1 / 8

PREX Magnet Measurements

PREX Magnet Measurements. John J. LeRose. Back of the magnet. 9. 9. 7. 7. 8. 8. +B. +B. 1. 2. 3. 1. 2. 3. 5. 4. 6. 6. 4. 5. In the center of the magnet measure the field at nine points in each gap These are hand held probe measurements. (i.e. not fantastically accurate).

deron
Télécharger la présentation

PREX Magnet Measurements

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. PREX Magnet Measurements John J. LeRose

  2. Back of the magnet 9 9 7 7 8 8 +B +B 1 2 3 1 2 3 5 4 6 6 4 5 In the center of the magnet measure the field at nine points in each gap These are hand held probe measurements. (i.e. not fantastically accurate)

  3. I = 523 Amps Right -Left 4 corners are a little high Cross at center fairly even Given the accuracy of the measurements looks pretty good

  4. Measured B vs. I • Attached probes to each pole in the same place • Measured B at several values of I • Cross checked probes at highest field • Placed right probe directly on top of left probe • B left probe = -447.1 mT; B right probe = -447.7 mT Polarity was backwards Right side is ~2.5% lower field than the left side Old news! Just measurement uncertainty

  5. Updates More careful remeasure eliminates the 2.5% offset -Thank you, Javier

  6. Updates cont’d TOSCA calculation agrees well with new measurements

  7. Other News • We now have right and left side SNAKE models of HRS with PREX septum • Both feature y|φ = x|θ = 0 and y|y ≈ 1 Right Left I’ll fine tune when you decide exactly where you’ll put the detector. Then I’ll generate the starting values of the reconstruction matrix elements.

  8. Conclusion • In general the magnet looks good. • Bleft = -Bright • Bmeasured = Bcalculated • Polarity was backwards during testing • no big deal • Polarityleft vs. Polarityright is OK • Still need final detector position