1 / 17

Prof. D. R. Wilton

ECE 3317. Prof. D. R. Wilton. Notes 10 Transmission Lines (Impedance Matching). [Chapter 6]. Smith Chart. S. Z g. Z 0. sinusoidal source. Z L. z = 0. z.

cais
Télécharger la présentation

Prof. D. R. Wilton

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ECE 3317 Prof. D. R. Wilton Notes 10 Transmission Lines(Impedance Matching) [Chapter 6]

  2. Smith Chart S Zg Z0 sinusoidal source ZL z = 0 z Impedance matching is very important to avoid reflected power (loss of efficiency), presence of standing waves (SWR), and strong frequency dependences. • We will discuss two methods: • Quarter-wave transformer • Single-stub matching

  3. Quarter-Wave Transformer Z0 Z0T ZL = RL Zin Quarter-Wave Transformer: First consider a real load. Hence

  4. Quarter-Wave Transformer (cont.) Z0 Z0T ZL = RL Zin Set Hence This yields Thus the tranformer section characteristic impedance is the “geometric mean” of the line and load impedances.

  5. Quarter-Wave Transformer (cont.) Z0 Z0T YL = 1 / ZL Next, consider a general (complex) load impedance ZL. shunt (parallel) susceptance New model: Z0 Z0T

  6. Quarter-Wave Transformer (cont.) Z0 Z0T YL = GL + j BL Ys = jBs Summary of quarter-wave transformer matching method

  7. Quarter-Wave Transformer (cont.) Z0 Z0T YL = GL + j BL Bs = - BL Z0s ls Realization using a shorted stub (An open-circuited stub could also be used.)

  8. Single-Stub Matching A susceptance is added at a distance d from the load. d ZL Y0 = 1 / Z0 1) We choose the distance d so that at this distance from the load (i.e., Gin = Y0) 2) We then choose the shunt susceptance so that

  9. Single-Stub Matching (cont.) d ZL Y0 = 1 / Z0 The feeding transmission line on the left sees a perfect match.

  10. Single-Stub Matching (cont.) d Z0 ZL Z0s ls Realization using a shorted stub (An open-circuited stub could also be used.)

  11. Single-Stub Matching (cont.) d Z0 ZL Z0s ls We use the Smith chart as an admittance calculator to determine the distance d. • Convert the load impedance to a load admittance YL. • Determine the distance d to make the normalized input conductance equal to 1.0. • If desired, we can also use the Smith chart to find the stub length.

  12. Single-Stub Matching (cont.) d Z0 ZL Z0s ls Example

  13. Single-Stub Matching (cont.) use this one X X X X Smith chart scale: wavelengths toward load wavelengths toward generator

  14. Single-Stub Matching (cont.) 1.62 UNMATCHED 1.55 1.0 ZL 0.78 0.38 z z X Crank diagram

  15. Single-Stub Matching (cont.) 1.62 UNMATCHED 1.55 1.0 ZL 0.78 0.38 SWR = 4.26 z z MATCHED 1.62 1.55 ZL jBs SWR = 1.0 0.78 z z

  16. Single-Stub Matching (cont.) Next, we find the length of the short-circuited stub: Rotate clockwise from S/C to desired Bs value. Assume Z0s = Z0 Otherwise, we have to first denormalize to the line impedance, then renormalize to stub characteristic impedance! 0+j1 0+j2 0+j0.5 0+j0 0-j0.5 0-j2 0-j1 admittance chart

  17. Single-Stub Matching (cont.) admittance chart From the Smith chart: Analytically: X