1 / 13

5 reasons why SITRANS F C MASSFLO Flowmeters are among the best selling flowmeters today

Advanced technology for increased accuracy and profitability in the Value Chain. A complete line Siemens offers a complete line of highly accurate, coriolis mass flow meters for a multitude of industries and critical process applications.

caulfield
Télécharger la présentation

5 reasons why SITRANS F C MASSFLO Flowmeters are among the best selling flowmeters today

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Advanced technology for increased accuracy and profitability in the Value Chain A complete lineSiemens offers a complete line of highly accurate, coriolis mass flow meters for a multitude of industries and critical process applications. Thanks to their accuracy they deliver precise information about fluids or gas passing through a pipe for dosing, product blending, determining billing or cost and many other applications. Dedicated Program SITRANS F C • 5 reasons why SITRANS F C MASSFLO Flowmeters are among the best selling flowmeters today • High accuracy – 0.10% of mass – and repeatability ensure maximum quality and reduced waste • Multi-parameter measurement for mass flow rate, volumetric flow rate, density, fraction flow and temperature • Measurements unaffected by changes in pressure or temperature • Each flowmeter is factory calibrated before shipment • Maintenance free: no moving parts

  2. Dedicated ProgramSITRANS F C MASSFLO flow meters • Siemens offers a comprehensive selection of flow meters for the industry • Chemical • Petro-chemical • Food & beverage • Pharmaceutical • Automotive • Refining • Power & utility Dedicated Program SITRANS F C

  3. MASS 600019” wall mount MASS 6000 Exd MASS 600019” MASS 6000IP 67/NEMA 6 SIFLOW FC070 • Communication modules: • HART • Profibus PA/DP • Devicenet • Modbus RTU MASS 2100 DI 1.5 FC300 DN 4 MASS 2100DI 3 – DI 40 MC 1DN 50 – DN 150 One Platform. Infinite solutions Dedicated Program SITRANS F C • Greater flexibility • Compact or remote • One type transmitter for all sizes • Industry specific sensors and transmitters • Flexible logistics handling • Quick reaction to changing customer demands – even after ordering - delivery

  4. MASS 6000 Enhanced Signal processing MASS 6000 With MASS 6000 – Enhanced signal processing transmitters, Siemens pushes development of the coriolis technology a giant leap forward. Our technology is unaffected by variations in pressure, temperature, density, electrical conductivity and viscosity. Transmitters SITRANS F C Dedicated mass flow chip with the latest ASIC technology improves step-response and enables high-speed batching

  5. Innovative features with MASS 6000 lgal l/sgal/sec lgal kg/s lbs/sec Mass flow, volume flow, density, temperature and fraction flow are all standard measurements kg lbs Transmitters SITRANS F C kg/m3 lbs/ft3 °C °F • Superior noise immunity due to a patented DFT (Discrete Fourier Transformation) algorithm • Improved dynamic measurement range. Application flexibility is greatly enhanced, since the meter can be locked at any point in the installation • Advanced diagnosis and service menu enhances trouble shooting and meter verification

  6. 1 3 4 2 5 EXceptional safety and performance 1. Fully stainless steel enclosure, ensuring optimum cost of ownership 2. Intrinsically safe keypad and display offer optimum functionality and programming in hazardous areas 3. Add-On Modules can be retrofitted to existing flow meters, providing communications and other functions to meet current and future demands 4. SENSORPROM technology facilitates; Factory pre- programming of calibration data. All values and settings made by the user are automatically stored 5. All Siemens sensor constructions are intrinsically safe to Ex IIC, meeting industry’s toughest challenges MASSFLO EX Design For maximum safety and peace of mind • In our commitment to the chemical industry, • Siemens offers industry specific solutions to • help you • improve asset utilization • improve quality-based performance • strengthen safety • reduce cost of ownership Transmitters SITRANS F C

