1 / 12

AP BIOLOGY LAB 4B Photosynthesis

AP BIOLOGY LAB 4B Photosynthesis. DPIP. When chloroplasts are exposed to light, electrons reduce NADP + to NADPH. ELECTRON ACCEPTOR. DPIP= substitute for NADP + DPIP ox = BLUE DPIP re = colorless. SPECTROPHOTOMETER. Measures % light transmitted

dolph
Télécharger la présentation

AP BIOLOGY LAB 4B Photosynthesis

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. AP BIOLOGYLAB 4BPhotosynthesis

  2. DPIP When chloroplasts are exposed to light, electrons reduce NADP+ to NADPH

  3. ELECTRON ACCEPTOR • DPIP= substitute for NADP+ • DPIPox = BLUE • DPIPre = colorless

  4. SPECTROPHOTOMETER • Measures % light transmitted • If DPIP is oxidized (blue) % transmittance will be low • If electrons are excited and move to reduce DPIP(colorless) % transmittance will increase

  5. SET UP LIGHT SINK Image modified from Holtzclaw & Holtzclaw Study Guide

  6. Cover tube # 2 completely with foilMake a removable foil top

  7. SET UP TUBES Add Phosphate buffer, distilled water, & DPIP totubes as shown WAIT TO ADD CHLOROPLASTS!

  8. SPECTROPHOTOMETER • BLANK has all ingredients except DPIP • Use Blank to calibrate machine • Spectrophotometer is not digital • Slow to respond • Adjust dial and WAIT!BE PATIENT!

  9. ZERO MACHINE • Place BLANK in chamber and close lid • Slowly turn dial on front until window reads 100% (Wait for lag time!) • 100% with blank • 0% with no tube/door closed

  10. Add 3 drops of UNBOILED CHLOROPLASTS to tube #2 • Put Parafilm on top and gently mix • Remove from foil sleeve and immediately put sample in chamber, read % transmittance, and record in lab book • Remove sample from chamber and return to foil sleeve, cover and place in test tube rack under light • Start timer • Take and record readings at 5, 10, & 15 min

  11. REPEAT WITH EACH TUBE • You can run multiple timers • Just make sure you stagger time points so you are not taking readings of multiple tubes at same time • Use cuvette #1 (blank) occasionally to check and adjust the spectrophotometer to 100% transmittance

  12. Image modified from Holtzclaw & Holtzclaw Study Guide

More Related