What is MPPT and why it is needed? (Maximum power point tracking) It is needed a controller (MPPT) to achieve the highest efficiency and provide a stable power under the intermittent weather condition Why IC technique ? It shows good performance under the intermittent of solar irradiance

Télécharger la présentation

What is MPPT and why it is needed? (Maximum power point tracking)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. What is MPPT and why it is needed? (Maximum power point tracking) It is needed a controller (MPPT) to achieve the highest efficiency and provide a stable power under the intermittent weather condition • Why IC technique ? It shows good performance under the intermittent of solar irradiance The simulation result will show how good is the performance of this IC technique.

  2. PV Model • A solar cell basically is a p-n semiconductor junction. When exposed to light, a dc current is generated.

  3. PV Characteristic

  4. IC MPPT Technique • The incremental conductance method is developed under the fact of slope of the PV array power curve is zero at the MPP IC MPPT Algorithm

  5. Block Diagram of the Proposed PV System

  6. SIMULATION SYSTEM

  7. Under mask the system

  8. Simulation under constant solar irradiance • The maximum standard operating for constant solar irradiance is assumed to be 1000 W/m2 in the study. (A) The measured output of PV Module (B) The respond of IC MPPT tracking algorithm

  9. Output from boost converter Under 1000 W/m2 of solar irradiance, The duty cycle for boost converter is a constant value 0.45 and the booster convert around 92kW of power with constant ouput voltage 500 V to the PV inverter.

  10. Comparison of the measured output of PV module with output of boost converter The PV module provides 100kW and the boost converter convert 92kW of energy

  11. Simulation under decreasing solar irradiance The figure shows the decreasing solar irradiance (1000 W/m2- 800 W/m2 -250 W/m2). (A) Decreasing of solar irradiance(B) Duty cycle of boost converter

  12. (A) The measured output of PV Module (B) The respond of IC MPPT tracking algorithm

  13. Output from boost converter The figure shows the power, voltage, current of boost converter. Under (1000 W/m2- 800 W/m2 -250 W/m2) of solar irradiance, the booster convert around 92kW - 80 kW - 25 kW of power. The booster maintains the output of voltage to be 500 V to the PV inverter.

  14. Comparison of the measured output of PV module with output of boost converter The PV module provides 100kW (1000 W/m2) 80kW (800W/m2) 25kW (250 W/m2) and the boost converter convert 92kW, 74kW, 20 kW

  15. Simulation under different solar irradiance The figure A shows the variations of solar irradiance (600 W/m2- 800 W/m2 - 400 W/m2 -600 W/m2) Figure B shows the duty cycle of boost converter responding to different solar irradiance. In fact, an extreme variation of solar irradiance occur rarely.

  16. (A) The measured output of PV Module (B) The respond of IC MPPT tracking algorithm

  17. Output from boost converter The figure shows the measurement output from boost converter. The figure shows the power, voltage, current of boost converter. Under (600 W/m2- 800 W/m2 - 400 W/m2 -600 W/m2) of solar irradiance, the booster maintains output voltage to be 500 V constantly.

  18. Comparison of the measured output of PV module with output of boost converter The power efficiency is approximately 90%. The simulation result shows the MPPT works and respond fast and well even in any behavior of solar irradiance and also gain a high efficiency

  19. PV module connected to grid The simulation is under 1000 W/m2 of solar irradiance. Output voltage of PV Inverter Output voltage of load

  20. The figure shows the voltage after connected to the grid. to phase A-B in 25 kV voltage level. Output voltage of grid