This presentation provides a comprehensive overview of the AurorA2000 system setup, including a review of the previous AurorA99 configuration. Key features include detailed instructions for establishing connections using AuroraNet, setting up the V800MIU-3, and configuring the new V1400X-DVC-3 system console screens. It discusses maximum connection limits, recommended RS-485 configurations, and the preferred regulatory methods for system termination. This guide serves as an essential resource for engineers at Vicon Industries, Inc. looking to optimize their AurorA2000 environment.
AurorA2000 Setup Overview and Configuration Guide
E N D
Presentation Transcript
AurorA2000 Presentation 6/14/2001 Chris Stevens, Engineering Engineering Department Vicon Industries Inc.
Overview • Review of AurorA99 Setup • AurorA2000 setup with AuroraNet • Use of the V800MIU-3 • New V1400X-DVC-3 (System Console) Screens • New AurorA2000 Termination Setup
Review of AurorA99 Setup Maximum RS-485 connections: 8 System Consoles/V800KBDs 8 MIUs (each containing a maximum of 4 devices) Or 32 MIUs (each containing one device maximum)
AurorA2000 Setup Maximum AurorANet (RS-485) connections: 79 total additional devices 16 System Consoles/A2K-KBDs 32 AurorA2000s 8 MIUs (each containing a maximum of 4 devices) Or 32 MIUs (each containing one device maximum)
Configuring Serial Ports For AurorANet: Mode: AurorANet Baud Rate: 9600 bps Data Bits: 8 Parity Bits: None Stop Bits: 1 Type: RS-485
AurorANet Protocol Note: The preferred method is using the provided AurorANet Termination Box.