you back to calibration selection Gas will displaygas label

  24. Great IR Sensor Competitive Pricing •No mirror = nocondensation •Drager Multiwarn •ISC ATX620 Proven Reliability Made by MSA •Orion sensors, pumpbattery and case [ Why Orionplus? ]