V0-AND trigger cross section at 7 TeV p+p collisions by van der Meer scan method

V0-AND trigger cross section at 7 TeV p+p collisions by van der Meer scan method. ALICE Physics Forum, Sep. 1, 2010 Ken Oyama University of Heidelberg. Introduction. Interaction cross section of “process” fires V0-AND (V0-A & V0-C) trigger has been determined

finian
Télécharger la présentation

V0-AND trigger cross section at 7 TeV p+p collisions by van der Meer scan method

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. V0-AND trigger cross sectionat 7 TeV p+p collisionsby van der Meer scan method ALICE Physics Forum, Sep. 1, 2010 Ken Oyama University of Heidelberg

  2. Introduction • Interaction cross section of “process” fires V0-AND (V0-A & V0-C) trigger has been determined • Method: Van der Meer scan (Vernier scan) • measure rate of the trigger with different displacements of two beams • V0-AND trigger has been chosen because • back-ground free ( < few Hz ) • high efficiency ( > 80 % of total p+p cross section) • stable detector operation • Usage: • cross section normalization • luminosity measurements ALICE Physics Forum

  3. Basic of the Method beam intensities • Luminosity and cross section: • We don’t know beam profile but by displacing two beams by Dx and Dy  trigger rate directly gives the square average beam sizes number of bunches and machine freq. beam profiles Gaussian shape approximation beam sizes (g: normalized Gaussian) top rate ALICE Physics Forum

  4. Extracted Raw Data from DCS DB • Right: systematic decrease of luminosity and Left: magnified in time • Straight gray bold line (fit) is considered to be blow-up and correction has been performed (make it flat) ALICE Physics Forum

  5. Beam Condition • Single_2b_1_1_1one collision in ALICE • beta* = 2 m • Zero crossing angle • Colliding bunch intensities: N1 = 17.4 x 109 protons N2 = 20.6 x 109 protons • Intensity systematic error • measurement done by: • BCT (beam current transformer): bunch-by-bunch relative intensity • DCCT (DC current transformer) : absolute scale but for DC current • Systematic uncertainty is governed by offset of DCCT ~ 5% for each beam • LHC-wide systematic error • Intensity decrease … negligible (this is different from emittance increase) ALICE Physics Forum

  6. Pile-up Correction • At 1 kHz trigger rate : average number of “firing” times per bunch crossing is 1kHz / frev ~ 0.1  this is the  (Poisson average) Interaction rate Trigger rate  • Correction is as much as 5% at around top luminosity where R(0,0) ~1 kHz • V0-AND trigger is slightly biased as it is essentially multiplicity trigger however effect of that to the rate measurement is <<1% ALICE Physics Forum

  7. Corrected Data • Three different correction types tested • nc: no correction • pc: pile-up corrected • bc: pile-up + blow-up corrected ALICE Physics Forum

  8. Fitting Methods (Single & Double Gaussians) • In analysis note, of course, all fit results are presented • For y-scan, tail needs double gaussian, but for x-scan, it is not needed ALICE Physics Forum

  9. Comparison of All Combinations • More comparisons are given later stages • For double-Gaussian, “area sum method” (shown later) was used ALICE Physics Forum

  10. Area Sum Method • Not assume Gaussian for the beam shape (robust because of it) • Assume beam profile is factorized in x and y: • Rate: where sharpness is defined: • Scan area:  • because top rate R(0,0)=kbfrevN1N2QxQy ,  Luminosity and cross section can be obtained only by top-rate R(0,0) and Sx, Sy =1 ALICE Physics Forum

  11. Numerical Area Sum Method Results • Statistical error is over-estimated due to correlation between Sx,y and R(0,0) actual error is estimated to be below 1% ALICE Physics Forum

  12. Comparing All Methods • Different methods and corrections give as much as 1.8% of differences In RMS of the deviation from chosen center (sum. pc.). • chosen as final central value • no shape assumption • blow-up corr. makes nodifference • but also has no strong reason tells this is reasonable large statistical error is to be corrected (due to strongly correlated parameter for double-Gaussian fit for x-axis) ALICE Physics Forum

  13. Systematic Errors and Final Value • The largest uncertainty is the beam intensity (55%) • The second largest is the separation calibration (can be improved future) • Result V0-AND trigger  = 62.3 [mb] stat. uncertainty < 1% syst. uncertainty 8% Remarks • All other LHC experiments are dominated by the same beam intensity errors • STAR: syst. = 5.7% (Au+Au), dominated by beam current 22% [A.Drees et.al.] • Simulation gives ~61 [mb] … to be reviewed !! value may be updated with further scans ALICE Physics Forum

  14. Summary and Outlook • V0-AND trigger cross section has been measured using van der Meer scan method • Analysis note written (being checked by experts now) • Simulation needed to check the results • Value might be updated after all checks and also new scan • New scan being prepared • with CMUS1 and possibly EMCal triggers • with more systematic study (xu – yu – xd - yd, wire scan, and etc) • BCNWG (beam current normalization working group) is working for beam current, hopefully we get less systematic (Martino as behalf of ALICE) • DCCT baseline error can become small if beam current is larger • Larger intensity gives more pile-up (being discussed) • Large beta* helps • Acknowledgements G. De Cataldo, A. Di Mauro, C.Garabatos, and F. Antinori ALICE Physics Forum

  15. Backup … Bump Calibration 1 • Both beam-1 and beam-2 were displaced by ~80 m and even vertex displacement has been measured (Davide) ALICE Physics Forum

  16. Backup … Bump Calibration 2 • Fit result gives 2% of deviation in Dx,y scale put as systematic error [Davide, Antonello] ALICE Physics Forum

  17. Backup … To be prepared for new scan ALICE Scalars • Continue with V0-DCS scalar. • Single muon trigger (DMUS1) to be monitored • Other triggers? (EMC, INT1?) • Putting some triggers In interaction record? • V0 has no after pulse masking, but we can mask it offline • Can have 2 triggers • Can have multiple colliding bunches Beam Intensity (measured by BCT and DCCT) • This is the largest uncertainty • Dominated by DCCT (DC current transformer) offset More bunches or more bunch intensity decreases relative uncertainty • But more bunch intensity gives pile-up problem ALICE Physics Forum

  18. Backup … For Further Scans Requirements sent to LHC by Antonello Non-Invasive scan (after technical stop?), at least • One colliding bunch in ALICE • Double scan time at tail and increase steps around top (if possible) • Scan range: ± 3σ for each beam (± 5σ or more if possible) • Introduce background check with displaced beams before collapsing bumps • Introduce longitudinal scan • Separation calibration: ≥5 point, ~100K events/point • Wire scan then X-Y-X-Y (second scan in reverse direction), then separation, then new X-Y when emittance has grown (lower mu), or after wire scan? For dedicated scan, in addition to above • Better than 5% on intensity. N1,2= ~ 2x1010 protons • No x-angle, dipole ON • beta*=10 m or as large as possible (if scan range relative to beam size is ok) • Dump after last scan for DCCT baseline check  better uncertainty on intensity ALICE Physics Forum

  19. Backup … Treatment of Double-Gauss Fits In previous analysis • If you assume 2 Gauss as beam profile, it creates 2x2 Gauss overlapping area gives 3 different Gaussian due to crossing term  not consistent to double fit anymore • Proper way is to use the same as sum method (see last presentation) ALICE Physics Forum

More Related