1 / 30

SUTS Data taking and processing with Monitoring

Explore the powerful scanning and data flow capabilities of S-UTS, including high-speed data taking, real-time processing, and data reduction for analysis. Monitor and check data quality online during scanning to ensure efficiency and accuracy.

candidaa
Télécharger la présentation

SUTS Data taking and processing with Monitoring

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. SUTS Data taking and processing with Monitoring K. Morishima Flab Nagoya Univ. OPERA Emulsion Workshop 2008/01/22-23

  2. OPERA film OPERA film OPERA film OPERA film OPERA film S-UTS Scan and Data Flow Scanning Power is Very Powerful ! ・High Speed Data Taking -> Large Area and Long Time -> Real Time Processing ・Huge Data Size -> Data Reduction S-UTS Reconstructed Data for Analysis MicroTrack segment Pipeline processing 55 cm^2 / hour / stage online monitor checking raw data during data taking

  3. OPERA film OPERA film OPERA film OPERA film OPERA film S-UTS Scan and Data Flow Scanning Power is Very Powerful ! ・High Speed Data Taking -> Large Area and Long Time -> Real Time Processing ・Huge Data Size -> Data Reduction S-UTS Reconstructed Data for Analysis MicroTrack segment Pipeline processing 55 cm^2 / hour / stage online monitor checking raw data during data taking

  4. Online Scanning Data Quality Check checked Items during scanning ・ number of tracks ・ surface recognition ・ track over flow (over SUTS processing power) →Keeping Efficiency of Scanning Area is over 99% (higher than track finding efficiency) ERROR → Mail to shifter → retry scanning

  5. Scanning Result- Quality Sheet on the Online Monitor-

  6. Surface Recognition Error Online Monitor Viewer Feedback during scan , and retry Film Size Prediction Area (mm)

  7. SUTS data taking quality Dead area ratio # of Plate 1% PEANUT Brick

  8. OPERA film OPERA film OPERA film OPERA film OPERA film S-UTS Scan and Data Flow Scanning Power is Very Powerful ! ・High Speed Data Taking -> Large Area and Long Time -> Real Time Processing ・Huge Data Size -> Data Reduction S-UTS Reconstructed Data for Analysis MicroTrack segment Pipeline processing 55 cm^2 / hour / stage online monitor checking data during data taking

  9. OPERA film OPERA film OPERA film OPERA film OPERA film S-UTS Scan and Data Flow Scanning Power is Very Powerful ! ・High Speed Data Taking -> Large Area and Long Time -> Real Time Processing ・Huge Data Size -> Data Reduction S-UTS Reconstructed Data for Analysis MicroTrack segment Pipeline processing 55 cm^2 / hour / stage online monitor checking data during data taking

  10. Data Process Scheme Data Process during data taking SUTS datataking pl01 pl02 pl03 pl04 pl05 pl06 S-UTS scan time Correct Emulsion Distortion Build BaseTrack Correct Global Displacement and Local Deformation Build Linklet ( 0 skip ) Build Linklet ( 1 skip ) Build Linklet ( 2 skip ) Build Chain All processes are going with monitoring these qualities

  11. Data Process Scheme Data Process during data taking SUTS datataking pl01 pl02 pl03 pl04 pl05 pl06 S-UTS scan time Correct Emulsion Distortion Build BaseTrack Correct Global Displacement and Local Deformation Build Linklet ( 0 skip ) Ex. PEANUT Brick Full Area Scan scanning time : 10days process time : 3 – 4 days Build Linklet ( 1 skip ) Build Linklet ( 2 skip ) Build Chain All processes are going with monitoring these qualities

  12. Data Structure and Stream PL01 PL02 PL03 PL04 Micro track Micro track Micro track Micro track Correction Parameter Correction Parameter Correction Parameter Correction Parameter correct connect correct connect Base track Base track correct connect linklet chain select Data for Analysis

  13. Data Structure and Stream PL01 PL02 PL03 PL04 X,Y,Z,AX,AY,PH Micro track Micro track Micro track Micro track One parameter each microscopic view Correction Parameter Correction Parameter Correction Parameter Correction Parameter correct connect correct connect Base track Base track correct connect linklet chain select Data for Analysis

  14. Data Structure and Stream PL01 PL02 PL03 PL04 Micro track Micro track Micro track Micro track Correction Parameter Correction Parameter Correction Parameter Correction Parameter correct correct connect Base track Base track correct connect linklet chain select Data for Analysis

