1 / 17

Metering, measurement & energy performance

Metering, measurement & energy performance. Expert in energy intelligence. ENERIUM power monitoring device. June 2015. The historic expert in power monitoring. Enerdis’s expertise to build your strategy for consumption monitoring and LV- MV electrical installation supervision.

emlyn
Télécharger la présentation

Metering, measurement & energy performance

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Metering, measurement& energy performance • Expertin energy intelligence ENERIUM power monitoring device June 2015

  2. The historic expert in power monitoring Enerdis’s expertise to buildyourstrategy for consumption monitoring and LV- MV electrical installation supervision • Successful integration in an existing architecture • Interfacing with all devices of the electrical environment • Selection of measuring device to suit the grid and • application needs • Processing of information (locally or remotely) For more than 25 years, Enerdis has been designing and manufacturingits range of power monitoring devices in France to meetcustomers' needsworldwide

  3. ENERIUM : A focus on electricityassessment • Monitor the energy bill • Check the installation's behaviour • Assess power quality kWh kVAh 4Q measurement Power Demand and Max Power Demand Loadcurve Real time V-U-I-P-Q-S-F Min-Mean-Max values Alarm on thresholds Trend curve THDiTHDu IndividualHarmonics (up to 50th rank) EN50160 check Quality-eventlogging Waveformrecording

  4. ENERIUM : Power monitoring device • Adaptation to all • the mechanical • constraints • Accurate • in demanding applications • and environments Screenless version for DIN-rail mounting or plate mounting Flush-mounted version 96x96 Or 144x144 for highervisibility Multi -measurement: Class 1 to 0.2 (IEC 61557-12) Active energy: Class 1 to 0.2s (IEC 62053-22) Reactiveenergy: Class 2 to 0.5s (IEC 62053-24)

  5. ENERIUM : Power monitoring device • Interoperability with • all upstream/downstream • systems • Long-term consumption analysis and electrical event tracking • with suitable load and trend curves* • Data Collection and transmission • via a wide range of digital or • analogue input/output possibilities • Remote access through • Ethernet or RS485 Modbus • communication Analyze 10min electrical feeder demandefficiency Trigger trend curverecording on Alarms (threshold, inputs, etc.) Compare hourly time-stamped utility consumption data

  6. ENERIUM : Power monitoring device

  7. ENERIUM : Power monitoring device • Intuitive • Display • Advanced • energy quality • features • Waveform Capture

  8. ENERIUM : Power monitoring device • Use Eview to manage communication with your Enerium • Quick configuration of the equipment • Possibility of importing and exporting a configuration • View of all instantaneouselectricalparameters • Memorize quick reconnection information • Download all trend curves, loadcurves, • waveforms and alarms table • Local data collection • The front IR communication port offers a reliableway to obtain all the • product information withoutopening the cabinet • Simplify installation behaviour checking with customizable display • Provideeasyaccess to the application's main electricalquantities on the samescreen

  9. ENERIUM : Power monitoring device A comprehensive PMD range • Most requiring • application • E100 E200 E300 • General purpose • application • E30 E50 E150

  10. ENERIUM : Power monitoring device The PMD range thatstands out from the crowd • E30 • E300 • E150 • Simple and effective • Designed for general-purpose • applications • Quick programming • Intuitive navigation • - RS485 communication built-in • An expert eye on the main feeder • Quality of LV and HV electrical networks • Monitoring of EN50160 compliance • Detection of voltage dips and surges • - Waveform capture • - Class 0.2s • Advanced electrical check • Save the electricalbehaviour of your installation • Trend curve and loadcurverecording • Harmonic by rankanalysis • - Ethernet communication built-in

  11. ENERIUM : Power monitoring device

  12. ENERIUM : Power monitoring device

  13. ENERIUM : Energycontracttuning • Barcelona Metro in Spain • 50x E150 for power management • and contract tuning in commercial premises throughout the subway substations • Abidjan harbour in Ivory Coast • The second most important harbour of Africaisequippedwith more than 300 Ulys energymeters and Enerium PMDs. This fleet of equipmentprovidesloadcurves and energyconsumption data used to rebill the privatecompaniesworking in the harbour.

  14. ENERIUM : Energy production monitoring • Gas powerplant in the Netherlands • 4x E300 are giving the critical THD level indication necessary to regulate the start-up of the installation's 4 feeders. • With its 2x25MW, this backup power station supports the network at times of peak electricity demand and is operated by GDF Suez. • Solar power plant in Southern Africa • 70x E100 and E300 for power management accompanying the construction of a 60 MW solar power plant in the city of Boshof, a substation and facilities required for connection to the 132 kV ESKOM network

  15. ENERIUM : Spot energyconsumption • Coca Cola factory in Santiago (Chile) • Dozens of Enerium monitors provide relevant energy consumption information concerning 10 varied production lines and auxiliary systems to an Eonline supervision system. This action was part of the LEED environmental certification project for this 5-year-old production site (the 2nd largest in South America) . • Autoliv production site in Paris • Autoliv is a worldwide player automotive safety systems. • 50 Enerium and Ulys meters connected to an Eonline software system measure and collect consumption data from this site, which is powered 50% by electricity and 50% by gas. • The production site is ISO50001-certified.

  16. ENERIUM : T&D network surveillance • T&D substation in Ivory coast • More than 250 Enerium 200s are installed in 46 substations in the Ivory Coast electricity T&D network. • The equipment provides accurate electrical quantities which meet the dispatching centre's monitoring needs and includes a troubleshooting tool for maintenance with its embedded trend curves. • Medium voltage cubicle OEMs • The Enerium product range offersfeaturescomplyingwithmostdemandingembeddingenvironments, such as medium voltage apparatus and switchgear. In the CzechRepublic , ABB's OEM business has delivered 300 productsincorporating Enerium devicesworldwide.

  17. ENERIUM : Power monitoring device Thankyou for your attention

More Related