1 / 16

Measurement of mains decoupling and/or mains coupling loss - running discussion in CISPR/A

Measurement of mains decoupling and/or mains coupling loss - running discussion in CISPR/A. Conducting coupling Discussion in CISPR/A/WG2 and CISPR/H/WG2 Concept of the mains decoupling factor Concept of the mains coupling loss Content of to be drafted CD Action in CISPR/A/WG2.

edric
Télécharger la présentation

Measurement of mains decoupling and/or mains coupling loss - running discussion in CISPR/A

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Measurement of mains decoupling and/or mains coupling loss -running discussion in CISPR/A • Conducting coupling • Discussion in CISPR/A/WG2 and CISPR/H/WG2 • Concept of the mains decoupling factor • Concept of the mains coupling loss • Content of to be drafted CD • Action in CISPR/A/WG2 L. Dunker / BNetzA/413a

  2. Conducting coupling L. Dunker / BNetzA/413a

  3. CISPR Report 31: Mains decoupling factor /1967 L. Dunker / BNetzA/413a

  4. CISPR/A(Sec)67/1985 L. Dunker / BNetzA/413a

  5. CISPR/A(Sec)67/1985 L. Dunker / BNetzA/413a

  6. Conducting coupling: Measurement procedure L. Dunker / BNetzA/413a

  7. Conducting coupling: Measurement procedure Symmerical feeding Radio dummy L. Dunker / BNetzA/413a

  8. Result of CISPR/H/WG2 and CISPR/A/WG2 meeting in Cape Town • A concept (CISPR/A/WG2(Battermann/ Dunker) for for the estimation the conducting coupling by the AC-mains was presented in CISPR/H/WG2 and CISPR/A/WG2 • This concept of the conducting coupling takes into account the characteristics of the AC-mains which have different attenuation for symmetrical and asymmetrical disturbance emissions. • The concept deviates from the old CISPR/A/Sec)67; July 1985 • CISPR/H/WG2 is interested in this measurement procedure and its results for the weighting of limit on mains • CISPR/A/WG2 decided to prepare a draft CD for the measurement equipment and the measurement procedure and to involve CISPR/WG3 in this topic L. Dunker / BNetzA/413a

  9. Concept of the mains decoupling factor • The mains decoupling factor [dB] is defined for the measurement of: • U0 measured on the test site • U1 measured at the antenna’s feed-point L. Dunker / BNetzA/413a

  10. Concept of the mains decoupling factor Results of the DM,asym and DM,sym measured in a modern installed flat at 19 sockets (Voltage at 50 Ohm) L. Dunker / BNetzA/413a

  11. Concept of the “coupling loss” • The coupling loss of the mains [dB] is the transfer function between two point in a network without constant impedance which can be measured by the disturbance current. • The coupling loss is defined as: L. Dunker / BNetzA/413a

  12. Concept of the “coupling loss” Results of the CL,M,asym and CL,M,sym measured in a modern installed flat at 19 sockets L. Dunker / BNetzA/413a

  13. Content of to be drafted CD • Definitions and characteristic of conducted coupling: • Definitions of mains decoupling • Definitions of coupling loss • Estimation of maximal allowed disturbance voltage • Requirements to the artificial disturbance source • Output voltage (symmetrical and asymmetrical) • Impedances (symmetrical and asymmetrical) • Conditions for the connection to PE (Battery powered or mains powered) • Requirement to the “coupling device” L. Dunker / BNetzA/413a

  14. Content of to be drafted CD • Requirement to the radio dummy • Size and type of the radio case and stick antenna • Input impedance to the dummy connected with the stick antenna (impedance converter of CISPR 25) • Mains connection from dummy case (capacitive) • Powered by battery • Indication of voltage at the feed-point of the stick antenna (battery powered receiver or spectrum ananlyzer) • Conditions for the connection to PE L. Dunker / BNetzA/413a

  15. Content of to be drafted CD • Measurement procedure • Measurement on the test site (asymmetrical and symmetrical voltage) • Handling of disturbance source and radio dummy (e. g. distance to the environment,…) • Measurement of the voltage at the antenna feet-point (mains decoupling) or the currents (coupling loss) • Calculate the wanted values: mains decoupling or coupling loss by mean and standard deviation • Estimation of the symmetrical decoupling of the mains taking into account mean, standard deviation and the t-quantile L. Dunker / BNetzA/413a

  16. Action in CISPR/A/WG2 • Discussion of the draft CD during the midterm meeting in Frankfurt and decision for further actions • It is expected that the CD is basically accepted and this CD is published short after the meeting. • The next discussion in CISPR/A could be at the meeting in Sweden. • Any comments / cooperation from / with CISPR/I/WG3 are / is welcome. L. Dunker / BNetzA/413a