  15. Measure Emulsion Distortion One of quality check files ・Significance ・Continuity ・Interpolate 90mm ・position ・angle ・gap ・rotation 50mrad 115mm Vector : difference between microtrack angle and basetrack angle

  16. Data Structure and Stream PL01 PL02 PL03 PL04 Micro track Micro track Micro track Micro track Correction Parameter Correction Parameter Correction Parameter Correction Parameter save parameters correct correct connect Base track Base track correct connect linklet chain select Data for Analysis

  17. Data Structure and Stream PL01 PL02 PL03 PL04 Micro track Micro track Micro track Micro track Correction Parameter Correction Parameter Correction Parameter Correction Parameter connect correct connect Base track Base track correct connect linklet chain select Data for Analysis

  18. BaseTrack Connect MicroTrack segments One of quality check files Ph distribution Angle difference Number of tracks angle distribution Position distribution ・Background = Fake BaseTrack

  19. Data Structure and Stream PL01 PL02 PL03 PL04 Micro track Micro track Micro track Micro track Correction Parameter Correction Parameter Correction Parameter Correction Parameter connect connect Base track Base track correct linklet chain select Data for Analysis

  20. Local Deformation position ・Significance ・Continuity ・Interpolate 90mm ・position ・angle ・gap ・rotation 50 micron 115mm

  21. Local Deformation angle ・Significance ・Continuity ・Interpolate 90mm ・position ・angle ・gap ・rotation 50mrad 115mm

  22. Data Structure and Stream PL01 PL02 PL03 PL04 Micro track Micro track Micro track Micro track Correction Parameter Correction Parameter Correction Parameter Correction Parameter connect connect save parameters Base track Base track correct linklet chain select Data for Analysis

  23. Data Structure and Stream PL01 PL02 PL03 PL04 Micro track Micro track Micro track Micro track Correction Parameter Correction Parameter Correction Parameter Correction Parameter connect connect Base track Base track connect linklet chain select Data for Analysis Linklet : information of connection between tracks

  24. Linklet Connect track segments One of output quality files 0 skip position difference Angle difference density distribution in Process unit position distribution angle distribution

  25. Data Structure and Stream PL01 PL02 PL03 PL04 Micro track Micro track Micro track Micro track Correction Parameter Correction Parameter Correction Parameter Correction Parameter correct connect correct connect Base track Base track correct connect linklet chain select Data for Analysis

  26. Linklet : connection between 2 track segments ( ex. BaseTracks ) • Measurement errors • Minimum momentum of tracks to be connected • Chain : reconstructed tracks using Linklets pl05 pl04 linklets Pl03 pl02 pl01

  27. Data Structure and Stream PL01 PL02 PL03 PL04 Micro track Micro track Micro track Micro track Correction Parameter Correction Parameter Correction Parameter Correction Parameter connect connect Base track Base track connect linklet chain Select Data for Analysis

  28. Data Size 500 GByte 1 GByte Data Structure and Stream PL01 PL02 PL03 PL04 Micro track Micro track Micro track Micro track Correction Parameter Correction Parameter Correction Parameter Correction Parameter connect connect Base track Base track connect linklet Ex. PEANUT Brick Full Area Scan chain Select Data for Analysis

  29. Reconstructed Data for Analysis % Created by ecfsal: Version 2.4 % on 2007/03/09 23:28:09 +09:00 (JST) 0 0 2 0 0.0 0.0000 4 11 21 31 41 320 5 11 51 11 16423 19736 150025 0.3900 -0.0238 11775.7 11243.6 -245 21 18833 23125 190068 0.3909 -0.0243 11663.9 11252.4 -535 31 34118 48222 220080 0.3938 -0.0194 11555.1 11258.4 -825 41 26151 39167 140027 0.3945 -0.0250 11445.2 11262.6 -1115 51 7435 7136 180062 0.3824 -0.0355 11335.5 11269.4 -1405 432 2 11 21 11 456 243 180057 0.0924 0.1777 5617.0 5624.1 -245 21 407 213 180058 0.0790 0.1511 5592.5 5579.7 -535 Event header Chain header Track segments belonging a chain

  30. SUTS Scanning Log full area scan of 500 OPERA films Black : SUTS01 Blue : SUTS02 Red : SUTS03 2008/01/21 2007/05/15