1 / 18

3RT contactors  75HP

Competitor analysis. Schneider Electric Moeller ABB Allen Bradley GE / AEG Sirius. 3RT contactors  75HP. 45. 85. Contactors  75HP (1/5). Schneider Electric Moeller ABB Allen Bradley GE / AEG. 45. 45. 75. LC1-K06/K09/K12/K16 2.2 / 4 / 5.5 / 7.5kW. LC1-D09/D12/D18

Télécharger la présentation

3RT contactors  75HP

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Competitor analysis Schneider Electric Moeller ABB Allen Bradley GE / AEG Sirius 3RT contactors  75HP

  2. 45 85 Contactors  75HP (1/5) Schneider Electric Moeller ABB Allen Bradley GE / AEG 45 45 75 LC1-K06/K09/K12/K16 2.2 / 4 / 5.5 / 7.5kW LC1-D09/D12/D18 5 / 7.5 / 10HP LC1-D25/D32/D38 15 / 20 / 25HP LC1-D40/D50/D65 30 / 40 / 50HP LC1-D80/D95 60/60HP S00 S0 S2 S3 3RT101 3RT102 3RT103 3RT104 3/5/7.5HP 5/7.5/10/15HP 20/25/30/40HP 50/60/75HP 45mm 45mm 55mm 70mm

  3. Contactors  75HP (2/5) - Dimensions: From LC1-D40 - D65 (30-50HP) - wider than SIRIUS Schneider Electric Moeller ABB Allen Bradley GE / AEG - Connection system: Contacts can only be changed from 75HP and upwards SIRIUS:Possible from Size S2/ 25HP & up  Up to 60HP, terminal box cannot be removed  Busbar/cable lug connection not possible SIRIUS: Possible from Size S3/ 50HP & up  Different insertion-depth for the main conductors for LC1-D09- D16  It is possible to accidentally clamp on the insulation  The maximum cable cross-sections for the appropriate rated currents cannot be connected

  4. Contactors  75HP (3/5) Auxiliary and control conductor connections: Up to 30HP, the auxiliary and coil conductors are always wired-up through the contactor SIRIUS: Four-terminal coil S0 - S3 A1 - Schneider Electric Moeller ABB Allen Bradley GE / AEG A2 - Label: The coil label cannot be read when the contactor is mounted SIRIUS: The complete catalog number can be read from the front - Materials/environmental compatibility: Contains some halogens + Dimensions/series:  Small and compact series K contactors from 3 HP upwards in comparison to S00  Depth up to LC1-D95/ 75HP is generally lower (even with the integrated auxiliary contact)  Auxiliary contacts: 1NC+1NO integrated up to LC1-D38/ 25HP ; access from the front (refer above)

  5. Contactors  75HP(4/5) + Connection system: Ring cable lugs can be used to connect main conductors ofLC1-D09/ 5HP to LC1-D38/ 25HP Schneider Electric Moeller ABB Allen Bradley GE / AEG - Restriction: Ring cable lugs cannot be used for auxiliary and control cables + Coil energization: Generally a wider operating range for DC coils: 0.7 - 1.25 Vs + Safety cover: The front cover to prevent accidental actuation is provided as standard (cover for the auxiliary contact coupling;the cover is thrown away for Hischa mounting) SIRIUS: The main contact coupling is recessed in the outer contour to protect it against accidental actuation. A sealed safety cover is available as an accessory.

  6. Circuit - Breakers Soft Starters Contactors - Air Break - Vacuum Contactors  75kW(5/5) Size S00 S0 S2 S3 S6 S10 S12 TeSys scope Combined with 3 VL circuit-breakers Schneider Electric Moeller ABB Allen Bradley GE / AEG Overload Relays - Thermal Overload Relays - Electronic TeSys only covers part of the modular SIRIUS system - only contactors 3 to 30 HP have been re-developed with the Quickfit technology, otherwise just a face-lift

  7. 45 45 45 Contactors  75HP (1/3) Schneider Electric Moeller ABB Allen Bradley GE / AEG 60 70 100 DILEEM / EM 3 / 5HP DIL00M/AM 5 / 7.5HP DIL0M/AM 10 / 15HP DIL1M/AM 25 / 30 HP DIL2M/AM 40 / 50HP DIL3M/AM 60 / 75HP S00 S0 S2 S3 3RT101 3RT102 3RT103 3RT104 3/5/7.5HP 5/7.5/10/15HP 20/25/30/40HP 50/60/75HP 45mm 45mm 55mm 70mm

  8. Contactors  75HP (2/3) - Series:  Width: 25/ 30HP: 60mm / SIRIUS: 55mm 40HP: 70mm / SIRIUS: 55mm 60/75HP: 100mm / SIRIUS: 70mm  4 widths up to 75HP / SIRIUS: 3 widths  No standard, unified design Schneider Electric Moeller ABB Allen Bradley GE / AEG - Endurance: DILEEM/ EM small contactor: Electrical and mechanical endurance is significantly lower than our S00: Mechanical: 10 million operating cycles / SIRIUS: 30 million oper. cycles Electrical: 1.2/0.75 million op. cycles / SIRIUS: 2/ 1.5 million op. cycles  DC operating system: For 60/75HP, mechanical endurance: LD: 3 million operating cycles. SIRIUS: 10 million operating cycles - Permissible ambient temperatures: Up to 30kW max. 50°C / SIRIUS: 60°C

