1 / 7

Mark A Collins Ph.D Marketing Manager, Cellular Imaging & Analysis

MIAHA - Minimum Information for a High Content Assay - a proposal for a standard for high content analysis data interchange. Mark A Collins Ph.D Marketing Manager, Cellular Imaging & Analysis. Review. Standard for Images and Data An image standard alone is not enough

dawn
Télécharger la présentation

Mark A Collins Ph.D Marketing Manager, Cellular Imaging & Analysis

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. MIAHA - Minimum Information for a High Content Assay - a proposal for a standard for high content analysis data interchange Mark A Collins Ph.D Marketing Manager, Cellular Imaging & Analysis

  2. Review • Standard for Images and Data • An image standard alone is not enough • To analyse an image between different packages need more than just it’s type and format • How acquired • Magnification • Filters etc • Need a standard for data interchange that uses appropriate meta data to describe HCS/HCA images and data • Self describing format of XML proposed • Embrace and extend two existing standards • OME – Open Microscopy Environment • http://www.openmicroscopy.org/ • MIACA – Minimum Information for ACellular Assay • http://miaca.sourceforge.net/

  3. Practical Implementation of a Standard • Not just talk • Draft specification for HCS/HCA Data Interchange completed • MIAHA • Minimum Information for AHigh Content Assay • Testing the standard • HCSGateway™ Cellomics open interface to third party readers • GE INCELL 1000/3000 • Evotec Opera • Implemented the standard as part of the HCSGateway product • Get third party data in to our informatics • Get third party data out

  4. Implementing a Standard – Generation 1 HCSGateway transform to MIAHA 3rd party Analysis software Instrument data & Images MIAHA XML Document & image links Webservices Webservices API natively “reads” and writes MIAHA XML standard Cellomics Store database

  5. Implementing a standard - Generation 2 Instrument/Analysis software directly writes/reads MIAHA XML data MIAHA XML Document & image links Webservices Webservices API natively “reads” and writes MIAHA XML standard Cellomics Store database

  6. Current Standard Usage • Generation 2 Implementation • Evotec Opera • GeneData Screener • ArrayScan • CellWoRx • Generation 1 Implementation • INCELL 1000 • INCELL 3000 • Other custom

  7. HCSGateway™ Open Instrument interface - implements MIAHA Cellomics Reader Family GE IN Cell Analyzer 1000 API CellWoRx* Reader HCSGateway Open Interface for Instrumentation GE IN Cell Analyzer 3000 Other Instruments Evotec Opera

More Related