An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. بسم الله الرحمن الرحيم

  2. Multi-Slice CTShort Notes On Clinical ApplicationBy Dr. TAREK AHMAD RAAFAT Ass. Lecturer Radiodiagnosis National Cancer Institute Cairo University

  3. Physical Principles of Multi-Detector CT

  4. Multiplied Computed Tomography (MSCT) was introduced in the field of radiology in 1998 resulting in revolution of imaging and addition of a new clinical applications. • The benefits of multi-detector CT relative to single-section CT are significant. • The examination can be done with thinner sections, and much faster resulting in improved resolution and reducing the motion artifacts. • MDCT can cover a distance 8 times longer than single-slice CT.

  5. There are 2 main differences between ordinary spiral CT machines andMDCT :- 1- It allows the acquisition of multiple axial images with a single gantry rotation. 2- It has shorter gantry rotation period making it much faster.

  6. Scanning Speed • MDCT scanners have gantry rotation period of 0.5 sec, twice the speed of most conventionalhelical scanners. • Therefore, a MDCT scanner with 4 data channels is up to 8 times faster than a conventional single-slice CT scanner.

  7. Clinical Applications • Multisection CT aquires changes in the planning and staging of patient examinations. The scanning time is reduced for most examinations, requiring adjustments in the administration of intravenous contrast material. The amount of contrast material can be reduced, and different vascular phases can be better visualized. Thin-section scanning allows production of high-quality MPR images

  8.  Coronal reformation image of the right temporal bone created from an axial multisection

  9. (a) Coronal MPR image clearly shows a pin penetrating the posterior subtalar joint (arrowheads). (b) Sagittal MPR image clearly shows secondary degenerative changes (arrows). Streak artifacts are remarkably mild given the large amount of steel.

  10. Thin-section CT of the hip (a, b) Coronal (a) and curved oblique sagittal (b) reformation images show fine detail. (c) Lateral surface-rendered image shows the acetabulum and femur together.

  11. (a) Coronal maximum-intensity projection image shows the sacrum with metal appliances. (b) Curved reformation image shows the sacroiliac joint surfaces and bone grafts (arrow).

  12. (a) Sagittal image shows that the multisection acquisition will avoid dental hardware and the associated artifacts. (b, c) Coronal (b) and sagittal (c) reformation images show mucoperiosteal thickening.

  13. Bone Tumors

  14. (a) Sagittal reformation image shows excellent bone detail and the outline of the subarachnoid space. (b, c) Corrected-axis MPR image (b), which was obtained along the dashed line in a, has the same spatial resolution as an original axial image

  15. Duodenal carcinoma. (a-c) Axial (a), coronal (b), and sagittal (c) images show a dilated common bile duct (I) and a duodenal neoplasm (arrows). (d, e) Lateral arterial-phase (d) and anterior venous-phase (e) maximum-intensity projection images show normal vessels.

  16.   Bilateral carotid artery stenosis. Coronal maximum-intensity projection image from CT angiography performed from the arch to the skull base (1.0-mm section thickness, 19-cm longitudinal coverage, 0.5-mm longitudinal reconstruction interval) shows severe stenosis of the left internal carotid artery (arrow).

  17. Renal artery stenosis in a hypertensive patient imaged with CT angiography

  18. Renal Angiography

  19. Endovascular repair of an aortic aneurysm with stent-grafts

  20. Virtual Endoscopy

  21. CTcoronary angiography is becoming feasible with the availability of faster multisection imaging.

  22. CONCLUSION • Multisection CT is superior to single-section helical CT for nearly all clinical applications. The superior speed of the former can be used to improve the temporal, spatial, and contrast resolution of the images. In addition, multisection CT shows promise for clinical applications that were limited or impossible with single-section helical CT, such as cardiac imaging, organ perfusion studies, and examinations of multiple vascular phases. It also brings isotropic imaging into the CT domain. CT has reached the brink of a new era.