1 / 13

E166 Collaboration Meeting Princeton, 22-24 May 2006

Analyzer Magnetic Analysis. (Status Report) P. Sch ü ler (DESY). General Overview Spin and Magnetization Field Distribution Modeling Results from Flux and Field Measurements Electron Polarization of the Iron Remaining Work. E166 Collaboration Meeting Princeton, 22-24 May 2006.

dlowery
Télécharger la présentation

E166 Collaboration Meeting Princeton, 22-24 May 2006

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Analyzer Magnetic Analysis (Status Report) P. Schüler (DESY) • General Overview • Spin and Magnetization • Field Distribution Modeling • Results from Flux and Field Measurements • Electron Polarization of the Iron • Remaining Work E166 Collaboration Meeting Princeton, 22-24 May 2006 Analyzer Magnetic Analysis K. Peter Schüler

  2. General Overview M = manetization n = electron density μB = Bohr magneton g‘ = magneto-mechanical factor electron polarization of the iron: Pe≈ 0.07 ΔPe/Pe < 0.05 (aim of proposal) error in e- polarization is dominated by knowledge in effective magnetization M along the photon trajectory: active volume Photon Analyzer: 50 mm dia. x 150 mm long Positron Analyzer: 50 mm dia. x 75 mm long E166 Collaboration Meeting Princeton, 22-24 May 2006 Analyzer Magnetic Analysis K. Peter Schüler

  3. Spin and Magnetization g‘ = magneto-mechanical factor: obtained from Einstein - de Haas type experiments, related to gyromagnetic ratio: γ = (g‘/2) ∙ (e/m) Note: g‘ = 2  Ms / M = 1 (pure spin magnetization) γ = e/m g‘ = 1  Ms / M = 0 (pure orbit magnetization) γ = ½ (e/m) … and its ultimate implementation (Scott 1962) g‘ = 1.919 ± 0.002 for pure iron i.e. orbital effects contribute about 4% the principle E166 Collaboration Meeting Princeton, 22-24 May 2006 Analyzer Magnetic Analysis K. Peter Schüler

  4. Analyzer Magnets  Analyzer e+ Analyzer Pickup Coils CsI-Detector e+Analyzer E166 Collaboration Meeting Princeton, 22-24 May 2006 Analyzer Magnetic Analysis K. Peter Schüler

  5. end Field Distribution Modeling(Vector Fields OPERA-2d) Bz (T) 20 15 10 R = 0 mm Z (mm) center longitudinal field distribution: Bz (R,Z) field drops gradually towards the ends: Leff / L < 1 E166 Collaboration Meeting Princeton, 22-24 May 2006 Analyzer Magnetic Analysis K. Peter Schüler

  6. Field Distribution in 2d(Vector Fields OPERA-2d) Z (mm) R (mm) longitudinal field distribution: Bz (R,Z) E166 Collaboration Meeting Princeton, 22-24 May 2006 Analyzer Magnetic Analysis K. Peter Schüler

  7. Pickup Coils for Flux Measurements: used 4 turns of special coil wire with 40 wire strands: externally wired in series for 4 x 40 = 160 turns max. (*) positron downstream became dysfuntional after Oct. 2004 at SLAC (**) photon upstream was damaged already at DESY E166 Collaboration Meeting Princeton, 22-24 May 2006 Analyzer Magnetic Analysis K. Peter Schüler

  8. Flux Measurements: measure voltage transients in pickup coils upon current reversals data taken by Zen - analyzed by Roman Positron Analyzer (-60  +60 amps) Photon Analyzer (-60  +60 amps) Sawtoothfrom Waveform Generator (for calibration of time base) E166 Collaboration Meeting Princeton, 22-24 May 2006 Analyzer Magnetic Analysis K. Peter Schüler

  9. Flux Data: E166 Collaboration Meeting Princeton, 22-24 May 2006 Analyzer Magnetic Analysis K. Peter Schüler

  10. Flux and Field Measurements: Results Z = 0 (center) Note:polarimetry was always done at full saturation over the central region (±60A) E166 Collaboration Meeting Princeton, 22-24 May 2006 Analyzer Magnetic Analysis K. Peter Schüler

  11. Flux and Field Measurements: Z = -20 mm No significant field difference seen between „upstream“ and „center“ E166 Collaboration Meeting Princeton, 22-24 May 2006 Analyzer Magnetic Analysis K. Peter Schüler

  12. electron polarization of the iron preliminary result for the e+ analyzer: (6.94 ± 0.17) % - and the nitty-gritty: E166 Collaboration Meeting Princeton, 22-24 May 2006 Analyzer Magnetic Analysis K. Peter Schüler

  13. Remaining Work • repeat magnetic modeling with correct • central field values as measured • choose finer mesh spacing • same for photon magnet • generate writeup E166 Collaboration Meeting Princeton, 22-24 May 2006 Analyzer Magnetic Analysis K. Peter Schüler