1 / 35

Nye data – nye muligheder?

Nye data – nye muligheder?. Esben Auken , Anders V. Christiansen, Nikolaj Foged and Kurt Sørensen. HydroGeophysics Group Department of Earth Sciences, University of Aarhus, Denmark www.hgg.au.dk. Indhold. Hvordan ser x-data ud? Modelanalyser – motivationen

fineen
Télécharger la présentation

Nye data – nye muligheder?

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Nye data – nye muligheder? Esben Auken, Anders V. Christiansen, Nikolaj Foged and Kurt Sørensen • HydroGeophysics Group • Department of Earth Sciences, University of Aarhus, Denmark • www.hgg.au.dk

  2. Indhold • Hvordan ser x-data ud? • Modelanalyser – motivationen • Problemerne med måling af vinkel – “forurening” af x-signalet • Inversion

  3. Theoretical z-response z-component data Model 100 Wm 10 m 30 Wm 20 m 80 Wm 70 m 10 Wm

  4. Model 100 Wm 10 m 30 Wm 20 m 80 Wm 70 m 10 Wm Theoretical z- and x-response • Late time x ∞ t-3 • Late time z ∞ t-2.5 • x-component signal level is 5 – 8 times smaller than z-component x- and z-component

  5. Model Sensitivity Analysis – model 2 • White: z-component alone • Grey: x- and z-component • Black: x- and z-component, x with 60 kHz low-pass filter

  6. Model Sensitivity Analysis – model 1 • White: z-component alone • Grey: x- and z-component • Black: x- and z-component, x with 60 kHz low-pass filter

  7. Model Sensitivity Analysis – model 3 • White: z-component alone • Grey: x- and z-component • Black: x- and z-component, x with 60 kHz low-pass filter

  8. Location of first gate – 11 or 18 micros? • White: z-component alone • Grey: x- and z-component • Black: x- and z-component, x with 60 kHz low-pass filter

  9. The 3 Challenges for exploiting x-data • Signal to noise level • Altitude dependency • Natural background noise • “Contamination” of the x-data due to tilt of the Tx-frame • Timing of the instrumentation and measurement of the tilt

  10. Altitude Dependency x-data z-data Altitude: 1 m Altitude: 1 m

  11. Altitude Dependency x-data z-data Altitude: 1 m 18 m Altitude: 1 m 18 m

  12. Altitude Dependency x-data z-data Altitude: 1 m 18 m 29 m – operating altitude Altitude: 1 m 18 m 29 m

  13. The 3 Challenges for Exploiting x-data • Signal to noise level • x-signal is 5 – 8 times smaller than z-signal • x-signal decreases faster with altitude compared to the z-signal • x-noise is 5 – 10 times larger than z-noise • “Contamination” of the x-data due to tilt of the Tx-frame • Timing of the instrumentation and measurement of the tilt

  14. The 3 Challenges for Exploiting x-data • Signal to noise level • x-signal is 5 – 8 times smaller than z-signal • x-signal decreases faster with altitude compared to the z-signal • x-noise is 5 – 10 times larger than z-noise • “Contamination” of the x-data due to tilt of the Tx-frame • Timing of the instrumentation and measurement of the tilt

  15. x-component z-component Tilt – Normal Situation

  16. x-component z-contamination Positive Tilt of the Tx-frame • z-response adds signal to the x-response • The x-response caluclated as: Bxtotal = Bx + sin(Tilt) Bz

  17. ”Contaminated” x-response – Positive Tilt x-data Tilt: 0 deg

  18. ”Contaminated” x-response – Positive Tilt x-data 5 deg Tilt: 0 deg

  19. ”Contaminated” x-response – Positive Tilt x-data 10 deg 5 deg Tilt: 0 deg 9 usefull gates

  20. x-component z-contamination Negative Tilt of the Tx-frame • z-response subtracts from the x-response

