1 / 15

Status of r eceivers related activities

Status of r eceivers related activities. Damien Prieur University of Pittsburgh. Receivers Software. Rx Gains - Online Software. Overhaul of L1GainDb & UsbController packages Improved USB communication Database access implemented Larg_L1MON_A & Larg_L1MON_C segments enabled

chelsa
Télécharger la présentation

Status of r eceivers related activities

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Status of receivers related activities Damien Prieur University of Pittsburgh L1Calo Joint Meeting - Heidelberg

  2. Receivers Software L1Calo Joint Meeting - Heidelberg

  3. Rx Gains - Online Software • Overhaul of L1GainDb & UsbController packages • Improved USB communication • Database access implemented • Larg_L1MON_A & Larg_L1MON_C segments enabled • Right on time before beam ! • Thanks to MurroughL., Fatih B. & Henric W. • Have to be moved out of the LArg segment (Tile/L1Calo calibration runs) • Receivers Strategy • Defines the set of receiver gains to be loaded • Selection through dropdown list in L1Calo panel • Must be set before CONFIG step ! • Controller communication issues • Few USB communication errors observed ~1% • Not critical, have to re-config the concerned segment L1Calo Joint Meeting - Heidelberg

  4. Rx Gains – Database Structure • Oracle INTR server • Store conditions before start of run • Strategy, final gains, DACs & status • Factor folders • 8192 channels/factors per folder • Define Strategies • One strategy = set of factor folders • Selected on L1Calo panel • Gains from different folders are factorized (per channel) L1Calo Joint Meeting - Heidelberg

  5. ET Calibration L1Calo Joint Meeting - Heidelberg

  6. ET Calibration • Gains produced in time for beam • Thanks to Veit Scharf & Antoine Marzin • EMB, EMEC, HEC, Tile • LArg/L1Calo energy scans • Match L1Calo to LArg offline energy • Use calibration OFCs • Corrections for high voltage, dead channels • Correction for disabled FEBs, dead OTX HAD EM 1.5 1.3 1 1 0.7 0.4 L1Calo Joint Meeting - Heidelberg

  7. ET Calibration EM • No calibration for FCAL yet • Technical issues to reconstruct LArg energy • Problematic towers • Few towers with non-optimal calibration • Sick TBB • EMB/EMEC overlap region • All trigger cable installed • Have to determine correct length HAD L1Calo Joint Meeting - Heidelberg

  8. Splashes • Correlation plot from Huaqiao Zhang • 3% bias for EMB and EMEC • To be investigated • TBB delays not appropriate • Set to calibration instead of physics • Few % deviation L1Calo Joint Meeting - Heidelberg

  9. B/EC Overlap Region L1Calo Joint Meeting - Heidelberg

  10. Overlap cabling EMB & EMEC overlap channels summed at the receivers level ‘octopus’ cable 37-pin to 4 x 9-pin connectors Barrel Receiver EMB Overlap ‘E’ connector VGA VGA EMEC Overlap + EMEC Receiver L1Calo Joint Meeting - Heidelberg

  11. Overlap cabling ‘E’ connectors 4 x 4-pair cables EMB Crate Breakout box Bill Cleland Pittsburgh EMEC Crate • All cables installed • Cables prod. & inst. • Michel Mathieu • Andrei Akimov 1 x 16-pair cable L1Calo Joint Meeting - Heidelberg

  12. Overlap timing from beam-splash events • Octopus cables 5S & 1S were in place • Set receiver gains to alternate the EMB/EMEC signal components vs phi connector 2 0 1 0 7 0 1 6 1 0 5 0 1 4 pair 1 0 3 0 1 2 1 0 1 0 1 0 EMB EMEC A-Side L1Calo Joint Meeting - Heidelberg

  13. Overlap timing from beam-splash events phi C-Side A-Side • TT to TT timing raisonnable for EMB • Unexpected offset between EMB & EMEC… EMEC EMB • Cables longer than nominal values • To be on the safe side • ~10-15 ns • Non nominal TBB delays • ~3-6 ns • Bug in length calculations • ~20 ns • Still 15-20 ns to be understood • PS rise time • ≠ energy fraction EMEC EMB EMEC EMEC EMB EMB 50 ns 63 ns [bc] [bc] L1Calo Joint Meeting - Heidelberg

  14. Tower Builder Boards delays • Calibration delays set until first collisions • Determined from single-layer phos4 runs • Then moved to physics delays • Based on calibration delays + LAr tool to get physics/calib. time difference • Central towers not timed • Caused by physics delays Ps Fr Md Bk eta=0.15 (0x00140500): 6 7 7 6 eta=0.05 (0x00100c01): 0 0 0 7 • Back layer is the culprit • Most probably bug in calibration cable length used to compute phys/calib difference L1Calo Joint Meeting - Heidelberg

  15. Ongoing work • TBB delays database, Paolo working on it • Understand physics delays at eta=0 • Barrel/End Cap overlap region • Have to accumulate data to check/compute timing • Understand discrepancies wrt computed values L1Calo Joint Meeting - Heidelberg