1 / 11

Combined escape route and emergency fire luminaire Titania

Combined escape route and emergency fire luminaire Titania. Beghelli-Elplast has developed new luminaire Titania, which fully meet valid directives for the equipping of road tunnels. BEGHELLI - ELPLAST,a.s. 2010. 1. Luminaire Titania has been developed and designed in accordance with the

elias
Télécharger la présentation

Combined escape route and emergency fire luminaire Titania

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Combined escape route and emergency fire luminaire Titania Beghelli-Elplast has developed new luminaire Titania, which fully meet valid directives for the equipping of road tunnels. BEGHELLI - ELPLAST,a.s. 2010 1

  2. Luminaire Titania has been developed and designed in accordance with the latest edition of RABT Regulations for the equipment and operation of road tunnels Approved by German Federal Ministry for Traffic, Building and Urban Affairs This combined escape route and emergency fire light Titania helps to showvehicle passengers the fastest and safest way out of the tunnel in extreme cases. 2

  3. Titania According to the German Federal Ministry of Transport For all traffic tunnels that are longer than 400 m must be installed with emergency fire and escape route luminaire 3

  4. Titania 20 m 1,2 m Combined escape route and emergency fire luminaires 4

  5. Titania Power supply The norm establishes that when a tunnel suffers from a failure of power supply, an emergency powersupply system and an emergency lighting system must be at hand. Options • Second independent power supply from • distribution network • Independent source of electrical energy (generate by using genset – • Engine-generator, a machine used to generate electricity) • and - UPS (UninterruptiblePower Supply Source, to allow time to bring • an auxiliary power source on line). Operating voltage: 230V 5

  6. Titania Technical features: • Diffuser: • 4 mm safety tempered glass • Pictogram size: • 300 x 300 mm according to RABT • The body: • Stainless steel 1.4571 • Dustproof and waterproof • protection type IP 65 • protected against water jet cleaning 5 years guarantee 6

  7. Titania Special gasket for IP65 Higly polished reflector from AL Terminal block 5x2,5mm2 Tube clamps for through wiring 7

  8. Titania Dimensions according to RABT Bevelled edges (to avoidinjury of running people during accident) 594 mm Thickness 60 mm 474 mm 8

  9. Titania Safety and security Special key for opening Weight 8,3 kg 9

  10. Titania • LED identification lights: • There is 6 LEDs Osram Golden Dragon Oval Plus inside of the housing • Luminous intensity 75cd/m2 (RABT) • LED emergency fire lights: • The internal lighting consists of 2 cool white • 6300K high performance LEDs. • For additional security, they are linked in • such a way that should one LED ever • fail, the others remain light. Primary electrical circuit -14,5W Secondary electrical circuit – 9W Total – 23,5W All LEDs are protected behind safety glass 10

  11. Titania Summary of technical data Energy consumption: 23,5W (14,5W+9W) Degree of protection: IP 65 Shock protection: IK09 (5 Joule) Standards and certificates Vibration test EN 60068-2-64 Impact resistance EN 60598-1 Change of temperature Class T2 (-25°C / +55°C) IEC 60068-2-14 Damp heat Class T1/T2/T3 (+40°C) EN 60068-2-30 Water ingress Class IP65 EN 60529 Dust ingress Class IP65 EN 60529 Corrosion test (Salt spray test) 11