  21. ”Contaminated” x-response – Negative Tilt x-data Tilt: 0 deg

  22. ”Contaminated” x-response – Negative Tilt x-data Tilt: 0 deg -5 deg

  23. ”Contaminated” x-response – Negative Tilt x-data Tilt: 0 deg -5 deg -10 deg 3 - 4 usefull gates

  24. The 3 Challenges for Exploiting x-data • Signal to noise level • x-signal is 5 – 8 times smaller than z-signal • x-signal decreases faster with altitude compared to the z-signal • x-noise is 5 – 10 times larger than z-noise • “Contamination” of the x-data due to tilt of the Tx-frame • The tilt of the frame adds or subtracts signal form the x-response • Addition of signal is preferred from subtraction of signal • Tilt must treated as an inversion parameter - it can not be measured with the desired accuracy • Does (probably) not need a priori information for the tilt • Timing of the instrumentation and measurement of the tilt

  25. The 3 Challenges for Exploiting x-data • Signal to noise level • x-signal is 5 – 8 times smaller than z-signal • x-signal decreases faster with altitude compared to the z-signal • x-noise is 5 – 10 times larger than z-noise • “Contamination” of the x-data due to tilt of the Tx-frame • The tilt of the frame adds or subtracts signal form the x-response • Addition of signal is preferred from subtraction of signal • Tilt must treated as an inversion parameter - it can not be measured with the desired accuracy • Does (probably) not need a priori information for the tilt • Timing of the instrumentation and measurement of the tilt

  26. Model x-data converted to apparent resistivity 100 Wm 10 m 30 Wm 20 m 80 Wm 70 m 10 Wm Front Gate in 7.8 µs Timing of the Front Gate Front Gate preventing the primary signal to saturate the receiver – opens for the signal just before the first time-gate

  27. Model 100 Wm 10 m 30 Wm 20 m 80 Wm 70 m 10 Wm Timing of the Front Gate 300 nSec shift corresponds to approx. 3 % shift of the first gate Front Gate preventing the primary signal to saturate the receiver – opens for the signal just before the first time-gate x-data converted to apparent resistivity Front Gate in 8.8 µs Front Gate in 7.8 µs

  28. The 3 Challenges for Exploiting x-data • Signal to noise level • x-signal is 5 – 8 times smaller than z-signal • x-signal decreases faster with altitude compared to the z-signal • x-noise is 5 – 10 times larger than z-noise • “Contamination” of the x-data due to tilt of the Tx-frame • The tilt of the frame adds or subtracts signal form the x-response • Addition of signal is preferred from subtraction of signal • Tilt must treated as an inversion parameter as it can not be measured with the desired accuracy • Does probably not need a priori information from the device • Timing of the instrumentation and measurement of the tilt • The timing is accurate within 200 nanosec - OK! • Accurate measurement of the tilt while flying

  29. Inversion Methodology • LCI – soundings

  30. Inversion Methodology • LCI – soundings

  31. Inversion Methodology • LCI – soundings

  32. Inversion Methodology • LCI – soundings

  33. Inversion Methodology • Damped least squares scheme, modeling of system transfer function • Low pass filters, front gate, turn-on and turn-off exponential ramps • Flight altitude and tilt are constrained parameters • The model is parameterized or smooth 1D

  34. Data

  35. Diskussion og konklusion • x-data tilfører information om den overfladenære geologi • Ved to-moment-system kompenserer x-data for, at første gate er i 16 microsek. • Ved ét-moment-system (første gate i 10 microsek.) tilfører x-data opløslighed i betragetligt omfang. • x-signalet kan anvendes, hvis ikke modstanden er for høj • Kræver at flyvehøjden er omkring 30 m (eller lavere) • Kræver nøjagtig måling af vinkel og kalibrering af instrumenterne • Giver ikke ekstra arbejde i felten, men giver ekstra processerings- og tolkningsarbejde • Stadigvæk på forskningsstadiet

More Related