1 / 18

Status Report particle identification with the RICH detector

Status Report particle identification with the RICH detector. general overview focus on ring radius/ Cherenkov angle resolution Boris Polichtchouk: results from simulation. Claudia Höhne - GSI Darmstadt, Germany. particle identification with RICH. ring finding

curt
Télécharger la présentation

Status Report particle identification with the RICH detector

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Status Report particle identification with the RICH detector • general overview • focus on ring radius/ Cherenkov angle resolution • Boris Polichtchouk: results from simulation Claudia Höhne - GSI Darmstadt, Germany

  2. particle identification with RICH • ring finding • ring finder: Hough Transform, Elastic Net • to be implemented in framework • → efficiencies ... • determination of center and radius of ring/ Cherenkov angle • matching of rings with tracks • → tracking (momentum and position resolution), information from other detectors • pid by combining ring radius and momentum information •  detailed knowledge of resolution necessary!

  3. main contribution ! ring radius resolution • Cherenkov angle/ ring radius resolution limited by: • multiple scattering • magnetic stray field in RICH • emission point: particle trajectories do not pass through the center of curvature of the mirror  smeared projection in dependence on (,) • mirror surface: enlargement of focal spot in focal plane due to a deviation of the mirror surface from the ideal spherical curvature • pixel size: resolution limited due to finite granularity of photodetector • chromatic dispersion N2 radiator investigate single rings! resolution for overlapping rings different!

  4. 2% of qcmax ssingle = 2.5mrad single photon – ring resolution • distinguish between Cherenkov angle resolution for single photons sq • and the resolution for a ring sR consisting of N measured photons • table 1 from RICH-TDR of LHCb: • aim at doing a similar study

  5. [T. Ypsilantis, J.Seguinot, NIM A343 (1994) 30, P. Glaessel, NIM A 433 (1999) 17] multiple scattering momentum dependent error of form with typical value for a N2 radiator of 1m and p=1GeV: → for 2.5 m N2

  6. [T. Ypsilantis, J.Seguinot, NIM A343 (1994) 30, P. Glaessel, NIM A 433 (1999) 17] magnetic stray field momentum dependent error of form with being the particle angle relative to the magnetic field direction →

  7. asymmetric field gaussian shaped field magnetic stray field (II) RICH front wall z=170cm → magnetic stray field (By) of order 10mT length L=2.5m at maximum By [T] By [T] z [cm] z [cm]

  8. L2.5m, B=10mT → → p=1GeV [T. Ypsilantis, J.Seguinot, NIM A343 (1994) 30, P. Glaessel, NIM A 433 (1999) 17] magnetic stray field (III) momentum dependent error of form with being the particle angle relative to the magnetic field direction →

  9. one quarter of mirror/ photodetector: f = 80o 60o 40o q = 5o 10o 15o 20o 25o 30o 35o 20o emission point • rings(q,f) - q polar angle, • f azimuth angle • no diffusion at reflection • no magnetic field, no multiple scattering • to do: • quantify and correct for distortions at large q,f • improve focussing/ position of focal plane • correct for remaining distortions → restrict investigation of resolution to "good" area in central region and wait for optimized setup

  10. mirror surface • Be-mirror prototype: • optical surface roughness sh = 1.6nm (after glass polishing, Al covering and SiO2 coating) • → diffuse reflection of only 12% of total for l = 150nm • image diameter of a point source D0 = 0.4mm (contains 95% of reflected light) • → angular deviation from nominal curvature sR = 0.03mrad resulting radius resolution to be determined Ph.D. thesis of G. Hering (2002), CERES: ring center resolution of same order as local mirror deviation → sq < 0.1mrad

  11. pixel size • finite granularity of photodetector restricts resolution • simple estimate can be made from comparing padsize d and ring radius R / Cherenkov angle q d=0.6cm padsize R=5.5cm ring radius L=225cm radiator length → Boris Polichtchouk

  12. however, dN/dl also increases in UV region and • 4mrad • sq~2mrad (~0.4cm) [Landolt Boernstein Series, 6th Edition, volume II/8 Ph.D. thesis of Annick Bideau-Mehu (1982)] chromatic dispersion • strong increase of n(l) in UV region N2: l [nm] q [mrad] 600 24.42 200 26.15 150 28 100 36.75 N2 → Boris Polichtchouk

  13. total resolution (I) • multiple scattering sq ~ 1 mrad (p=1 GeV) • magnetic stray field sq < 1 mrad (p=1 GeV) • emission point sq small because of corrections, optimization • angular deviation of mirror sq < 0.1 mrad • chromatic dispersion sq > 1 mrad (strongly dependent on lmin) • pixel size sq ~ 1-2 mrad •  couple of mrad contributions, independent errors qc=24.4 mrad  sq ~2-3% of qc

  14. 1% 2% 3% 4% 5% total resolution (II) gaussian distributed Cherenkov angles/ radii → calculate separation power for e and p in terms of sq for different sq

  15. R ring – track matching • matching: combine track and ring with closest distance • ~ 2/3 of all rings from secondary interactions, very often not reconstructed • difficulty due to high particle mutiplicities  match ring to track (e.g. ) which is nearby additional source for p-misidentification

  16. pid versus R • ideal tracking: with of R –distribution due to method for ring center determination • finite tracking: distribution widened • cut on R important for efficiency and purity! 1% momentum resolution 1.3 mrad resolution in azimuth angle 0.8 mrad resolution in deep angle 200 m position resolution in mirror

  17. efficiency, misidentification - misidentification in dependence on a cut in R 35 AGeV: 827  / event   0.3/827 = 410-4 -misid. (R = 0.8 cm)  = 610-4 -misid. (60% acc.) efficiency of e-identification in dependence on a cut on R R = 0.8cm: > 95% ideal tracking finite resolution ideal tracking finite resolution

  18. summary/ outlook • particle identification with the RICH detector • aim: momentum dependent pid efficiency and purity • efficiency: ring finders to come • purity: started with detailed analysis of ring radius resolution •  for s=3% of qc we have 3s separation between e and p at 13.5 GeV/c • impact on detector layout: granularity of photodetector maximum wavelength range for photodetection • purity: extend tracking algorithms for extrapolation of tracks to photodetector plane • combine with information from other detectors

More Related