  7. SIFLOW FC070 – As easy to install as playing a CD • SIFLOW FC070 is a true multi-parameter coriolis mass flow transmitter suitable for all flow applications and industries, ready for quick installation – both physically and in system integration – compact and space-saving. • Namur NE21 and VDE2560 • CE, cULus • Standard version: ATEX II 3 G EEx nA II T4 • Ex version: ATEX II (1) G [EEx iA] IIC Transmitters SITRANS F C Standard version available in ultra compact 40 mm S7-300 enclosure Ex version available in compact 80 mm S7-300 enclosure

  8. Complete Range of SITRANS F C transmitters Transmitters SITRANS F C * * MASS 6000 Exd only available with Profibus PA and HART MASS 6000 19” Wall mounted MASS 6000 19” MASS 6000 IP 67/NEMA 6 MASS 6000 Exd SIFLOW FC070 Seamless integration into SIMATIC

  9. Fit back plate to converter and measurement can commence Mount the clamp Fit the meter in the clamp and tighten Connect pre-wired multi-plug connector High accuracy in compact design FC300 DN 4 / 1/6‘‘ • Siemens has created the most compact coriolis flow meter in its class. The size and weight makes it easy to install and integrate demanding applications like e.g.: • Fuel injection nozzle testing • Refrigerant charging for hermetic compressors • Dosing of flavorings and additives • Measurement of essence and fragrances in the cosmetics industry • High accuracy gas measurement – N2, O2, Ar, H2, ethylene • Gasoline & diesel test rigs Sensors SITRANS F C Size: 135x205x58 mm Weight: 3.5 kg

  10. 4 1 2 3 Meeting industry‘s toughest challenges High immunity against changing process conditions and vibrations is achieved with unique center block concept Only one pipe, with no welds. Ideal for CIP applications Safe pipe design. We use the market’s thickest pipe and offer a choice of high grade stainless steel or Hastelloy for corrosive applications All Siemens sensor constructions are intrinsically safe to Ex ia IIC (Zone 0), meeting industry’s toughest challenge MASS 2100 DI 3 – DI 40 / 1/16‘‘ – 2‘‘ • Optimum meter performance is achieved through an intelligent sensor design • High accuracy 0.1% of rate with a large turndown ratio • Self draining in horizontal installation • Minimum pressure loss due to a large internal diameter throughout the entire meter Sensors SITRANS F C

  11. 1 3 2 4 Mount the clamp Fit the meter in the clamp and tighten Connect the pre-wired multi-plug connector Fit backplate to converter and measurement can commence Serious performance delivers reliable results 1. The meter is installed with a single quick release clamp fitting and a single multi- plug connector that is fast and cost effective. 2. Maximum immunity to noise. The centre block concept, to- gether with balanced pipe loops, ensure dependable long-term stability eliminating influences from process conditions 3. Plug & Play. Install and commission a meter in less than 10 minutes 4. Single-pipe design optimizes hygiene and safety. All our sensors consist of one single pipe without any welds ensuring that steam or CIP cleaning can be carried out with confidence MASS 2100 DI 1.5 / 11/16‘‘ In many industries, accurate recipe control means everything. The MASS 2100 1.5 has demonstrated superior performance. It is the preferred meter for research and development and mini-plant applications for liquid or gas measurement, when measuring small quantities is important Sensors SITRANS F C

  12. Meeting industry‘s toughest challenges MC1 DN 40 – DN 150 / 2‘‘ – 6‘‘ • Space saving sturdy design • Insensitive to pipeline stresses and vibrations • Self draining in both horizontal and vertical positions • Rigid, solid mounting structure • Optimally oriented inductive sensors generate large signal amplitudes • Parallel S-tube design enhances accuracy and turndown ratio Sensors SITRANS F C In the large size category, the MC1 offers the ideal fit between size, maximum flow capacity and ease of installation

  13. Complete Range of SITRANS F C sensors Sensors SITRANS F C MASS 2100 DI 1.5 FC300 DN 4 MASS 2100 DI 3 – DI 40 MASS 2100 DN 50 – DN 150