The effects of passive heating and cooling on the energy performance of buildings CEN - calculation - procedures Ann

slide 2. Outline. The EU CENSE projectGeneral aspects ofPassive heating Passive coolingStructural MeasuresConsideration of passive heating and cooling in the calculation of the CEN-standard EN ISO 13790Calculation of heat transferCalculation of solar heat gainsUnconditioned sunspacesOpaqu

bette
Télécharger la présentation

The effects of passive heating and cooling on the energy performance of buildings CEN - calculation - procedures Ann

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


    1. The effects of passive heating and cooling on the energy performance of buildings – CEN - calculation - procedures Anna Staudt and Hans Erhorn anna.staudt@ibp.fraunhofer.de, hans.erhorn@ibp.fraunhofer.de Fraunhofer Institute for Building Physics, Germany CENSE

    2. slide 2 Outline The EU CENSE project General aspects of Passive heating Passive cooling Structural Measures Consideration of passive heating and cooling in the calculation of the CEN-standard EN ISO 13790 Calculation of heat transfer Calculation of solar heat gains Unconditioned sunspaces Opaque elements with transparent insulation This is the presentation‘s outline: Starting with a short description of the CENSE project Followed by introducing passive heating and cooling in general As well as structural measures important therefor Finally the consideration of passive systems in the European Standardisation will be explained This is the presentation‘s outline: Starting with a short description of the CENSE project Followed by introducing passive heating and cooling in general As well as structural measures important therefor Finally the consideration of passive systems in the European Standardisation will be explained

    3. slide 3 The EU CENSE project (Oct. 2007 - March 2010) Aim of the project: To accelerate adoption and improved effectiveness of the EPBD related CEN- standards in the EU Member States These standards were successively published in the years 2007-2008 and are being implemented or planned to be implemented in many EU Member States. However, the full implementation is not a trivial task Main project activities: To widely communicate role, status and content of these standards; to provide guidance on the implementation To collect comments and good practice examples from Member States aiming to remove obstacles To prepare recommendations to CEN for a “second generation” of standards on the integrated energy performance of buildings

    4. slide 4 Brief introduction A brief introduction to the CENSE project and the CEN-EPBD standards is provided in a separate presentation: