RinNOVA & Inovia CIRCUITI IDRAULICI

RinNOVA & Inovia CIRCUITI IDRAULICI. SCHEMA IDRAULICO – VERSIONE MISTA. Tre vie in riscaldamento. Tre vie in sanitario. CIRCUITO IDRAULICO. CIRCOLATORE COMPITO IN RISCALDAMENTO FAR CIRCOLARE L’ACQUA NELL’IMPIANTO TERMICO IN SANITARIO FAR CIRCOLARE L’ACQUA NELLO SCAMBIATORE SANITARIO

chase
Télécharger la présentation

RinNOVA & Inovia CIRCUITI IDRAULICI

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. RinNOVA&InoviaCIRCUITI IDRAULICI

  2. SCHEMA IDRAULICO – VERSIONE MISTA Tre vie in riscaldamento Tre vie in sanitario

  3. CIRCUITO IDRAULICO • CIRCOLATORE • COMPITO • IN RISCALDAMENTO FAR CIRCOLARE L’ACQUA NELL’IMPIANTO TERMICO • IN SANITARIO FAR CIRCOLARE L’ACQUA NELLO SCAMBIATORE SANITARIO • CARATTERISTICHE • COMPATTO • DISAREATORE INCORPORATO • DATI • 2 MODELLI • PER 24/28KW:WILO INTNFSL12/Premium • PER 32KW : WILO INTNFSL12/5 • ALIMENTATO A 230 Vc.a. • POTENZA: • 59W x 24-28KW • 77W x 32KW

  4. VASO D’ESPANSIONE • COMPITO • COMPENSA L’AUMENTO DI PRESSIONE DETERMINATO DALL’AUMENTO DI TEMPERATURADELL’ACQUA NELL’IMPIANTO DI RISCALDAMENTO • DATI • CAPACITA’ TOTALE 7 LITRI • PRESSIONE DI PRECARICA 1 bar • CONTENUTO MASSIMO D’ACQUA NELL’IMPIANTO 109 LITRI

  5. CIRCUITO IDRAULICO SCAMBIATORE PRIMARIO • COMPITO • TRASFERIRE IL CALORE DELLA COMBUSTIONE ALL’ACQUA CHE LO ATTRAVERSA • CARATTERISTICHE • INTERAMENTE IN RAME • RISPETTO LA VERSIONE PRECEDENTE HA UN TUBO CURVO DI ENTRATA ED USCITA PER RIDURRE LE PERDITE DI CARICO. • COMPOSTO DA 8 TUBI OVALI MOLTO PIATTI(OLTRE IL 90% DI SUPERFICIE) • 4 MODELLI • 24KW x 24S da 73 alette di scambio L 301 • 24KW x 24A da 86 alette di scambio L 341 • 28KW x 28A da 94 alette di scambio L 369 • 28/32 KW x 28S e 32S da 97alette (prima erano 85) di scambio L 369 L

  6. NTC RISCALDAMENTO NTC RISCALDAMENTO E TERMOSTATO SICUREZZA SONDA DI TEMPERATURA A 4 POLI (2 NTC DISTINTI) POSTA SULL’USCITA DELLO SCAMBIATORE PRIMARIO • NTC 1: COMUNICA ALLA SCHEDA LA TEMPERATURA DI USCITA DELL’ACQUA DALLO SCAMBIATORE PRIMARIO TRADUCENDOLA IN UN SEGNALE ELETTRICO PER: • GESTIONE MODULAZIONE RISCALDAMENTO • CONTROLLO CIRCOLAZIONE CIRCUITO PRIMARIO (VERIFICA DELLA VELOCITA’ DI INCREMENTO DELLA TEMPERATURA) • NTC2: COMUNICA ALLA SCHEDA LA TEMPERATURA DI USCITA CHE BLOCCHERA’ LA CALDAIA LA LA TEMPERATURA SUPERA I 105°C (BLOCCO TERMICO E02)

  7. GRUPPO ACQUA -VERSIONE MISTA TRASDUTTORE DI PRESSIONE FLUSSIMETROSANITARIO VALVOLA 3 BAR 2° NTC SANITARIO (SU MODELLO Inovia) MOTORE VALVOLA 3 VIE RUBINETTO DI SCARICO 1° NTC SANITARIO RUBINETTO DI CARICO

  8. GRUPPO MANDATA • GRUPPO DI MANDATA • POSIZIONATO SULLA PARTE SINISTRA DELLA CALDAIA • MATERIALE COMPOSITO (BREVETTO BSG); COMPOSTO DA: • VALVOLA TRE VIE • TRASDUTTORE DI PRESSIONE • BY PASS • NTC SANITARIO • ATTACCHI IDRAULICI • MANDATA RISC. • USCITA SAN.

  9. GRUPPO MANDATA – VALVOLA TRE VIE • VALVOLA TRE VIE • IL COMPITO E’ DI DEVIARE IL FLUSSO DELL’ACQUA CHE ESCE DALLO SCAMBIATORE PRIMARIO VERSO L’IMPIANTO DI RISCALDAMENTO O VERSO LO SCAMBIATORE SANITARIO • COMPOSTA DA: • MOTORE BITRON “COMPATTO”: CORSA 10 mm • GRUPPO OTTURATORI (SENZA MOTORE POSIZIONE A RIPOSO IN RISCALDAMENTO) • COMMUTA IN RISCALDAMENTO SOLO QUANDO T.A. CHIUDE CONTATTO • FINE CORSA INTERNO PER EVITARE SOVRACCARICO DEL MOTORE • ALIMENTAZIONE 220Vac • RESISTENZA ELETTRICA MOTORE 8,30 Kohm • POSIZIONATO FRONTALMENTE • FACILITATA L’ACCESSIBILITA’ e DIMENSIONI PIU’ COMPATTE ALLO SCAMBIATORE A PIASTRE • RICAMBI • 2 OTTURATORI DIVERSI: • BI 1351109 fino a 09-12 • BI 1491101 da 10-12 DALLO SCAMBIATORE PRIMARIO ALLA MANDATA RISCALDAMENTO

  10. GRUPPO DI MANDATA – MOTORE TRE VIE • Celeste = comune • Nero = Riscaldamento • Marrone = Sanitario RISCALDAMENTO SANITARIO

  11. GRUPPO MANDATA – TRASDUTTORE TRASDUTTORE DI PRESSIONE • SENSORE ELETTRICO PER LA LETTURA DELLA PRESSIONE ACQUA NEL CIRCUITO PRIMARIO DELLA CALDAIA. • IL VALORE DI PRESSIONE VIENE TRADOTTO IN SEGNALE ELETTRICO IDENTICO PER TUTTE LE VERSIONI DI SCHEDE COMANDO ATTUALMENTE IN PRODUZIONE • POSIZIONATO NELLA PARTE FRONTALE (FACILMENTE ACCESSIBILE) • ALIMENTAZIONE ELETTRICA 5 Vdc • CON P< 0,35 Bar: ANOMALIA SPECIFICA SU DISPLAY(E04)

  12. EVOLUZIONE SICUREZZE IDRAULICHE • PRESSOSTATO DIFFERENZIALE • COMPONENTE DI SICUREZZA ATTIVA (se il suo contatto è aperto il bruciatore non si accende) • VERIFICA PRESENZA E CIRCOLAZIONE ACQUA NEL CIRCUITO PRIMARIO • GRUPPO IDRAULICO OTTONE + MEMBRANA + MICRO A 2 FILI • UTILIZZATO SU CALDAIE FUORI PRODUZIONE • PRESSOSTATO DI MINIMA • COMPONENTE DI SICUREZZA ATTIVA (se il suo contatto è aperto il bruciatore non si accende) • VERIFICA PRESENZA ACQUA NEL CIRCUITO PRIMARIO • GRUPPO IDRAULICO IN PLASTICA + CONTATTO ELETTRICO A 2 FILI • ATTUALMENTE UTILIZZATO SOLO SU BASICA ED ARTICA • TRASDUTTORE DI PRESSIONE • SENSORE DI PRESSIONE (se la lettura che trasmette alla scheda è inferiore a quella di sicurezza impostata in scheda allora il bruciatore non si accende) • VERIFICA PRESENZA ACQUA NEL CIRCUITO PRIMARIO • GRUPPO IDRAULICO IN PLASTICA + SENSORE A 3 FILI • ATTUALMENTE UTILIZZATO SU TUTTO IL RESTO DELLA GAMMA

