An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Thermal-Scheduling For Ultra Low Power Mobile Microprocessor George Cai1 Chee How Lim 1 W. Robert Daasch2 Intel Corporation 1 Integrated Circuit Design and Test Laboratory PSU 2

  2. Presentation Outline • Mobile CPU Power Efficiency With Demanded Performance • Thermal Scheduling For Mobile Microprocessor • Power Constrained Performance • Observations/Conclusions

  3. Primary OOP EX FE DE RF Secondary DE IOP Ultra Low Power Mobile Microprocessor • Primary pipeline: maximal performance, complex pipeline structure • Second pipeline: Minimum power and energy consumption, very simple in order structure and target mobile anywhere-anytime applications. • Transparent to OS and applications • Maximal utilizing on die clock/power gating for energy saving Majority mobile apps with performance requirements Text email, caller-id, reminder and other none high performance w/ anywhere-anytime requested apps

  4. Low Energy Consumption With Providing Suitable Performance Is Key For “Anywhere And Anytime” • Must be compatible with exist OS and platform • Must have active leakage power control • Must meet the real time telecom application requirements Stock/Urgent Messages All urgent message And important news News headline Email titles Calendar reminder Pages/voice message Alert Interactive command and reply Stock Update

  5. Primary OOP EX FE DE RF Secondary DE IOP Runtime Thermal Scheduling Capability • When thermal threshold is exceeded, the pipeline clusters will service instructions in alternating manner: cool the “hot” pipeline by clock/power-gating & the “cold” pipeline sustains processor operations • Flexible selecting the threshold point, the energy-delay product, performance, and reliability of the processor can be enhanced

  6. Thermal Effects: Leakage Trend • Active leakage power reduction will be significant role for total power reduction • Thermal control is important for low energy consumption for mobile CPU Derived from F. Pollack’s Micro-32 Keynote Presentation, 1999

  7. T1 TL T1 < TH & T2 TL T1> TL Tmax T1 TL T1 TH || T2> TL TH Temperature (C) T1 TL T1 TH TL T1> TL T1> TL Ta tcycle & T2 TH tcool theat & T2< TH Time (s) S1: Normal Operation (Primary Pipeline) S2: Stall Fetch & Clear Pipeline S3: Alternate Operation (Secondary Pipeline) S4: Disable Clock or Scale F-V S4 S3 S2 S1 Example of Scheduling Algorithm TS1 TS2

  8. Dynamic Frequency Scaling Dynamic Clock Disabling/Throttling Enhance Effectiveness Of Other Power Control Techniques

  9. Power Constrained Clock Frequency With Performance Impact

  10. Thermal Effects on Power • Divide total power into two components: dynamic and leakage power

  11. Thermal Effects on Energy • Using power per frequency (W/MHz) metric as proxy for energy

  12. ~15% ~30% Architecture-LevelPower-Performance Tradeoff • For wide-superscalar processors, performance impact of pipeline scaling is smaller than global clock throttling or frequency scaling

  13. Comparative Outcomes: Energy Metric • Simulation Conditions (500 million instructions; TL = 55C) • Stop Clock Control: Toggle between Fmax and 0 MHz • Voltage/Freq Scaling : Toggle between Fmax and 0.9/0.8/0.6 Fmax • Thermal Scheduling : Toggle between Primary and 2nd Pipelines Conservative: TH = 70C Aggressive: TH = 60C Energy Consumption of Aggressive Control Energy Consumption of Conservative Control 14.000 16.000 12.000 14.000 12.000 10.000 10.000 Energy (J) 8.000 Energy (J) 8.000 Benchmarks Benchmarks 6.000 6.000 PERL 4.000 4.000 PERL GCC 2.000 GCC 2.000 LI 0.000 LI M88KSIM 0.000 M88KSIM M88KSIM Clk Gating M88KSIM LI F-V Scaling LI Clk gating Thermal Scheduling V-F scaling GCC GCC Thermal scheduling Thermal Control Thermal Control PERL PERL Techniques Techniques

  14. Comparative Outcomes: Energy-CPU Time Metric Total Energy x CPU Time

  15. Pros and Cons • Advantages • Limits power/energy upper bound & prevents thermal runaway • Pipeline tuned for either performance or ultra low power • Existing OS and application compatible • Performance penalty for engaging/disengaging control is small (architecture event) • Supports low-power anywhere-anytime of mobile computing • Non-timing critical tasks • Real-time application that requires more predictable output • Concerns • i/t during pipeline switch • Real-Register File may require extra dedicated ports • Bypass bus may have additional loading