  9. Contactors  75HP (3/3) - Accessories: Wiring connectors for reversing combinations - only up to 30HP SIRIUS: 400HP Wiring connectors for star/delta combinations - only up to 50HP SIRIUS: 400HP Schneider Electric Moeller ABB Allen Bradley GE / AEG - Wide operating range: There are no contactors available with a wide operating range (e.g. coupling relays) - Coil terminals: Three terminal coil: This causes restrictions when directly mounting protective devices / SIRIUS: 4-terminal coil + Dimensions: Standard low depth - less than SIRIUS + Small contactor: Compact DILEM/ DILEEM small contactor (low depth)

  10. 47,5 44 Contactors  100HP (1/3) Schneider Electric Moeller ABB Allen Bradley GE / AEG 54 70 90 B6-30/B7 5 / 7.5HP A9-30/A12 /A16 5 / 7.5 / 10HP A26-30/A30/A40 15/ 25/ 30HP A50-30/A63/A75 40 / 50 / 60HP A95-30/A110 745/ 100HP S00 S0 S2 S3 3RT101 3RT102 3RT103 3RT104 3/5/7.5HP 5/7.5/10/15HP 20/25/30/40HP 50/60/75HP 45mm 45mm 55mm 70mm

  11. Contactors  100HP (2/3) - Coil terminals: Three-terminal coil: Restrictions when directly mounting protective devices/ SIRIUS: 4-terminal coil Schneider Electric Moeller ABB Allen Bradley GE / AEG - Connection system: Single box terminal (only 1 conductor) from 40HP/ A50 up to 100HP/ A110 - Changing contacts: Contacts can only be changed from 40HP SIRIUS: Contactors can be changed from Size S2/ 20HP - Auxiliary contacts:Ie/ AC-15 (auxiliary contacts): 4A/ 230V SIRIUS: 6A/ 230V - Ambient temperature/operating range: Max. ambient temperature, +55°C / SIRIUS: +60°C  Operating range: 0.85 - 1.1xUs; at >55°C, restricted operating range up to 1xUs

  12. Contactors  100HP (3/3) + Dimensions: Compact small contactor B6/B7 (low depth) Schneider Electric Moeller ABB Allen Bradley GE / AEG + Auxiliary contacts:  1 integrated auxiliary contact as standard all the way up through to 30HP  From 40 to 60 HP, 6 front-mounted auxiliary contactors are possible

  13. 47,5 44 Contactors  75HP (1/3) Schneider Electric Moeller ABB Allen Bradley GE / AEG 54 54 72 100-M05/M09/M12 3 / 5 / 7.5HP 100-C09/C12/C16/C23 5 / 7.5 / 10 / 15HP 100-C30/C37 25 / 30HP 100-C43 40HP 100-C60/C72/C85 50 / 60 / 75HP S00 S0 S2 S3 3RT101 3RT102 3RT103 3RT104 3/5/7.5HP 5/7.5/10/15HP 20/25/30/40HP 50/60/75HP 45mm 45mm 55mm 70mm

  14. Contactors  45kW (2/3) - Coil terminals: Two-terminal coil: Connections top or bottom (separate Order Nos.) SIRIUS: 4-terminal coil Schneider Electric Moeller ABB Allen Bradley GE / AEG - Changing contacts:Contacts can only be changed from 75HP/ CAB6-85 onwards SIRIUS:Possible from Size S2/ 20HP - Dimensions:DC contactors: Very deep - Labeling:Rating plate data inadequate: - no connection cross-sections - no insulation stripping lengths - no tightening torques  The coil label cannot be read when the contactor is mounted SIRIUS: complete catalog number can be read from the font

  15. Contactors  75HP (3/3) - Screw mounting: The screws which are used to mount the contactor to the front panel are not captive screws Schneider Electric Moeller ABB Allen Bradley GE / AEG + Wye-delta starter: Space-saving design: Square footprint Safety contactors: Separate series of safety contactors 5 – 75HP (100S-C) - Positively-driven contacts SIRIUS: General - The contactor and auxiliary contact block are permanently coupled with one another SIRIUS: Special version with a Hischa block which cannot be removed - Protection against accidental/undesirable actuation SIRIUS: Accessory - Auxiliary contact, electronics/compatible in compliance with DIN 19240 SIRIUS: General

  16. 45 45 Contactors  100HP (1/3) Schneider Electric Moeller ABB Allen Bradley GE / AEG 55 66 75 LS02K/ 05 3 / 5HP LS4K/5K/7K/11K 5 / 7.5 / 10 / 15HP LS12K/15K/18K 20 / 25 / 30HP LS22K/30K/37K 40 / 50 / 60 HP LS45K/55K 75 / 100HP S00 S0 S2 S3 3RT101 3RT102 3RT103 3RT104 3/5/7.5HP 5/7.5/10/15HP 20/25/30/40HP 50/60/75HP 45mm 45mm 55mm 70mm

  17. Contactors  100HP (2/3) - Labeling:  No order designation [catalog number] on the front plate  Coil voltage cannot be read from the front  Rating plate: No data on the connection cross sections Schneider Electric Moeller ABB Allen Bradley GE / AEG - Coil terminals: Three terminal coil: Restrictions when directly mounting protective devices/ SIRIUS: 4-terminal coil

  18. Contactors  100HP (3/3) + Series:  Auxiliary contacts: 1NO/1NC integrated up to LS11K/ 15HP for 45mm wide (as version)  1NO+1NC can be snapped onto the front (2 individual blocks) as MRPD version from 30 to 100HP  Complete series of 4-pole contactors: Up to 10HP: 45mm side Schneider Electric Moeller ABB Allen Bradley GE / AEG + Connection system: Main and control circuits up to 100 HP are connected using ring cable lugs (this was presented at the Hanover Fair 2002) + Changing contacts: Contacts can be changed from 5HP / LS4K SIRIUS: this is possible from S2/ 25HP + Changing coils:Coils can be changed from LS02K (3HP) / LS05K (5HP)