  13. GRUPPO DI MANDATA – BY PASS • BY PASS INTEGRATO • COMPONENTE DI SICUREZZA CHE GARANTISCE UN CORRETTO FLUSSO D’ACQUA SUL SCAMBIATORE PRIMARIO INDIPENDENTEMENTE DALLE CONDIZIONI DI CARICO DELL’IMPIANTO DI RISCALDAMENTO • DI SERIE SU TUTTE LE CALDAIE • AUTOMATICO NON TARABILE • COLLOCATO NELLA PARTE POSTERIORE DEL GRUPPO IDRAULICO DI MANDATA MANDATA RISCALDAMENTO

  14. GRUPPO DI RITORNO • GRUPPO DI RITORNO • POSIZIONATO SULLA PARTE DESTRA DELLA CALDAIA • MATERIALE COMPOSITO (BREVETTO BSG);COMPOSTO DA: • RUBINETTO DI RIEMPIMENTO • RUBINETTO DI SCARICO • VALVOLA 3 BAR • NTC INGRESSO SANITARIO(solo Inovia) • FLUSSIMETRO SANITARIO

  15. FLUSSIMETRO SANITARIO • COMPITO • DISPOSITIVO CHE INVIA UN SEGNALE ELETTRICO (AL CIRCUITO ELETTRONICO DI CONTROLLO) PROPORZIONALE ALLA QUANITA’ D’ACQUA PRELEVATA AD USO SANITARIO. • CARATTERISTICHE • GALLEGGIANTE CON MAGNETE A TURBINA POSIZIONATO IN VERTICALE • GALLEGGIANTE INTERAMENTE REALIZZATO IN MATERIALE PLASTICO PER EVITARE PROBLEMI DI CORROSIONE • CONTATTO ELETTRICO 5Vcc • FACILITA’ DI MANUTENZIONE • FILTRO ACQUA IN INGRESSO • PORTATA MINIMA 2,0L/min

  16. SCAMBIATORE SANITARIO • COMPITO • PRODURRE ACQUA CALDA SANITARIA ATTRAVERSO UNO SCAMBIO TERMICO ACQUA-ACQUA • CARATTERISTICHE • REALIZZATO CON PIASTRE IN ACCIAIO • GEOMETRIA A NIDO D’APE DELLE SUPERFICI DI SCAMBIO PER ELEVATA EFFICIENZA • FLUSSI DEI CIRCUITI IN CONTROCORRENTE • DATI • N° 12 PIASTRE 24 KW • N° 14 PIASTRE 28 KW • N° 16 PIASTRE 32 KW

  17. NTC USCITA SANITARIO • COMPITO • CONTROLLARE LA TEMPERATURA DI USCITA DELL’ACQUA CALDA SANITARIA • TRADUCE LA TEMPERATURA DELL’ACQUA IN SEGNALE ELETTRICO • POSTO IN USCITA DALLO SCAMBIATORE SANITARIO • A CONTATTO DIRETTO CON L’ACQUA

  18. NTC INGRESSO SANITARIO (Solo Inovia) • COMPITO • CONTROLLARE LA TEMPERATURA DI ENTRATA DELL’ACQUA SANITARIA • CARATTERISTICHE • STESSA SONDA DELL’USCITA • IDEALE PER ABBINARE LA CALDAIA ISTANTANEA CON UN SISTEMA SOLARE

  19. PRESTAZIONI SANITARIO

  20. SCHEMA IDRAULICO – VERSIONE SV Tre vie in riscaldamento Tre vie in sanitario

  21. GRUPPO ACQUA (VERSIONE SV) TRASDUTTORE DI PRESSIONE VALVOLA 3 BAR MOTORE VALVOLA 3 VIE MANDATA RISCALDAMENTO MANDATA AL SERPENTINO BOLLITORE RUBINETTO DI SCARICO RUBINETTO DI CARICO